SINAMICS G130
Voltage Sensing Module 10 (VSM10)
Operating instructions · 03/2012
SINAMICS
s

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SINAMICS G130

  • Page 1 SINAMICS G130 Voltage Sensing Module 10 (VSM10) Operating instructions · 03/2012 SINAMICS...
  • Page 3 ___________________ Voltage Sensing Module 10 (VSM10) Safety information ___________________ General ___________________ Mechanical installation SINAMICS ___________________ Electrical installation SINAMICS G130 ___________________ Voltage Sensing Module 10 Technical specifications (VSM10) Operating Instructions Control version V4.5 03/2012 A5E02142235A...
  • Page 4 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 5: Table Of Contents

    Table of contents Safety information............................5 Warnings ............................5 Safety and application instructions ....................6 Components that can be destroyed by electrostatic discharge (ESD) ..........7 General..............................9 Safety information ..........................9 Mechanical installation..........................11 Electrical installation ..........................13 Overview ............................13 Connection diagram........................14 Interface description........................15 4.3.1 Electronics power supply X524....................15 4.3.2...
  • Page 6 Table of contents Voltage Sensing Module 10 (VSM10) Operating Instructions, 03/2012, A5E02142235A...
  • Page 7: Safety Information

    Safety information Warnings WARNING Hazardous voltages are present when electrical equipment is in operation. Severe personal injury or substantial material damage may result if these warnings are not observed. Only qualified personnel are permitted to work on or around the equipment. This personnel must be thoroughly familiar with all the warnings and maintenance procedures described in these operating instructions.
  • Page 8: Safety And Application Instructions

    The operating manual and machine documentation are written in different languages as specified in the delivery contracts. Note We recommend engaging the support and services of your local Siemens service center for all planning, installation, commissioning and maintenance work. Voltage Sensing Module 10 (VSM10)
  • Page 9: Components That Can Be Destroyed By Electrostatic Discharge (Esd)

    Safety information 1.3 Components that can be destroyed by electrostatic discharge (ESD) Components that can be destroyed by electrostatic discharge (ESD) CAUTION The board contains components that can be destroyed by electrostatic discharge. These components can be easily destroyed if not handled properly. If you do have to use electronic boards, however, please observe the following: •...
  • Page 10 Safety information 1.3 Components that can be destroyed by electrostatic discharge (ESD) Voltage Sensing Module 10 (VSM10) Operating Instructions, 03/2012, A5E02142235A...
  • Page 11: General

    General The Voltage Sensing Module VSM10 is used to operate a permanent-magnet synchronous machine without encoder with the requirement for switching to a machine which is already running (flying restart function). To commission the function, the permanent-field synchronous machine without encoder must be input and "Flying restart"...
  • Page 12 General 2.1 Safety information Voltage Sensing Module 10 (VSM10) Operating Instructions, 03/2012, A5E02142235A...
  • Page 13: Mechanical Installation

    Mechanical installation Figure 3-1 Dimension drawing of Voltage Sensing Module VSM10 Note The VSM10 is installed near the Power Module on a mounting rail which must be provided by the customer. Voltage Sensing Module 10 (VSM10) Operating Instructions, 03/2012, A5E02142235A...
  • Page 14 Mechanical installation Voltage Sensing Module 10 (VSM10) Operating Instructions, 03/2012, A5E02142235A...
  • Page 15: Electrical Installation

    Electrical installation Overview Figure 4-1 Voltage Sensing Module VSM10 Voltage Sensing Module 10 (VSM10) Operating Instructions, 03/2012, A5E02142235A...
  • Page 16: Connection Diagram

    Electrical installation 4.2 Connection diagram Connection diagram Figure 4-2 Connection example VSM10 for operation of a permanent-magnet synchronous machine without encoder CAUTION The voltages for the cable to terminal -X522 must be taken downstream of an optional reactor or dv/dt filter, where possible directly at the motor connection terminals. Voltage Sensing Module 10 (VSM10) Operating Instructions, 03/2012, A5E02142235A...
  • Page 17: Interface Description

    Electrical installation 4.3 Interface description CAUTION The cable for the -X522 connection must be routed to prevent short-circuiting and ground faults in accordance with IEC 61800-5-2:2007, Table D.1. This can be accomplished, for example, by: • Eliminating the risk of mechanical damage to the cables •...
  • Page 18: Drive-Cliq Interface X500

    Electrical installation 4.3 Interface description 4.3.2 DRIVE-CLiQ interface X500 Table 4- 2 DRIVE-CLiQ interface X500 Signal name Technical specifications Transmit data + Transmit data - Receive data + Reserved, do not use Reserved, do not use Receive data - Reserved, do not use Reserved, do not use + (24 V) Power supply...
  • Page 19: X521 Three-Phase Line Supply Voltage Sensing Up To 100 V (Phase-To-Phase)

    Electrical installation 4.3 Interface description Note In order to minimize noise emission, shielded cables should be used. Note The maximum cable length for a shielded cable – connected at both ends – to the temperature sensor and to the analog inputs is 30 m. 4.3.4 X521 three-phase line supply voltage sensing up to 100 V (phase-to-phase) Table 4- 4...
  • Page 20: X522 Three-Phase Line Supply Voltage Sensing Up To 690 V (Phase-To-Phase)

    Electrical installation 4.3 Interface description 4.3.5 X522 three-phase line supply voltage sensing up to 690 V (phase-to-phase) Table 4- 5 Terminal block X522 Terminal Designation Technical specifications Phase voltage U Directly connected to sense the line supply voltage Phase voltage V Phase voltage W Max.
  • Page 21: Technical Specifications

    Technical specifications General technical data Table 5- 1 General technical data Product standard EN 61800-5-1 Technical data Table 5- 2 Technical data Unit Value Electronic power supply Voltage 24 DC (20.4 – 28.8) Current (without DRIVE-CLiQ or digital outputs) Power loss <10 PE/ground connection On the housing with M4, 1.8 Nm screw...
  • Page 22 Technical specifications Voltage Sensing Module 10 (VSM10) Operating Instructions, 03/2012, A5E02142235A...
  • Page 24 Siemens AG Subject to change without prior notice Industry Sector © Siemens AG 2012 Drive Technologies Large Drives P.O. Box 4743 90025 NUREMBERG GERMANY www.siemens.com/automation...