Specifications; Appliance Operation; Transportation And Storage - Electrolux EIFH/C-2 EEC User Manual

Ptc heater
Hide thumbs Also See for EIFH/C-2 EEC:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
6
http://www.home-comfort.com

Specifications

Supply voltage, V ~ Hz
Maximum power consumption, kW *
3
Productivity, m
Rated current, A
Protection degree
Electrical protection class
Heating area, m
Appliance size (W×H×D), mm
Packing size (W×H×D), mm
Net weight, kg
Gross weight, kg
* Indicated is a guideline value and may differ depending on actual conditions of use.

Appliance operation

When using the device, observe the safety
requirements outlined in this manual.
Before turning on the fan heater, the switch key
must be in position "2", and the thermostat knob
must be turned to the extreme counterclockwise
position.
Fan heater control panel
1.
Mode "1", on (air heating and, depending
on the position of the thermostat, ventilation
without heating)
2. Mode "0" (off).
3. Thermostat.
Turning on the fan heater and operating modes
To turn on the fan heater, connect the mains
plug to the mains socket, set the switch button to
position "1" (mode "1"). If the ambient temperature
is higher than the one set by the thermostat, the
fan heater works in ventilation mode without
heating. If the ambient temperature is lower
than that set by the thermostat, the fan heater
operates in the ventilation mode with heating. The
thermostat knob sets the required air temperature
in the room. The thermostat maintains the set
Model
/h
2
*
EIFH/C-2 EEC
220–240 ~ 50
2.2
100
9.6
IP 21
I class
up to 25
150×180×170
180×150×160
1.1
1.2
temperature by automatically turning off and
on the electric heater (the approximate range
of the maintained temperature is from 0 to +40
°C). To increase the desired temperature, turn
the thermostat knob clockwise, to decrease -
counterclockwise.
Comfort mode
To set the required heating temperature and
maintain a constant room air temperature,
turn on the appliance at full power by moving
the thermostat control knob to the "max"
position. When the room temperature reaches
a comfortable level for you, slowly turn the
thermostat control knob counterclockwise until
you hear a click. Thus, the device will remember
the temperature that is comfortable for you and
will maintain it by automatically switching on and
off.

Transportation and storage

The device in the manufacturer's packaging
can be transported by all types of covered
transport with the exception of shocks and
movements inside the vehicle. The device
should be stored in the manufacturer's
packaging in a heated, ventilated room at
a temperature of +5 °C to +40 °C and an
average monthly relative humidity of 65% (at a
temperature of +25 °C).
After transportation at subzero temperatures,
it is necessary to keep the fan heater in
the room where it is supposed to be used
without being connected to the network for
at least 2 hours.
EIFH/C-3 EEC
220–240 ~ 50
3
150
13.6
IP 21
I class
up to 35
175×205×180
195×175×185
1.6
1.7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eifh/c-3 eec

Table of Contents