General Requirements
General

2.4 Space and Floor-Loading Requirements

This paragraph provides the principal characteristics of the system (see figs.
2.1 to 2.3 and the tabels below).
The minimum access clearance mentioned in the following paragraphs relates
to the space needed both for servicing and/or operation.
Depth, without feeders
Depth, with tape feeders, max. size tape reel, and
tape feeder retracted
Width
Maximum height (with feet set max.)
Minimum ceiling height
MINIMUM ACCESS CLEARANCE (mm)
Rear/Front
Left/Right (in case of stand alone)
MINIMUM OVERALL FLOOR SPACE
For siting, operation and service ;
in line, without CSM Trayfeeder
stand alone, without CSM Trayfeeder
in line, with CSM Trayfeeder
stand alone, with CSM Trayfeeder
Weight CSM III
Weight CSM Trayfeeder
Supporting feet (fig. 2.3) for both the
CSM III and CSM Trayfeeder
Average floor loading (over 4 feet)
CSM III
CSM trayfeeder
Floor loading per foot
CSM III
CSM Trayfeeder
Floor requirements
Pre-installation Manual CSM 66/84/84V III
PA 1306/40 /50 /60 /61
Requirements
OVERALL DIMENSIONS (mm)
1440
2140
1600
1860
2200
1000
1000
4140 x 1600 mm
4140 x 3600 mm
refer to fig 2.1
4140 x 3600 mm
approx. 600 kg
approx. 100 kg
4 adjustable feet (range
35 mm)
4
2
55.6 x 10.
N/m
4
2
9.28 x 10.
N/m
4
2
13.9 x 10.
N/m
4
2
2.32 x 10.
N/m
Supporting feet must rest
directly on a concrete
floor or on steel plates
250 x 250 x 10 mm.