▶ Avoid skin or eye contact with refrigerant. manual. ▶ Seek medical attention if you get refrigerant on your skin or in your For operation, follow the instructions of the user eyes. manual. Table 2 Compress 3400i AWS – 6721852066 (2023/01)
▶ Do not connect any electrical supply to the circuit if a fault that can volume and the total output of the system, water treatment may be compromise safety is detected. required to avoid damage due to the formation of lime-scale. Compress 3400i AWS – 6721852066 (2023/01)
Page 5
/ cm. To prevent oxygen from entering the heating water, the expansion vessel must be adequately dimensioned. When installing diffusion open pipes, a system separation with the help of a heat exchanger is required. Compress 3400i AWS – 6721852066 (2023/01)
Bag with connectors for the installation module Outdoor temperature sensor [10] Screws (x2) and dowels (x2) for mounting bracket [11] Screws for drip tray (x4) [12] Copper pipe [13] Heating circuit flow temperature sensor [14] Drip tray Compress 3400i AWS – 6721852066 (2023/01)
Return from the heating system [10] Cable feed for power supply [11] Cable feed for sensor, CAN-BUS and EMS BUS [12] Refrigerant out to outdoor unit (liquid) [13] Refrigerant in from outdoor unit (gas) Compress 3400i AWS – 6721852066 (2023/01)
▶ Run the connector pipes for the heating system and cold/domestic hot water in the building up to the installation location of the indoor unit. Compress 3400i AWS – 6721852066 (2023/01)
Risk of personal injury and damage to property OR-S Using the incorrect sensors may lead to personal injury such as scalding as well as damage to property due to an excessively high or low Compress 3400i AWS – 6721852066 (2023/01)
14.Put the heating system into operation. Use the control unit to make the necessary settings ( instructions for control unit). 15.Check that all sensors display the appropriate values. 16.Check and clean the particle filter. Compress 3400i AWS – 6721852066 (2023/01)
▶ Use the drip tray screws to fix the drip tray to the bottom of the indoor unit, screw it on slightly. Do not overtighten as it can damage the drip tray. Observe the following figure for reference: 0010048274-001 Fig. 7 Assemble of the drip tray Compress 3400i AWS – 6721852066 (2023/01)
Flow pipe to heating system Refrigerant in from the outdoor unit (gas) Magnetic filter valve Refrigerant out to the outdoor unit (liquid) Return pipe from heating system Drain of the pressure relief valve and condensates Outdoor unit Compress 3400i AWS – 6721852066 (2023/01)
6. Continue filling until only water comes out of the outlet hose and the indoor unit according to the wiring diagram. bubbles no longer form in the heating system. Where appropriate, take additional measures to vent the heating system. 7. Close the drain valve VC2. Compress 3400i AWS – 6721852066 (2023/01)
Cable circuit for power circuit cables (230V/400V) Overheating protection (OHP) Relay 1,2 and 3 for electric booster heater When routing the electrical cables in and out of the electrical box, make sure they do not become strained. Compress 3400i AWS – 6721852066 (2023/01)
The contact on the component or relay that is connected to this input [Buzzer] Alarm buzzer (accessory) must be suitable for 5V and 1mA. [PW2] DHW circulation pump [PK2] Relay output, cooling mode, 230V~ [VW1]DHW 3-way valve [PC1] Heating circulation pump Compress 3400i AWS – 6721852066 (2023/01)
▶ Use cable with a minimum cross-section of 0.5 mm ▶ In case of external inductive interferences (e.g. from PV systems), use screened cables. Connect only one end of the cable shield to the nearest ground. Compress 3400i AWS – 6721852066 (2023/01)
Functions which are activated via the external inputs are described in the instructions for the control unit. The external input is either connected to a manual switch or a control device with a 5 V relay output. Compress 3400i AWS – 6721852066 (2023/01)
[1] 230V~ 32A, power supply for indoor unit [2] 230V~, controller (EMS modules) accessory [3] 230V~, power supply for heating cable (accessory) Power to the outdoor unit is supplied separately from the distribution board (230V~). Compress 3400i AWS – 6721852066 (2023/01)
8. Check the pressure on the pressure gauge GC1 and top up with the fill valve VW2 if needed. The pressure should be 0.3–0.7 bar above the pressure set in the expansion vessel. 9. Check that the heat pump is running and that there are no alarms. Compress 3400i AWS – 6721852066 (2023/01)
▶ Make sure that there are no current alarms (see instructions for the control unit). -or- ▶ Eliminate any faults according to the control unit instructions. ▶ Check the operating temperatures in accordance with the instructions for the control unit. Compress 3400i AWS – 6721852066 (2023/01)
19.Check the pressure at the pressure gauge GC1, if the pressure is less ▶ Screw the cap back on (hand tight). than 2bar top up via the filling valve VW2. ▶ Open the valve (5). Compress 3400i AWS – 6721852066 (2023/01)
▶ Connect the cable on the installation module to terminal EMS-BUS. If a component is already connected to the EMS terminal, establish the connection in parallel to the same terminal according to fig. 18. 0010012105-002 Fig. 18 EMS connection on the installer module Compress 3400i AWS – 6721852066 (2023/01)
2) Time per shower 3) Maximum tap flow 4) Maximum volume of water consumed during a shower for one time period and type of tap flow 5) Optimized cylinder volume to the domestic hot water consumption profile Compress 3400i AWS – 6721852066 (2023/01)
Fig. 20 Connection of the diverter valve VW1 on the installer module Fig. 23 Contact closed, connection A open During domestic hot water heating, the contact is closed and connection A is open. Fig. 21 Molex plug Compress 3400i AWS – 6721852066 (2023/01)
▶ Insulate all pipes and connections. ▶ Install the pool module ( Instructions for the pool module). ▶ Set the elapsed time of the swimming pool diverter valve during commissioning ( instructions for control unit). Compress 3400i AWS – 6721852066 (2023/01)
We use the best possible technology and materials for protecting the environment taking account of economic considerations. A WLAN router, internet connection and the Bosch HomeCom Easy app Packaging are required to use this product.
13<35 Electric booster heater Direct system open circuits bypass Electric booster heater Buffer >35 Direct system bypass On/off valves with no Buffer open circuits No open circuits and Serial buffer differential pressure Compress 3400i AWS – 6721852066 (2023/01)
Fig. 32 Outdoor unit with indoor unit and one heating circuit [1]Installed in the indoor unit. [5] Mounted on the wall. This hydraulic system is only envisaged for heating systems that comply with the requirements of flow, volume and pressure loss. Compress 3400i AWS – 6721852066 (2023/01)
Fig. 33 Outdoor unit with indoor unit, DHW and one or more heating circuits [1]Installed in the indoor unit [4] Mounted in the station or on the wall [5] Mounted on the wall PC1 and bypass are required in this hydraulic system ( Chapter 11.3.2). Compress 3400i AWS – 6721852066 (2023/01)
Fig. 34 Outdoor unit with indoor unit, buffer and one or more heating circuits [1]Installed in the indoor unit [4] Mounted in the station or on the wall [5] Mounted on the wall PC1 is required in this hydraulic system ( Chapter 11.3.2). Compress 3400i AWS – 6721852066 (2023/01)
Outdoor unit terminals Indoor unit Outdoor unit Control unit (user interface) Coding switch setting for A and P encoders (A=0, P=1) Installer module Room controller (accessories) EMS module (accessory) Connect-Key K 30 RF (accessory) Compress 3400i AWS – 6721852066 (2023/01)
The output of the electric booster heater must be limited to a maximum of 3.9kW with the configuration in parallel mode with the outdoor unit. • Electric booster heater in compressor mode: 1.95-3.9kW (K3 blocked) • Only electric booster heater, compressor off: 1.95-3.9-5.85kW Compress 3400i AWS – 6721852066 (2023/01)
The heating system has been filled according to the pressure determined in the expansion vessel to ..bar Yes | No Has the heating system been flushed before installation? Yes | No Has the particle filter been cleaned? Electric connection: Compress 3400i AWS – 6721852066 (2023/01)
▶ File completed maintenance protocol for refrigerant in a folder (log following criteria: book) Heat pump type: Serial number: Part number: Appliance index: Refrigerant / fill volume: Table 1 Maintenance protocol, heat pump information Maintenance carried out by: Contractor: Compress 3400i AWS – 6721852066 (2023/01)
Page 42
Table 1 Maintenance protocol, refrigerant (log book) Maintenance carried out by: Contractor: Refrigerant type: topped up? Refrigerant charge: recovered? Result of inspection: Next inspection due on: Signature, stamp Table 1 Maintenance protocol, refrigerant (log book) Compress 3400i AWS – 6721852066 (2023/01)
Page 43
Table 1 Maintenance protocol, refrigerant (log book) Maintenance carried out by: Contractor: Refrigerant type: topped up? Refrigerant charge: recovered? Result of inspection: Next inspection due on: Signature, stamp Table 1 Maintenance protocol, refrigerant (log book) Compress 3400i AWS – 6721852066 (2023/01)