Installation - Oriental motor 4IK25GN-AW2TJ Operating Manual

Table of Contents

Advertisement

Do not use the motor beyond its specifications, or electric shock,
injury or damage to equipment may result.
Do not touch the motor during operation or immediately after
stopping. The surface is hot and may cause a burn.
Do not hold the motor output shaft. This may cause injury.
Keep the area around the motor free of combustible materials in
order to prevent fire or a burn.
To prevent the risk of damage to equipment, leave nothing around
the motor that would obstruct ventilation.
To prevent bodily injury, do not touch the rotating parts (output
shaft, cooling fan) of the motor during operation.
When an abnormality is noted, turn off the power immediately, or
fire, electric shock or injury may occur.
The motor's surface temperature may exceed
70 °C, even under normal operating conditions. If a
motor is accessible during operation, post the
warning label shown in the figure in a conspicuous
position to prevent the risk of burns.
To dispose of the motor, disassemble it into parts and components
as much as possible and dispose of individual parts/components as
industrial waste.
Preparation
Checking the product
Upon opening the package, verify that the items listed below are included.
Report any missing or damaged items to the branch or sales office from
which you purchased the product.
Motor............................ 1 unit
Capacitor ...................... 1 piece (only for single-phase motors)
Capacitor cap ............... 1 piece (only for single-phase motors)
Operating manual......... 1 copy
Checking the model name
Check the model number against the number indicated on the product.
Induction motors
Model
4IK25GN-AW2TJ
4IK25GN-AW2T
4IK25GN-AW2TU
4IK25GN-AW2T
4IK25GN-CW2TJ
4IK25GN-CW2T
4IK25GN-CW2TE
4IK25GN-CW2T
5IK40GN-AW2TJ
5IK40GN-AW2T
5IK40GN-AW2TU
5IK40GN-AW2T
5IK40GN-CW2TJ
5IK40GN-CW2T
5IK40GN-CW2TE
5IK40GN-CW2T
5IK60GE-AW2TJ
5IK60GE-AW2T
5IK60GE-AW2TU
5IK60GE-AW2T
5IK60GE-CW2TJ
5IK60GE-CW2T
5IK60GE-CW2TE
5IK60GE-CW2T
5IK90GE-AW2TJ
5IK90GE-AW2T
5IK90GE-AW2TU
5IK90GE-AW2T
5IK90GE-CW2TJ
5IK90GE-CW2T
5IK90GE-CW2TE
5IK90GE-CW2T
4IK25GN-SW2T
4IK25GN-SW2T
5IK40GN-SW2T
5IK40GN-SW2T
5IK60GE-SW2T
5IK60GE-SW2T
5IK90GE-SW2T
5IK90GE-SW2T
5IK150A-TW2T
5IK150A-TW2T
Reversible motors
Model
4RK25GN-AW2TJ
4RK25GN-AW2T
4RK25GN-AW2TU
4RK25GN-AW2T
4RK25GN-CW2TJ
4RK25GN-CW2T
4RK25GN-CW2TE
4RK25GN-CW2T
5RK40GN-AW2TJ
5RK40GN-AW2T
5RK40GN-AW2TU
5RK40GN-AW2T
5RK40GN-CW2TJ
5RK40GN-CW2T
5RK40GN-CW2TE
5RK40GN-CW2T
5RK60GE-AW2TJ
5RK60GE-AW2T
5RK60GE-AW2TU
5RK60GE-AW2T
5RK60GE-CW2TJ
5RK60GE-CW2T
5RK60GE-CW2TE
5RK60GE-CW2T
2
Warning label
Motor model
Capacitor model
CH80CFAUL2
CH65CFAUL2
CH20BFAUL
CH15BFAUL
CH110CFAUL2
CH90CFAUL2
CH30BFAUL
CH23BFAUL
CH200CFAUL2
CH180CFAUL2
CH50BFAUL
CH40BFAUL
CH280CFAUL2
CH200CFAUL2
CH70BFAUL
CH60BFAUL
Motor model
Capacitor model
CH100CFAUL2
CH80CFAUL2
CH30BFAUL
CH25BFAUL
CH160CFAUL2
CH120CFAUL2
CH40BFAUL
CH35BFAUL
CH250CFAUL2
CH200CFAUL2
CH60BFAUL
CH50BFAUL
Model
5RK90GE-AW2TJ
5RK90GE-AW2T
5RK90GE-AW2TU
5RK90GE-AW2T
5RK90GE-CW2TJ
5RK90GE-CW2T
5RK90GE-CW3TE
5RK90GE-CW3T
The list above shows pinion shaft motors.
For the round shaft motor, "GN" and "GE" in the model and motor model
are replaced by "A." (5IK150A-TW2T is only available in the round shaft
specification.)

Installation

Location for installation
The motor is designed and manufactured for installation in equipment.
Install it in a well-ventilated location that provides easy access for inspection.
The location must also satisfy the following conditions:
Inside an enclosure that is installed indoors (provide vent holes)
Operating ambient temperature
−10 to +40 °C (+14 to +104 °F) (non-freezing)
−10 to +50 °C (+14 to +122 °F) for 100/200 V
Operating ambient humidity 85%, maximum (non-condensing)
Area that is free from an explosive atmosphere or toxic gas (such as
sulfuric gas) or liquid
Area not exposed to direct sun
Area free of excessive amount dust, iron particles or the like
Area not subject to splashing water (storms, water droplets), oil (oil
droplets) or other liquids
Area free of excessive salt
Area not subject to continuous vibration or excessive shocks
Area free of excessive electromagnetic noise (from welders, power
machinery, etc.)
Area free of radioactive materials, magnetic fields or vacuum
1000 m or less above sea level
How to install the motor
Round shaft type
Drill holes on the mounting plate
and fix the motor on the plate
using screws, nuts, and washers
(not supplied). Be careful there is
no gap between the motor
installation surface and the
bracket.
First number of
Nominal diameter of
motor model
4
5
Note
Do not insert the motor into the mounting hole at an angle or force
it in, as this may scratch the flange pilot section and damage the
motor.
Pinion shaft type
Drill holes on the mounting plate and fix the motor and gearhead on the plate
using screws supplied with the gearhead. Be careful there is no gap between
the motor flange and the gearhead.
For details of installation, see the operating manual provided with the
gearhead, which is sold separately.
Motor
Washers
Nuts
Gearhead
Mounting plate
Note
Use the gearhead with pinion shaft which is identical with one of
motor.
Motor with cooling fan
When installing a motor with cooling fan onto a device, leave 10 mm
(0.39 in.) or more behind the fan cover or open a ventilation hole so that the
cooling inlet on the back of the motor cover is not blocked.
Motor model
Capacitor model
CH350CFAUL2
CH300CFAUL2
CH80BFAUL
CH70BFAUL
Motor
Washers
Nuts
Mounting plate
Tightening torque
screw
[N·m (lb-in)]
M5
2.5 (22)
M6
3.0 (26)
Screws provided
with gearhead
Mounting
screws

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 4IK25GN-AW2TJ and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

4ik25gn-aw2t4ik25gn-aw2tu4ik25gn-cw2tj4ik25gn-cw2t4ik25gn-cw2te5ik40gn-aw2tj ... Show all

Table of Contents