Error
Message
number
526
Ionizer Ion Level
527
Ionizer Condition
528
Pump Motor Sensor
549
LEnc. Count DIO
602
Ink End
608
Wrong Ink IC
64C
NCU Error
650
NCU CONNECT
651
Replace NCU
652
NCU Nzk Chk (Hw)
653
NCU Nzk Chk (Mark)
654
NCU Center Pos
655
NCU Flush Pos
656
NCU SN Adjst
657
Replace NCU Ink Pad
658
NCU Sensor Lv Low
65b
NCU Sens Adj Err H
65c
NCU Sens Adj Err L
715
InkHeater Thr
716
InkHeater Tmp
Cause
• The amount of generated
ions was reduced by
fouling and abrasion of the
electrode needle.
• Ambient conditions may
cause ions to be absorbed
by metals in the vicinity
and affect discharge
capability.
• A problem was detected
with the pump motor.
• A problem was detected
with the linear scale wiring
to the DIO PCB.
• The ink has run out.
• An error occurred with the
information on the ink IC
chip.
• The function is disabled
due to an error.
• A problem was detected
with the NCU connection.
• A problem was detected
with the nozzle clogging
assessment.
• A problem was detected
with the nozzle clogging
assessment.
• Printing position
adjustment failed.
• Sensor sensitivity
adjustment failed.
• The NCU ink absorber is
full.
• The sensor's sensitivity is
impaired.
• Sensor sensitivity
adjustment failed.
• A problem was detected
with the ink heater
thermistor.
131
Chapter 5 Troubleshooting
Corrective action
• Refer to the instruction manual for
the ionizer and clean the electrodes.
• Remove any conductors or
discharge devices close to the
ionizer.
• Turn off the power on the machine
and turn it on after a while.
• Turn off the power on the machine
and turn it on after a while.
• Replace with new ink.
"Replacing Ink"(P. 40)
1.
Check to confirm the ink IC chip was
inserted correctly.
"Registering the
Ink IC Chip"(P. 45)
2.
Turn off the power on the machine and
turn it on after a while.
3.
Replace with new ink.
Ink"(P. 40)
• Turn off the power on the machine
and turn it on after a while.
• The NCU must be replaced.
Contact your local distributor, our
sales office, or service center.
• Clean the NCU.
"NCU
Cleaning"(P. 97)
• The NCU ink absorber must be
replaced. Contact your local
distributor, our sales office, or
service center.
• Clean the NCU.
"NCU
Cleaning"(P. 97)
• Replace the NCU if the error does
not clear. Contact your local
distributor, our sales office, or
service center.
• Turn off the power on the machine
and turn it on after a while.
"Replacing
5
Need help?
Do you have a question about the UJV100-160 and is the answer not in the manual?
Questions and answers
как правильно и с какой периодичностью чистить отверстия на вакуумном столе? Как добраться и обслужить вентиляторы внутри стола принтера?
clean suction pump tube
how to clean the pump suction tube