Section 2 Disassembly; Disassembly Flow - Sony ICD-LX30 Service Manual

Memory card recorder
Hide thumbs Also See for ICD-LX30:
Table of Contents

Advertisement

ICD-LX30
This set can be disassembled in the order shown below.
2-1.

DISASSEMBLY FLOW

SET
2-2. CASE (REAR) BLOCK
(Page 4)
2-3. BATTERY BOX BLOCK
(Page 5)
Note: Follow the disassembly procedure in the numerical order given.
2-2.
CASE (REAR) BLOCK
3 two foots
4 two screws
– Rear bottom view –
Note: Please spread a sheet under a unit
not to injure case (front).
4
SECTION 2
DISASSEMBLY
2-4. ENCLOSURE BLOCK
(Page 6)
2-5. MAIN BOARD
(Page 7)
1 foot (L)
4 screw
7 Remove all claws while rounding in outer.
5 Insert the jig in the space between the
case (front) block and the case (rear)
block and remove.
2 foot (R)
4 screw
6 claw
6 claw
8
JIG
When disassembling the set, use the following jig.
Part No.
9-913-402-33
6 three claws
9 case (rear) block
6 claw
6 two claws
– Rear bottom view –