To avoid possible electrical shock, turn the electricity off at the main fuse box before wiring. If you feel you do not have enough electrical wiring experience, contact a licensed electrician.
Incorrect wire connections will damage this receiver.
To reduce the risk of fire or injury, do not use this product in conjunction with any variable (rheostat) wall control.
NOTE: The battery will weaken with age and should be replaced before leaking takes place as this will damage the hand unit. Dispose of the used battery properly, keep the battery out of the reach of children.
The supplier warrants the remote control and receiver to be free from defects in workmanship and material present at time of shipment from the factory for a period of one year after the date of purchase by the original purchaser. To obtain warranty service, you must present a copy of the receipt as proof of purchase. All costs of removing and reinstalling the product are your responsibility.
Contact the Customer Service Team at 1-855-HD HAMPTON or visit www.HAMPTONBAY.COM
Part | Description | Quantity |
A | Remote control | 1 |
B | Receiver | 1 |
C | AAA 1.5V battery | 2 |
D | Plastic wire connector | 5 |
E | White painting screw | 1 |
F | Rubber isolated pad | 2 |
This product and/or components are governed by one or more of the following U.S. Patents: 5,947,436; 5,988,580; 6,010,110; 6,046,416, 6,210,117 and other patents pending.
NOTE: The frequencies on your receiver and hand unit have been preset at the factory. Before installing the receiver, make sure the dip switches on the receiver and hand unit are set to the same frequency. The dip switches on the hand unit are located inside the battery compartment.
NOTE: The battery will weaken with age and should be replaced before leaking takes place as this will damage the hand unit. Dispose of the used battery properly, keep the battery out of the reach of children.
NOTE: It is imperative that the code used for both transmitter and receiver is exactly the same, otherwise remote controller will not work.
To reduce the risk of fire or electric shock, remember to disconnect power. The electrical wiring must meet all local and national electrical code requirements. The electrical source and fan must be 110/120 volt, 60Hz. Do not use this product in conjunction with any variable wall control. Incorrect wire connection can damage this receiver.
If fan or house wires are a different color, have this unit installed by a licensed electrician.
Do not install in a damp location or immerse in water (For indoor use only). Do not pull on or cut leads shorter. Do not drop or bump the unit.
NOTE: The ceiling fan must be set at HIGH speed and light kit (if installed) should be set to the ON position.
NOTE: For better performance with the WINK system, the T-Shaped antenna stick should be mounted to the ceiling outside of the fan's ceiling canopy using the pre-mounted doublestick tape and wood screw (included).
To avoid possible electrical shock, turn the electricity off at the main fuse box before wiring. If you feel you do not have enough electrical wiring knowledge or experience, contact a licensed electrician.
Each wire not supplied with this fan is designed to accept up to one 12-gauge house wire and two wires from the fan. If you have larger than 12-gauge house wiring or more than one house wire to connect to the fan wiring, consult an electrician for the proper size wire nuts to use.
Use the wire connecting nuts (AA) supplied with your fan. Secure the connectors with electrical tape and ensure there are no loose strands or connections.
Use the wire connecting nuts (AA) supplied with your fan. Secure the connectors with electrical tape and ensure there are no loose strands or connections.
- Press and release the
button to turn the fan on or off.
Press and hold the button for 3 seconds to use the "walk away time delay"; this will activate the light for 30 seconds (if you are using dimmable bulbs the light will be activated at 50% brightness.
- Fan Speed - LED's on the fan speed button will illuminate to the corresponding speed.
- Press button once - turns the fan on high speed.
- Press button twice - turns the fan on medium-high speed.
- Press button three times - turns the fan on medium-low speed.
- Press button four times - turns the fan on low speed.
Press button five times - fan will turn off.
- Light ON/OFF
Press and release the button to turn the light on or off.
If you are using dimmable bulbs and you have previously set the dip switch in your remote control to the "D" position, press and hold the button to activate the dimmer function.
- Comfort Breeze - Press and release the
button to enable Comfort Breeze TM; this will change your fan speed randomly, simulating a relaxing breeze. To cancel this feature press
or
.
- Timer
- While the fan is on press button once - turns on a 2 hour run timer.
- While the fan is on press button twice - turns on a 4 hour run timer.
- While the fan is on press button three times - turns on a 8 hour run timer.
NOTE: Be sure your WINK Hub is plugged in and within range of your fan. Refer to Wink HUB user manual for the range.
NOTE: If using a dimmer with these lights, set dimmer at highest setting for best results.
NOTE: Reset your fan if the pairing is taking longer than expected. Turn off your fan for 3 seconds, then turn it back on for 3 seconds. Repeat these steps 5 times. The light will blink 3 times when factory reset is successful. If the pairing failed, please reset the device to original setting and re-start the pairing.
When on "fan control screen," press settings button in upper right corner to display the settings panel.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
Any changes or modifications not expressly approved by the grantee of this device could void the user's authority to operate the equipment.
FCC ID: KUJCE10406, KUJCE10407
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Download HAMPTON BAY Ceiling Fan Remote Control 99432 Manual
Advertisement
Need help?
Do you have a question about the 99432 and is the answer not in the manual?
Questions and answers