System power consumption
The system power consumption of the router depends on the type and number of cards and the fan
tray power consumption.
•
The minimum system power consumption is the total static power consumption of all cards plus
the minimum fan tray power consumption. For example, for a CR16010-F (one fan tray) router
that has two CSR05SRP1L1 MPUs, two CSPC-XP4LB service modules, two CSFC-08B
switching fabric modules, and one fan tray, the minimum system power consumption of the
router is 2 × 46 + 2 × 53 + 2 × 44 + 13 = 299 W.
•
The maximum system power consumption is the total dynamic power consumption of all cards
plus the maximum fan tray power consumption. For example, for a CR16010-F (one fan tray)
router that has two CSR05SRP1L1 MPUs, two CSPC-XP4LB service modules, two CSFC-08B
switching fabric modules, and one fan tray, the maximum system power consumption of the
router is 2 × 53 + 2 × 80 + 2 × 60 + 300 = 686 W.
Heat dissipation
Heat dissipation is measured in BTU/h, and 1 W equals 3.4121 BTU/h.
The heat dissipation of a router depends on its power consumption. To calculate heat dissipation of
the router, assume 90% power consumption is converted to heat, and the efficiency of the power
supply is 90%. Heat dissipation/hour of the router is 0.9 × (total power consumption of the cards plus
power consumption of the fan tray)/0.9 × 3.4121.
For the power consumption of the cards and fan trays of the router, see
and system power
Environmental specifications
Table 8 Environmental specifications
Description
Temperature
Relative humidity
Noise
The router uses fan trays that can automatically adjust the fan speed to meet the cooling
requirements. The sound pressure level of the router varies by fan speed.
Table 9 Sound pressure levels
Model
CR16006-F
CR16010-F (one fan tray)
CR16010-F (two fan trays)
CR16010H-F
CR16010H-FA
consumption."
Operating
0°C to 45°C (32°F to 113°F)
10% RH to 95% RH, noncondensing
Sound pressure level under
normal temperature
62.3 dBA
61.6 dBA
65.7 dBA
66.4 dBA
66.4 dBA
Sound pressure level when the
fan trays operate at full speed
75.5 dBA
72.6 dBA
73.3 dBA
84.0 dBA
84.0 dBA
21
"Module power consumption
Non-operating
–40°C to +70°C (–40°F to +158°F)
5% RH to 95% RH, noncondensing
Need help?
Do you have a question about the CR16000-F and is the answer not in the manual?