The meter is a static water meter based on the ultrasonic principle. The water meter has been developed on the basis of Kamstrup's experience since 1991, with development and production of static ultrasonic meters.
Configuration (with logo (15 x 38 mm) information on display Dynamic range & resolution, encryption software version level etc.) logo (15 x 38 mm) Pressure stage and Classifications protection class Marking and approval Kamstrup A/S •Technical Description • 5512-897_J1_GB • 06.2016...
OIML R49 with the with ‘FORCE Certification’ as notified body. OIML: ‘International Organization of Legal Metrology’) Please contact Kamstrup A/S for further details on national approvals and verification. (Also see next page) Kamstrup A/S •Technical Description • 5512-897_J1_GB • 06.2016...
Page 9
Inmetro and Mounting position: ANATEL Horizontal or vertical. approval marks Ambient class (OIML): B / C (in-/out-doors) Environment class: -Electromagnetic: E1 /E2 Certificado de Homologacões Ambient temperature: N° 3684-14-8657 Fluid temperature: 1...40 °C Kamstrup A/S •Technical Description • 5512-897_J1_GB • 06.2016...
Fulfils MID class E1 and E2 3.3 Materials Meter housing and meter pipe Polyphenylene Sulfide (PPS) with 40 % fibreglass Reflectors Stainless steel, W.no. 1.4306 Cover Glass Top ring Top ring (sealing) Polycarbonate (dyed) Kamstrup A/S •Technical Description • 5512-897_J1_GB • 06.2016...
0 °C – 20 °C ± 1 °C 20 °C – 30 °C ± 2.5 °C > 30 °C – No valid measurement Ambient/meter temperature: -5 – 55 °C ± 1 °C (Temperature in the meter housing) Kamstrup A/S •Technical Description • 5512-897_J1_GB • 06.2016...
1:100 G1B (R¾) 1:250 G1B (R¾) 1:100 Meter type Hot water meter, T70, T30/70 (OIML R49) Cold water meter, T30 or T50 (MID) Country code (language on label etc.) Numbers or letters Kamstrup A/S •Technical Description • 5512-897_J1_GB • 06.2016...
G¾B (R½) G1B (R¾) G1B (R¾) G1B (R¾) Meter type Cold water meter, T30 or T50 (MID) Country code (language on label etc.) Numbers or letters ZA = Republic of South Africa Kamstrup A/S •Technical Description • 5512-897_J1_GB • 06.2016...
G¾B (R½) 1:250 G1B (R¾) 1:250 Meter type Hot water meter Cold water meter Country code (language on label etc.) Numbers or letters AC = Australia Central AE = Eastern AW = Western Kamstrup A/S •Technical Description • 5512-897_J1_GB • 06.2016...
G1B (R¾) 1:250 Meter type Hot water meter Cold water meter Country code (language on label etc.) Numbers or letters MC = Mexico Central MM = Mexico Mountain MP = Mexico Pacific Kamstrup A/S •Technical Description • 5512-897_J1_GB • 06.2016...
Battery C-cell Meter size [m³/h] Connection Length [mm] Dynamic range G¾B (R½) 1:250 G1B (R¾) 1:250 Meter type Cold water meter Country code (language on label etc.) Numbers or letters CL = Chile Kamstrup A/S •Technical Description • 5512-897_J1_GB • 06.2016...
Country code (language on label etc.) Numbers or letters BB = GMT offset -3 BA = GMT offset -4 BF = GMT offset -5 Accessories An overview of suitable accessories are shown in the document: ‘Accessories List 5810-1270’ Kamstrup A/S •Technical Description • 5512-897_J1_GB • 06.2016...
Type: A / D (B / C) and 1 H (J ) and 3 Type: G (F ) and 2 L (M) and 4 Type U Type E / N (K / P) Kamstrup A/S •Technical Description • 5512-897_J1_GB • 06.2016...
When mounting the water meter, you must ensure that the length of the meter thread will not prevent sufficient tightening of the sealing surface, and make sure that PN10 or PN16 connections are used. Kamstrup A/S recommends EPDM-gaskets for cold water installations and PTFE-gaskets for hot water installations. Kamstrup A/S supplies such gaskets.
Page 33
Installation conditions As mentioned above the use of new gaskets in original quality is of crucial importance. The sealing surface of the threaded connection must be clean and level ALWAYS use new gaskets. Kamstrup A/S •Technical Description • 5512-897_J1_GB • 06.2016...
Page 34
In such cases, Kamstrup A/S recommends to install the meter by means of a special coupling with telescopic function. The coupling can be displaced up to 17 mm – to be able to compensate for differences and inaccuracies of pipe installations, both in the longitudinal direction and, to lesser extent, also against oblique’...
(MID) 2004/22/EC and OIML R49. A straight inlet section will only be necessary in case of heavy flow disturbances before the meter. Recommended water meter position Recommended water meter position Recommended for well installation. Air build-up may occur The meter functions optimally, but the display is ‘upside down’ Kamstrup A/S •Technical Description • 5512-897_J1_GB • 06.2016...
Receiving the Wireless M-bus signal, emitted at intervals of 16 or 96 seconds, depending on the meter configuration • Reading via the optical eye, e.g. by means of Kamstrup A/S’ wireless optical reading head, or optical reading head with USB connector. 10.2 Volume measurement The meter calculates water flow currently according to a fixed measuring cycle.
These are sent via the Wireless M-Bus radio signal. The temperature values, can be combined, as described in section ‘Optional register in data logger’. See more about temperature reading accuracy in the section ‘Temperature measurements - water and ambient/meter’. Kamstrup A/S •Technical Description • 5512-897_J1_GB • 06.2016...
Page 38
During periods of very low water consumption, the water temperature approaches the ambient temperature. During periods without water flow the weighted average cannot be calculated, and then a code 128 is stored, indicating that there is no consumption. Kamstrup A/S •Technical Description • 5512-897_J1_GB • 06.2016...
Note! R-value 1 + 2 are not an option for flowIQ® 2103 See description of Wireless M-Bus signal in section ‘Wireless M-Bus’ R-value ‘1’ and ‘2’ are not available for 2103 Kamstrup A/S •Technical Description • 5512-897_J1_GB • 06.2016...
99,999.999. The table below shows an overview of modes and readings: Normal mode Verification mode V1HighRes Data register Unit Number of digits Decimals after point 0-1-2 or 3 Kamstrup A/S •Technical Description • 5512-897_J1_GB • 06.2016...
Page 41
In ‘normal mode’ they flash once a second. In ‘verification mode’ they flash twice a second. Below you see the shift between the two dots: Kamstrup A/S •Technical Description • 5512-897_J1_GB • 06.2016...
Page 42
This means that there will not be any hours without flow, and the water meter will set an alarm for this 24-hour period. Users and water utilities must therefore, be critical of the leakage alarm. Kamstrup A/S •Technical Description • 5512-897_J1_GB • 06.2016...
Page 43
The Wireless M-Bus signal comprises the BURST code. If the BURST code is active, or has been active within the latest 30 days, a time indicator, with seven time intervals, will indicate how long the info code has been active. Kamstrup A/S •Technical Description • 5512-897_J1_GB • 06.2016...
Page 44
The Wireless M-Bus signal includes the code REVERSE. If the code REVERSE is active or has been active within the latest 30 days, a time indicator with seven time intervals will indicate how long the info code has been active. Kamstrup A/S •Technical Description • 5512-897_J1_GB • 06.2016...
Page 45
Info code – RADIO OFF (transport mode) This info code is active in the display when the water meter leaves Kamstrup A/S, and indicates, that the meter is still in ‘transport mode’ and that the built-in Wireless M-Bus radio transmitter has not yet been activated.
MULTICAL® 21 & flowIQ® 2101 /..02 /..03 As long as no adjustments have been made, both the ‘A’ and the digit are inactive, and Kamstrup A/S does not add further adjustment marking to the meter. After the first adjustment, ‘A’ activates, and the digit shows the number of adjustments (1 to 9).
Page 47
If the meter is configured for Wireless M-Bus mode T1 OMS, data transmission will only take place every 15 minutes – four times per hour. Kamstrup does not offer reading devices for Wireless M-Bus mode T1 OMS. Kamstrup A/S •Technical Description • 5512-897_J1_GB • 06.2016...
Verification mode 0.5 sec. For Kamstrup’s optical reading head a holder is available, which fits the water meter, and is clicked onto the meter. A picture of the optical head placed on the meter can be seen in section: ‘Pulse Interface for MULTICAL® 21 / flowIQ® 2101 / ..02 / ..03’...
The hour counters can not be accessed directly, but are represented in the info register in coarse resolution. See paragraph ‘Info register’ No hours are been counted as long as the meter is in ‘transport mode’. Kamstrup A/S •Technical Description • 5512-897_J1_GB • 06.2016...
The hour counters (for the four info codes), are represented by the last 12 bits apportioned with 3 bits each, as shown below. 15 14 13 12 11 10 9 BURST LEAK REVERSE Kamstrup A/S •Technical Description • 5512-897_J1_GB • 06.2016...
Page 51
It appears that BURST has been active for 1-8 hours and LEAK has been active for between 15 and 21 days. Furthermore, DRY has been active for 2-3 days within the latest 31 days. Kamstrup A/S •Technical Description • 5512-897_J1_GB • 06.2016...
When the meter switches to ‘verification mode’, the wireless M-Bus radio transmitter turns off. At the same time, a time-out starts. When the time-out period has expired the meter switches back to normal mode. The time-out period is 9 hours. Kamstrup A/S •Technical Description • 5512-897_J1_GB • 06.2016...
The meter is initially verified from the factory. A new factory adjustment requires disassembling of the meter and can only be carried out by Kamstrup A/S. When the meter has been locked it is only possible to make a percentage correction of the flow curve at three individual points. This is called re-adjustment.
Page 54
Naturally, this number must be identical with the number (AX) in the meter’s display. Below, samples on: Re-verification label Label used at control testing (meters not approved for re-verification) Kamstrup A/S •Technical Description • 5512-897_J1_GB • 06.2016...
Flow sensor manufacturers have been working on alternative techniques to replace the mechanical principle. Research and development at Kamstrup has proven that ultrasonic measuring is the most viable solution. Based on microprocessor technology and piezo ceramics, ultrasonic measuring is not only accurate but also reliable.
Page 56
To minimize the influence from variations of the velocity of sound in water, the latter is measured via absolute time measurements between the two transducers. These measurements are subsequently in the Kamstrup A/S •Technical Description • 5512-897_J1_GB • 06.2016...
The measurement is therefore a 'snapshot' of the current flow. This, like any type of digital sampling, integrates the measurements over time, leading to the calculation of the final volume. Flow [l/sec.) Time [seconds) Kamstrup A/S •Technical Description • 5512-897_J1_GB • 06.2016...
The meter has no functional limitations during the period, when the meter operates above this limit. Please note, however, that high flow velocities > Q (Max flow) involve the risk of cavitation, especially at low static pressures below 0.03 MPa (0.3 bar). Kamstrup A/S •Technical Description • 5512-897_J1_GB • 06.2016...
Cable type: length approx. 1.5 m – sleeves on cable ends. o Permitted cable length in total, maximum 30 meters. The Pulse Adapter can be used for MULTICAL® 21 / flowIQ® 2101/..02/..03 – SW revision H1 and forward. Kamstrup A/S •Technical Description • 5512-897_J1_GB • 06.2016...
1. Unfasten the screw of the adapter ring to allow mounting of the unit on the meter 2. Dismount the two screws at the top and remove the cover 3. Push the button on the PCB, which is placed under the cover (see figure below) Knap Button Kamstrup A/S •Technical Description • 5512-897_J1_GB • 06.2016...
The acquisition unit must have built-in ’pull-up’ – shown in figure below – to ensure correct voltage level of the pulse. The pulse output is two-wired and must be connected as follows: Opsamlingsenhed Acquisition unit Pull-up Sketch for connection of Pulse Adapter Kamstrup A/S •Technical Description • 5512-897_J1_GB • 06.2016...
Page 62
The connection marked ‘-‘ must be connected to the receiver's GND level. The connection marked ‘+’ should be connected to a pull-up resistor of an appropriate size, so that the maximum limits, shown in the table above, are met. Kamstrup A/S •Technical Description • 5512-897_J1_GB • 06.2016...
The supply for terminals 1 and 2 and the supply connected to the Pull-Up do not need to be the same or at the same level. The connection of the 8-pole plug J1, is indicated in figures below/next page. Kamstrup A/S •Technical Description • 5512-897_J1_GB • 06.2016...
Page 64
MULTICAL® 21 & flowIQ® 2101 /..02 /..03 14.1.1 Connection with pulse receiver without supply Here external supply for Pull-up is required 14.1.2 Connection with pulse receiver with supply Here the supply from the receiver can be used. Kamstrup A/S •Technical Description • 5512-897_J1_GB • 06.2016...
15.2 RADIO OFF Radio transmission interrupts if ‘RADIO OFF’ displays. RADIO OFF activates at the end of the production process at Kamstrup. The meter removes RADIO OFF automatically, when the volume register has counted water consumption for approx. 5 seconds.
Get further information and technical details on METERTOOL/LogView in the document: 5512-1653_GB ’Technical Description for METERTOOL & LogView ’ Kamstrup A/S •Technical Description • 5512-897_J1_GB • 06.2016...
19 Disposal Kamstrup A/S holds an environmental certification according to ISO 14001, and as part of our environment policy we use materials, which can be recovered environmentally correct to the greatest possible extent. • Disposal by Kamstrup A/S Kamstrup A/S accepts worn-out meters for environmentally correct disposal according to previous agreement.