E-Mail: info@digitize-inc.com Website: http://www.digitize-inc.com This manual has been prepared by DIGITIZE, INC. for use by its licensees, distributors and customers. The information contained herein is the property of DIGITIZE, INC. and may not be copied, disclosed or reproduced, in whole or in part, without the prior written approval of DIGITIZE, INC.
LED INDICATORS SPECIFICATIONS 1.9.1 CURRENT CONSUMPTION 1.9.2 DEMENSIONS 1.10 APPLICABLE PUBLICATIONS SECTION 2 PROGRAMMING THE DET-6B/12B EPROM DIGITIZE, INC. DET-6B/12B PROGRAM DATA LOCATIONS PROCEDURE FOR USING THE DET-PROG PROGRAMMER 2.2.1 TIMING AND OPTIONS 2.2.2 SET TELEGRAPH CODES SECTION 3 INSTALLATION...
The DIGITIZE Electronic Transmitter, Six Zone (DET-6B) is a solid-state microprocessor coder for use over telegraph hard wire. The DET-6B is designed to operate with a loop current from 50 mA to 750 mA. A dual 6-zone version (DET-12B) is available in a larger enclosure.
Codes for either a short or open line condition at the input zones. The DET-12B uses 2 of the 6 zone boards. When a zone input goes into Alarm, the DET-6B/12B will send the code number for the unit followed by the code that was selected for the zone that went into Alarm.
EPROM. The standard value on the Master EPROM is 1/4 second, with a value of 06, which represents approximately 6/24. See page 2-3, location 7B3 for calculation. EPROM 27C512 A blank 27C512 EPROM is supplied with each DET-6B. The 27C512 EPROM is programmed using Digitize DET-PROG programmer. The DET-12B is supplied with 2 EPROMS.
DET-6B/12B INSTALLATION AND OPERATION MANUAL 1.10 APPLICABLE PUBLICATIONS National Fire Protection Association (NFPA) standards 72 proprietary, 1221. DIGITIZE, INC. 700158-0000 REV.F 02/16...
SECTION 2 PROGRAMMING THE DET-6B/12 EPROM The DET-6B is supplied with one 27C512 EPROM for the storing of the data, which is to be transmitted when any input is activated. A DET-12B is supplied with two EPROMS. In order to program the DET-6B/12B EPROM for operation, the information can either be sent to DIGITIZE, INC with the purchase order for the DET-6B/12B or programmed using the DET-PROG EPROM programmer for the PC.
Page 12
DET-6B/12B INSTALLATION AND OPERATION MANUAL ALARM CODES TROUBLE CODES ADDRESS USER ADDRESS USER 789 Zone 1 78F Zone 1 78A Zone 2 790 Zone 2 78B Zone 3 791 Zone 3 78C Zone 4 792 Zone 4 78D Zone 5...
Page 13
DET-6B/12B INSTALLATION AND OPERATION MANUAL ADDRESS DESCRIPTION USER Choice of Bulldog option_________ 01 = YES (transmits over any unit_______ on the line) (No PNIS) 00 = NO (has PNIS) Buzzer activation time. 00 to 9.9 in tenths. (40 = 4.0 minutes, standard)
Page 14
DET-6B/12B INSTALLATION AND OPERATION MANUAL The following code number locations contain five digits followed by 00. If a box contains less than five digits, fill the balance of the box number with 00’s. The sixth digit is always 00. For example, Box 123 is represented by 1, 2, 3, 00, 00, 00.
DIGITIZE’s only responsibility will be to reprogram another chip if there is an error on our part. This information can be loaded by someone other than DIGITIZE, INC by using the DET-6 EPROM Programmer for the PC.
Page 17
Load Old Site Data – Permits the user to recall a complete setting, by name, hat was previously saved. Many of the settings for the DET-6B/12B will be the same for each city or jobsite. The most common change in the programming is the box number that will be transmitted.
Page 18
DET-6B/12B INSTALLATION AND OPERATION MANUAL 3. duAl line? _____________ LOC 7F2 Option for DET-6D only. 4. Index type: _____________LOC 7B8 OPEN or CLOSED (municipal is open) 5. busy Line: Waiting time for a busy line. _____________LOC 788 (20 = 2.0 minutes, standard). 0.1 to 9.9 minutes in tenths. 00 = the unit starts to transmit only when the line is free.
Page 19
2.2.2 Set Telegraph Codes When Set Telegraph Codes is selected, the screen display corresponds to the data provided in Section 2.1. DIGITIZE DET-6B/12B Program Data Locations, but not in the same order. All default values are already entered in the address locations.
Page 20
DET-6B/12B INSTALLATION AND OPERATION MANUAL 1. Box number for zone 1: ____________________ LOC 7C8 – 7CD (Up to five digits may be entered). 2. Box number for zone 2: ____________________ LOC 7CE – 7D3 (Up to five digits may be entered).
Page 21
DET-6B/12B INSTALLATION AND OPERATION MANUAL 10. If a zone goes into a trouble condition, what code do you wish to transmit? (7 is standard) For zone 1 ________________________ LOC 78F For zone 2 ________________________ LOC 790 For zone 3 ________________________...
Page 22
For zone 5 ________________________ (ROUNDS) LOC 7AE For zone 6 ________________________ (ROUNDS) LOC 7AF The DET-6B/12B is capable of transmitting a code when it detects that its battery voltage is below a preset level. The following locations have to do with transmission (or non- transmission) of a code when a low battery condition is detected.
DET-6B/12B and at the AC Terminal Input. Open the front of the DET-6B/12B and remove the two wires for the AC power input from the AC transformer. Remove the 4 screws that hold the sheet metal.
Page 24
A. Install a programmed EPROM into the socket in the upper left of the panel. The NOTCH on the IC chip should be facing DOWN. Apply 120 VAC power to the DET-6B/12B step down transformer. Then connect the 12 VDC battery for back up.
Page 25
DET-6B/12B INSTALLATION AND OPERATION MANUAL FIGURE 1 – WIRING DIAGRAM DET-6B DIGITIZE, INC. 700158-0000 REV.F 02/16...
Page 26
DET-6B/12B INSTALLATION AND OPERATION MANUAL FIGURE 2 – WIRING DIAGRAM DET-12B DIGITIZE, INC. 700158-0000 REV.F 02/16...
When the time has elapsed the microprocessor will activate relay K2 to send out the code for the alarm input. If the DET-6B/12B senses a code on the 100mA line, it will wait for the line to clear before trying to send its code.
If the voltages are correct and the DET-6B/12B is not working, the box guts should be replaced with a spare and the service left to qualified service personnel.
The battery should be checked at least once every six months to be sure that it has the ability to run the DET-6B/12B. To test the battery, remove the AC power from the unit and measure the 12 VDC going to the DET-6B/12B PCB. Should the voltage fall below 12 volts within the first 30 minutes, the battery should be replaced.
SECTION 6 DET-6B DUAL LINE The DET-6B dual line (P/N 425106-0000) is available. The DET-6B dual line (also called a DET-6D) has separate 100mA lines for Alarm and Trouble. For DET-6D operation, Zone 6 is shorted in order to activate the second milliamp circuit (Trouble).
Page 33
Digitize by telephone or in writing. Buyer will prepay all freight charges to return any products to the repair facility designated by Digitize and include the RMA number on the shipping container. Digitize will, at its option, either repair the defective products or parts or deliver replacements for defective products or parts on an exchange basis to Buyer, freight prepaid to the Buyer.