Summary of Contents for Alfa Laval T6

  • Page 1 Cooling Insulation for Gasketed Plate Heat Exchangers Instruction Manual Instruction Manual Lit. Code 200002797-1-EN-GB BRITISH ENGLISH...
  • Page 2 © Alfa Laval Corporate AB 2022-10 This document and its contents are subject to copyrights and other intellectual property rights owned by Alfa Laval Corporate AB. No part of this document may be copied, re-produced or transmitted in any form or by any means, or for any purpose, without Alfa Laval Corporate AB’s prior express written permission. Information and services provided in this document are made as a benefit and service to the user, and no representations or warranties are made about the accuracy or suitability of this information and these services for any purpose.
  • Page 3: Table Of Contents

    Contents 1 Introduction ........................5 2 Description ........................7 3 Limitations ........................9 4 Technical data ......................11 5 Dimensions .........................13 6 Measurement ......................15 7 Installation ........................21 Insulation for medium units..................21 7.1.1 Installation....................21 Insulation for large units..................24 7.2.1 Installation....................24...
  • Page 5: Introduction

    1 Introduction This document describes cooling insulation for gasketed plate heat exchangers. Cooling insulation design comes in two sizes: medium and large. In the table below, GPHE models are specified in order. Insulation size Product name (AQ-model) (AQ2T) Medium (AQ2L) (AQ2T) (AQ4L) TL10...
  • Page 6 1 Introduction 200002797-1-EN-GB...
  • Page 7: Description

    2 Description The insulation panels are designed to ensure simple assembly and disassembly. They are equipped with connecting latches for the medium and large sizes and screws for the small size. The insulation also includes a drip tray with a drainage to collect condensation from the heat exchanger.
  • Page 8 2 Description 200002797-1-EN-GB...
  • Page 9: Limitations

    3 Limitations The cooling insulation has the following limitations: • The insulation can only be used for a certain temperature range. For more information, see the section Technical data. • Insulation may not be available for all plate heat exchanger models with holed pressure plate.
  • Page 10 3 Limitations 200002797-1-EN-GB...
  • Page 11: Technical Data

    4 Technical data Insulation Drip tray Cladding material Aluminium stucco sheet Hot dip galvanized plate Insulation material Polyurethane Polyurethane Inside layer material Aluminium foil Hot dip galvanized plate Total insulation thickness 60 mm (2.36”) 60 mm (2.36”) Panel fixation Connecting latches -50 to 80 °C -50 to 80 °C Temperature range...
  • Page 12 4 Technical data 200002797-1-EN-GB...
  • Page 13: Dimensions

    5 Dimensions A = Plate pack length B = Foot print length LC = Length of the carrying bar H1 = Height of the insulation H2 = Height of the drip tray L1 = Length of the insulation L2 = Length of the drip tray W1 = Width of the insulation W2 = Width of the drip tray 200002797-1-EN-GB...
  • Page 14 5 Dimensions 200002797-1-EN-GB...
  • Page 15: Measurement

    The data listed in the table below are for a standard plate heat exchanger with a standard carrying bar, hole only in the frame plate and standard connections. For non-standard plate heat exchangers, contact your Alfa Laval representative. Insulation panels...
  • Page 16 6 Measurement Insulation panels Driptray Product Frame Type (AQ-mod- Unholed Unholed pressure pressure plate plate PED/ALS/ A+260 A+260 B+166 ASME PED/ALS A+320 A+350 B+166 (AQ2) ASME A+260 A+260 B+166 A + 330 LC + 200 A + 370 1114 FD/FG PED/ALS/ ASME (AQ4T)
  • Page 17 Measurement 6 Insulation panels Driptray Product Frame Type (AQ-mod- Unholed Unholed pressure pressure plate plate A + 490 LC + 367 A + 490 1929 ASME (A + 19.29) (31.41) (75.94) (32.67) (2.44) + 19.29) + 14.44) A + 470 LC + 357 A + 470 1914.5...
  • Page 18 6 Measurement Insulation panels Driptray Product Frame Type (AQ-mod- Unholed Unholed pressure pressure plate plate (2750 with stand- carry- PED/ALS/ bar) A+350 A+350 L1+300 ASME (2811 with rein- forced car- rying- bar) (2750 with stand- carry- TL15 PED/ALS/ bar) A+440 A+440 L1+300 ASME...
  • Page 19 Measurement 6 Insulation panels Driptray Product Frame Type (AQ-mod- Unholed Unholed pressure pressure plate plate (2225 with stand- carry- PED/ALS/ bar) A+480 A+480 A+750 ASME (2375 with rein- forced car- rying- bar) (AQ8) (2268 with stand- carry- bar) ASME A+530 A+530 A+560 (2418...
  • Page 20 6 Measurement Insulation panels Driptray Product Frame Type (AQ-mod- Unholed Unholed pressure pressure plate plate A + 560 LC + 490 A + 510 2248 PED/ALS/ ASME (A + 20.07) (37.00) (88.50) (37.79) (2.44) + 22.04) + 19.29) A + 510 LC + 490 A + 470 2210...
  • Page 21: Installation

    7 Installation 7.1 Insulation for medium units This section is only valid for insulation intended for medium units. See Chapter Introduction for sizing. On the rear insulation panel of medium sized insulations, cut out holes for tightening bolts and carrying bar. On the rear insulation panel of medium/large sized insulations, cut out holes for tightening bolts and carrying bar.
  • Page 22 7 Installation Assemble the front insulation panel parts starting from the bottom. Assemble the left hand side insulation panel. NOTE This step is only valid for insulation designs with rear insulation panel parts. Go to the next step if you do not have these parts for your gasketed plate heat exchanger.
  • Page 23 Installation 7 Assemble the rear insulation panel parts starting from the bottom. Assemble the right hand side insulation panel. 200002797-1-EN-GB...
  • Page 24: Insulation For Large Units

    7 Installation 7.2 Insulation for large units This section is only valid for insulation intended for large units. See Chapter Introduction for sizing. On the rear insulation panel of large sized insulations, cut out holes for tightening bolts and carrying bar. On the rear insulation panel of medium/large sized insulations, cut out holes for tightening bolts and carrying bar.
  • Page 25 Installation 7 Assemble the front insulation panel parts starting from the bottom. Assemble the left hand side insulation panel. NOTE This step is only valid for insulation designs with rear insulation panel parts. Go to the next step if you do not have these parts for your gasketed plate heat exchanger.
  • Page 26 7 Installation Assemble the rear insulation panel parts starting from the bottom. Assemble the right hand side insulation panel. Assemble the top insulation panel. 200002797-1-EN-GB...