Although every commercially reasonable effort has been taken to ensure the quality and accuracy of the information, Gallagher Group makes no representation as to its accuracy or completeness and it should not be relied on as such. To the extent permitted by law, all express or implied, or other representations or warranties in relation to the information are expressly excluded.
The Biometric Integration feature provides the ability for Morpho biometric readers to be connected to Gallagher Command Centre and configured as hardware items, for the purpose of biometric identification.
The Biometric Dongle Driver must be installed on the Command Centre server and any workstation that will be capturing biometrics. Either of the following dongle drivers work with Gallagher Command Centre: - SafeNet Dongle: USB VERIF (Part No. C864401) or USB IDENT (Part No. C864403/C864405) - Morpho ACS Dongle: V2 USB VERIF (Part No.
Factory Sigma Readers with Firmware 4.5.1 default to MA5G mode. Sites using Command Centre versions older than vEL7.80 will need to change the Sigma Reader firmware to MA2G4.5.1 (Legacy Mode) firmware. Please contact Gallagher Technical Support for assistance if any issues arise. • 6.2.1 Legacy Morpho Readers...
• 12 VDC supply with a minimum of 2.5 Amp. At 12 VDC (30 watts) IMPORTANT: It is important NOT to connect the MWC Terminal to the Gallagher Controller or URI 12VDC output. The current requirements of the MWC exceeds the 12VDC supply from Gallagher hardware.