CODE
DESCRIPTION/CAUSE
182
With the low currency
feature enabled, this error
condition will occur before
the cassette is actually
empty. There should be
about 1/4 inch of currency
(approximately 60 bills) in
the cassette when the error is
detected.
Currency cassette low (SDD
dispensers only)
185
Host telephone number not
entered.
Phone number not
confi gured
186
Cassette denominations not
confi gured.
Bill size not confi gured
correctly
187
The maximum withdrawal
amount cannot exceed 50
notes.
Maximum withdrawal not
confi gured correctly
188
PIN working keys not
downloaded from host.
Communications key not
confi gured
189
Terminal ID not confi gured
190
This error code is often
caused by a SPED tamper.
If you suspect SPED tamper
or Error code 205, see the
corrective action for EC 205.
Master key not confi gured
192
Communication parameters
not entered or incorrect.
Modem error. Phone or
Ethernet cable fault. A
problem exists at the host.
CD communications error
195
No paper.
Receipt printer out of paper
ARGO S
M
ERVICE
ANUAL
ACTION
1) Reset/restart the ATM.
2) Remove the cassette from the
dispensing mechanism.
3) Press the reset error key.
4) Refi ll and install the cassette.
1) Enter the host phone number.
1) Confi gure the fast cash and multiple
amount (note value).
1) Confi gure multiple amount.
1) Master keys must be loaded. Download
working keys from host.
1) Confi gure terminal ID.
1) Enter master keys.
1) Enter Management Functions >
Communication menus and verify that all
terminal parameters have been entered
correctly.
2) Verify that the telephone or TCP/IP line
is operational.
3) Reset or restart the terminal. Attempt to
clear the error.
4) If the error persists, possible causes
may be the modem or mainboard assembly.
1) Replenish the paper. Clear the error.
15
REFERENCE
General Access
General Troubleshooting:
Cash Dispenser Errors
Major Components: Cash
Dispenser Unit
See XScale/X2 Confi guration
Manual
Or
Basic Setup of the Triton
ATMs
Major Components:
Customer Keypad
See XScale/X2 Confi guration
Manual
General Access
Communication Issues:
- Basic Dialup
Communication Checks
- Basic TCP/IP
Communication Checks
General Access
General Troubleshooting:
Printer Errors
Major Components: Receipt
Printer

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ATMGurus ARGO Series and is the answer not in the manual?

Questions and answers

Table of Contents