Rated Power | 6W |
Effective Range | ≤ 161 ft² / 15 m² |
Operating Conditions | Temperature: 14°–104°F / -10°–40°C |
Humidity: ≤ 85% RH | |
Noise Level | 24–36dB |
Dimensions | 6.7 x 6.7 x 10.4 in / 17 x 17 x 26.5 cm |
Weight | 3.3 lb / 1.5 kg |
Power Adapter | Input: 100–240V~ 50/60Hz, 0.2A |
Output: 12V⎓ 600mA |
Note: The Indicator Ring lights up white when the air purifier is turned on, and lights up red to remind you to check your filters (see Check Filter Indicator Light).
Your Levoit Desktop True HEPA Air Purifier uses 2 filters, both of which use a 3-stage air filtration system to purify air.
Make sure the air outlet and the air inlets are not blocked. This may cause the air purifier to overheat and stop working.
Do not add essential oils to the filters or the fan. The filters will be damaged by the oil and will eventually release an unpleasant smell. Only add essential oils to the aroma box at the top of the air purifier.
Note: Essential oils are not included.
This air purifier has a Clean Air Delivery Rate of 70 cubic meters per hour.
Clean Air Delivery Rate (CADR) measures the efficiency of an air purifier by indicating the volume of clean air that an air purifier produces. This is based on the removal of dust, pollen, and smoke, which are the 3 most common indoor air pollutants. The higher the CADR, the more particles the air purifier will remove and the larger the area it can clean. The rating is measured at the air purifier's highest speed.
For highest efficiency of air purification, make sure that airflow isn't obstructed. To allow air to circulate freely in and out of the air purifier, there should ideally be 15 in / 38 cm of clearance on all sides of the air purifier. Avoid placing too near a corner or too close to a wall. Keep away from curtains and anything that might block airflow.
Moisture may damage the filters. This air purifier should be used in an area with a humidity level below 85% RH. If you use the air purifier in excessively humid areas, the surface of the filters will become moldy.
Note: Water or moisture will allow mold to grow. To solve a mold problem, get rid of the source of the moisture and clean up the mold. Air purifiers cannot solve an existing mold problem, only remove airborne mold spores and reduce odors.
Note:
The Pre-Filters should be cleaned about once a month to increase the efficiency and extend the life of your filters. Clean the outside of the Pre-Filter using a soft brush or a vacuum hose with a soft brush attachment to remove hair, dust, and large particles.
Do not clean any part of the filters with water or other liquids.
Filter | When to Clean | When to Replace |
Pre-Filters | Every 2–4 weeks | 6–8 months |
True HEPA & Activated Carbon Filters | Do not clean |
The Control Button will light up red as a reminder to check the filters. Depending on how often you use the air purifier, the indicator should turn on within 6–8 months. You may not need to replace your filters yet, but you should check them when the Control Button lights up red.
Reset the indicator light when:
For effective aromatherapy, the aroma pad should always be cleaned before using a new essential oil blend.
Do not mix essential oil blends.
To clean:
If the aroma pad becomes deformed or damaged after repeated washing, it may need to be replaced. Replacement aroma pads can be purchased at levoit.com/shop.
You should replace your filters every 6–8 months. You may need to change your filters sooner or later depending on how often you use your air purifier. Using your air purifier in an environment with relatively high pollution may mean you will need to change the filters more often, even if the red indicator light is off.
You may need to replace your filters if you notice:
Note: To maintain the performance of your air purifier, only use official Levoit filters. To buy replacement filters, visit
Levoit's online store. Go to levoit.com for more information.
If not using the air purifier for an extended period of time, wrap the filters in plastic packaging and store in a dry place to avoid moisture damage.
Problem | Possible Solution |
Air purifier will not turn on or respond to button controls. | Plug in the air purifier. |
Plug the air purifier into a different outlet. | |
Disconnect the AC power adapter from the air purifier and reconnect it. | |
Check to see if the AC power adapter is damaged. If so, stop using the air purifier and contact Customer Support. | |
The air purifier may be malfunctioning. Contact Customer Support. | |
Airflow is significantly reduced. | Make sure the filters are removed from their packaging and properly in place (see Getting Started). |
Press the Control Button to increase fan speed. | |
Leave at least 15 in / 38 cm of clearance on all sides of the air purifier. | |
The Pre-Filters may be clogged by large particles, such as hair or lint, blocking airflow. Clean the Pre-Filters (see Cleaning the Filters). | |
Replace the filters (see Replacing the Filters). | |
Air purifier makes an unusual noise while the fan is on. | Make sure the filters are properly in place with plastic packaging removed (see Getting Started). |
Make sure the air purifier is operating on a hard, flat, level surface. | |
Replace the filters (see Replacing the Filters). | |
The air purifier may be damaged, or a foreign object may be inside. Stop using the air purifier and contact Customer Support. Do not try to repair the air purifier. | |
Poor air purification quality. | Press the Control Button to increase fan speed. |
Make sure no objects are blocking the sides or top of the air purifier (the outlet or inlets). | |
Make sure the filters are removed from its packaging and properly in place (see Getting Started). | |
Close doors and windows while using the air purifier. | |
Make sure the room is smaller than 161 ft² / 15 m². The air purifier may not be as effective in larger rooms. | |
Replace the filters (see Replacing the Filters). | |
Strange smell coming from the air purifier. | Clean the filters and aroma pad or replace if necessary. |
Contact Customer Support. | |
Avoid using your air purifier in an area with high humidity. | |
The Check Filter Indicator light is still on after replacing the filters. | Reset the Check Filter Indicator (see Resetting the Check Filter Indicator Light). |
The Check Filter Indicator light has not turned on within 8 months. | The Check Filter Indicator light is a reminder for you to check the filters and will light up based on how long the air purifier has been used (see When Should I Replace the Filters?). If you don't use your air purifier often, the Check Filter Indicator light will take longer to turn on. |
The Check Filter Indicator light turned on before 6 months. | The Check Filter Indicator light is a reminder for you to check the filters and will light up based on how long the air purifier has been used (see When Should I Replace the Filters?). If you run your air purifier frequently, the Check Filter Indicator light will turn on sooner. |
If your problem is not listed, please contact Customer Support).
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Download Levoit LV-H128 Desktop True HEPA Air Purifier Manual
Advertisement
Need help?
Do you have a question about the LV-H128 and is the answer not in the manual?
Questions and answers