Download Print this page

Amphenol Temposonics G Series User Manual

Linear position sensor analog and digital pulse outputs
Hide thumbs Also See for Temposonics G Series:

Advertisement

Quick Links

Magnetostrictive Position Sensors
Analog and Digital Pulse Outputs
Temposonics Model GP
Figure 1 - G-Series Connector Pin-Outs
4
5
6
3
1
2
Integral Connector (D6 Male)
(As viewed from end of sensor)
O O p p t t i i o o n n D D 6 6 0 0
1
9
7
5
3
2
10
8
6
4
In-line RB connector
O O p p t t i i o o n n R R B B _ _
A
H
B
G
C
K
J
F
E
D
In-line MS connector
O O p p t t i i o o n n F F M M _ _
Temposonics
G-Series Linear Position Sensor
User's Manual
®
Temposonics Model GH
Connection Options
Temposonics G-Series sensors are preconfigured at the factory by model
code designation. If needed, a variety of retrofit and replacement options are
available to provide direct backwards compatibility for your application.
G G - - S S e e r r i i e e s s s s e e n n s s o o r r c c o o n n n n e e c c t t i i o o n n o o p p t t i i o o n n s s : :
• Integral 6-pin DIN male connector, (option "D60")
• Integral cable with pigtail end, standard type (option "R _ _" ), and
heavy duty type (option "F _ _" )
• Integral cable with in-line RB type male connector (option "RB _" )
• Integral cable with in-line MS type male connector (option "FM _" )
Depending on the sensor output selected (Analog, Digital Pulse, or Neuter )
the different wiring required for the applicable combinations are shown in
Tables 1-3. Pin-outs for the above connector types are illustrated in Figure 1.
Notices used in this user's manual
N N o o t t e e s s : :
These notices provide important tips, guidance or advice.
I I m m p p o o r r t t a a n n t t : :
These notices provide information that might help you avoid inconvenient or problem
situations.
C C a a u u t t i i o o n n : :
These notices indicate situations that can be potentially hazardous to you. A caution
notice is placed just before a description of a potentially hazardous procedure, step or
situation.
All specifications are subject to change. Please contact MTS for specifications that are critical
to your needs. For additional information go to www.mtssensors.com.
550966 B

Advertisement

loading
Need help?

Need help?

Do you have a question about the Temposonics G Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Amphenol Temposonics G Series

  • Page 1 Temposonics ® Magnetostrictive Position Sensors G-Series Linear Position Sensor 550966 B Analog and Digital Pulse Outputs User’s Manual Temposonics Model GP Temposonics Model GH Connection Options Figure 1 - G-Series Connector Pin-Outs Temposonics G-Series sensors are preconfigured at the factory by model code designation.
  • Page 2 G-Series Wiring/Connections Table 1 - Analog Output Connections (Voltage or Current) Integral cable In-line Integral In-line Notes: wire color connector connector connector Function (Note 1) R_ _ or F FM_ pin no D60 pin no. RB_ pin no. 1. The format used to show the voltage and current output range is: [Value at 0 to 10, -10 to +10 Vdc, or Null (Setpoint 1)] to [Value at Span...
  • Page 3 Programming & Diagnostics G-Series LED Diagnostic Codes G-Series sensor red and green LEDs are intended to provide basic visual feedback for normal sensor operation and troubleshooting. These LEDs are located at the end of the sensor where the cable or connector is terminated. The green LED is used to indicate power applied and normal operation while the red LED is used to indicate programming mode operation and errors.
  • Page 4 G-Series PC Setup Software The G-Series PC setup software is intended to provide the most comprehen- Figure 2 - Hardware Connections for the PC Setup Software sive sensor monitoring and programming user interface available for this product line. Using this program, it is possible to modify sensor parameters PN 380077 G-Series sensor Converter...
  • Page 5 Programming & Diagnostics Using a PDA - G-Series Digital Pulse Output Sensors Only. Using the G-Series infrared (IR) interface, users can program G-Series Software can be found on “G-Series Documentation and Software” CD ROM digital-pulse sensors using a Personal Digital Assistant (PDA). The PDA (part no.
  • Page 6 Programming & Diagnostics Using a PDA - G-Series Digital Pulse Output Sensors Only. Reading Sensor Parameters (See Figure 4) Using the PDA configuration program it is possible to read the sensor Figure 4 - Selecting Sensor Parameters parameters listed in Appendix A on page 8. To view these parameters or sta- tus variables, in the PDA screen select Select Items Here (just under the Display box Begin Prog button) and select one of the individual parameters on the scrolling...
  • Page 7 Setpoint Programming with the Infrared Setpoint Programmer - G-Series Analog Output sensors only Using the MTS IR Setpoint Programmer it is possible to adjust the G-Series Hardware setup notes: : Analog sensor output at the ends of stroke for the Null (Setpoint 1) and Span (Setpoint 2).
  • Page 8 Fax: +49 / 23 51 / 56 491 Fax:+ 81 (42) 775.5512 800-498-4442 www.mtssensor.de © 2022 Temposonics, LLC – all rights reserved. Temposonics, LLC and Temposonics GmbH & Co. KG are subsidiaries of Amphenol Corporation. Except for any third party marks for www.mtssensors.com www.mtssensor.co.jp info@mtssensor.de which attribution is provided herein, the company names and product names used in this document may be the registered trademarks or unregistered trademarks of Temposonics, LLC or displacement@mtssensors.com...

This manual is also suitable for:

Temposonics gpTemposonics gh