WARNING — SHOCK HAZARD
Turn OFF the power to the branch circuit for the switch and lighting fixture at the service panel. All wiring connections must be made with the POWER OFF to avoid personal injury and/or damage to the switch. This device is intended for installation in accordance with the National Electric Code and local regulations in the United States, or the Canadian Electrical Code and local regulations in Canada. If you are unsure or uncomfortable about performing this installation, consult a qualified electrician.
MULTI-SWITCH WIRING
Add-on switch model 39350 is required for multi-switch installations. For more information on multi-switch installations, refer to the add-on switch manual.
SINGLE-SWITCH WIRING
OBSERVE IMPORTANT WIRING INFORMATION
This switch is rated for and intended to only be used with copper wire.
WIRE GAUGE REQUIREMENTS
Use 14AWG or larger wires suitable for at least 80°C for supplying line (hot), load, neutral, ground and traveler connections. UL specifies the tightening torque for the screws is 14Kgf-cm (12lbf-in)
WIRE STRIP LENGTH
Insert wires into holes, do not wrap wires around screws.
Do not remove screws.
MANUAL CONTROL
The front panel rocker switch allows the user to turn ON/OFF the connected fixture.
CYCLE LED LIGHT
The LED below the switch acts as a guide light or status indicator.
How to cycle through options: Press up three times and down once quickly.
CONNECTING TO A Z-WAVE NETWORK
If prompted by the controller to enter the S2 security code, refer to the QR code/security number on the back of the box or the QR code label on the product.
Quickly press ON (top) button three times, then, immediately press the OFF (bottom) button three times. The LED will flash ON/OFF five times when completed successfully.
NOTE: This should only be used in the event your network's primary controller is missing or otherwise inoperable.
NOTE: SmartStart enabled products can be added into a Z-Wave network by scanning the QR code on the product with a controller providing SmartStart inclusion. No further action is required and the SmartStart product will be added automatically within 10 minutes of being switched on in the network vicinity.
CHANGING THE COLOR OF THE PADDLE
NOTE: Additional colors available on www.byjasco.com.
This device supports Association Command Class (3 Groups)
Jasco Products Company warrants this product to be free from manufacturing defects for five years from the original date of consumer purchase. This warranty is limited to the repair or replacement of this product only and does not extend to consequential or incidental damage to other products that may be used with this product. This warranty is in lieu of all other warranties, expressed or implied. Some states do not allow limitations on how long an implied warranty lasts or permit the exclusion or limitation of incidental or consequential damage, so the above limitations may not apply to you. This warranty gives you specific rights and you may also have other rights which vary from state to state. Please contact our U.S.-based Consumer Care at 1-800-654-8483 (option 1) between 7AM – 8PM, M-F, Central Time or www.byjasco.com if the unit should prove defective within the warranty period.
ZW4008
Power: 120VAC, 60Hz
Signal (frequency): 908.4/916 MHz
Maximum loads: 960W incandescent, 1/2HP motor or 1800W (15A) resistive
Range: Up to 150ft. line of sight between the wireless controller and the closest Z-Wave receiver module Operating temperature range: 32-104°F (0-40°C)
Type 1 enclosure, independently mounted (vertical position only), operating control: type 1.c action, pollution degree (2), rated impulse voltage (2500V), software class A
For indoor use only
Specifications subject to change without notice due to continuing product improvement
This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.
This device complies with Part 15 of the FCC and Industry Canada license-exempt RSS standards. Operation is subject to the following two conditions:
FCC NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user's authority to operate the equipment
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy, and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
IMPORTANT NOTE: To comply with the FCC RF exposure compliance requirements, no change to the antenna or the device is permitted. Any change to the antenna or the device could result in the device exceeding the RF exposure requirements and void user's authority to operate the device.
Responsible Party - US Contact Information
FCC — U2ZZW4008 | IC: 6924A-ZW4008
Jasco Products Company | Model: ZW4008/39348
10 E. Memorial Rd., Oklahoma City, OK 73114 | 1-800-654-8483
CAN ICES-3(B)/NMB-3(B)
RISK OF FIRE
|
NOT FOR USE WITH MEDICAL
OR LIFE-SUPPORT EQUIPMENT
Z-WAVE ENABLED DEVICES
SHOULD NEVER BE USED TO
SUPPLY POWER TO OR
CONTROL THE ON/OFF STATUS OF MEDICAL AND
LIFE-SUPPORT EQUIPMENT.