Download Print this page

Sealey SA4025/3.V3 Instructions

Quiet running compressor

Advertisement

Quick Links

thank you for purchasing a sealey product. manufactured to a high standard this product will, if used according to these instructions
and properly maintained, give you years of trouble free performance.
IMPORTANT: pLeAse reAD tHese instructions cAreFuLLY. note tHe sAFe operAtionAL requirements, WArnings AnD cAutions.
use tHe proDuct correctLY AnD WitH cAre For tHe purpose For WHicH it is intenDeD. FAiLure to Do so mAY cAuse
DAmAge AnD/or personAL inJurY AnD WiLL invALiDAte tHe WArrAntY. pLeAse Keep instructions sAFe For Future use.
1. sAFetY instructions
1.1.
eLectricAL sAFetY.
You must check all electrical equipment and appliances to ensure they are safe before using. You must inspect power supply leads, plugs and
all electrical connections for wear or damage. You must ensure the risk of electric shock is minimised by the installation of appropriate safety
devices. An rccB (residual current circuit Breaker) should be incorporated in the main distribution board. We also recommend that an rcD
(residual current Device) is used with all electrical products. it is particularly important to use an rcD with portable products that are plugged
into an electrical supply not protected by an rccB. if in doubt consult a qualified electrician. You may obtain a residual current Device by
contacting your sealey dealer. You must also read and understand the following instructions concerning electrical safety.
1.1.1. the Electricity At Work Act 1989 requires all portable electrical appliances, if used on business premises, to be tested by
a qualified electrician, using a Portable Appliance tester (PAt), at least once a year.
1.1.2. the Health & Safety at Work Act 1974 makes owners of electrical appliances responsible for the safe condition of those appliances
and the safety of appliance operators. If in any doubt about electrical safety, contact a qualified electrician.
1.1.3. Ensure the insulation on all cables and the product itself is safe before connecting to the mains power supply.
see 1.1.1. & 1.1.2. above and use a Portable Appliance tester (PAt).
1.1.4. Ensure that cables are always protected against short circuit and overload.
1.1.5. regularly inspect power supply leads and plugs for wear or damage and connections to ensure that none is loose.
1.1.6. Important: Ensure the voltage marked on the product is the same as the electrical power supply to be used, and check that plugs are
fitted with the correct capacity fuse.
1.1.7. Do not pull or carry the powered appliance by its power supply lead.
1.1.8. Do not pull power plugs from sockets by the power cable.
1.1.9. Do not use worn or damage leads, plugs or connections. immediately replace or have repaired by a
qualified electrician.
1.1.10. A u.K. 3 pin plug with AstA/Bs approval is fitted. in case of damage, cut off and fit a new plug
according
to the following instructions (uK only - see diagram at right). Discard old plug safely.
Ensure the unit is correctly earthed via a three-pin plug.
a) connect the green/yellow earth wire to the earth terminal 'e'.
b) connect the brown live wire to the live terminal 'L'.
c) connect the blue neutral wire to the neutral terminal 'n'.
d) ensure the plug is fitted with a 13 amp fuse.
e) After wiring, check that there are no bare wires, that all wires have been correctly connected, that the cable outer
insulation extends past the cable restraint and that the cable restraint is tight.
note: If uSEd ON A dOMESTIc 13 AMP SuPPlY ANd THE fuSE REPEATEdlY blOWS, cONTAcT A quAlIfIEd
ElEcTRIcIAN TO INSTAll A 30 AMP SuPPlY.
1.2.
generAL sAFetY instructions
familiarise yourself with the application and limitations of the compressor.
Ensure the compressor is in good order and condition before use. if in any doubt do not use the unit and contact an electrician/service agent.
WArning! compressor must only be serviced by an authorised agent. Do not tamper with, or attempt to adjust, pressure switch
or safety valve.
Before moving, or maintaining the compressor ensure it is unplugged from the mains supply and that the air tank pressure has been vented.
only use recommended attachments and parts. using non-recommended parts may be dangerous and will invalidate your warranty.
Before use, read the instructions relating to any accessory used with the compressor. Ensure the safe working pressure of any air appliance
used exceeds the compressor output pressure. if using a spray gun, check that the area selected for spraying is provided with an air change
system, or other suitable ventilation.
Ensure the air supply valve is turned off before disconnecting the air supply hose.
use the compressor in a well ventilated area and ensure it is placed on a firm surface.
Keep tools and other items away from the compressor when it is in use and keep area clean and clear of unnecessary items.
Ensure the air hose is not tangled, twisted or pinched.
Keep children and unauthorised persons away from the working area.
Do not dis-assemble compressor for any reason. the unit must be checked by qualified personnel only.
only operate the compressor with the outer cover intact and closed. Do not open the compressor covers whilst in operation.
Do not use the compressor outdoors, or in damp, or wet, locations and Do not operate in the vicinity of flammable liquids, gases or solids.
Do not touch compressor cylinder, cylinder head or pipe from head to tank as these may be hot and will remain so for some time after
shutdown.
Do not use the compressor to perform a task for which it is not designed.
Do not deface the certification plate attached to the end of the compressor tank.
Do not cover the compressor or restrict air flow around the machine whilst operating.
dANGER! dO NOT direct the compressed air jet towards people or animals.
Do not operate the compressor without an inlet air filter.
Do not allow anyone to operate the compressor unless they have received full instructions.
WArning! It is the user's responsibility to read, understand and comply with the following:
Original Language Version
instructions for:
quiet running compressor
3.0hp, 230v
sA4025/3.v3
moDEL no:
Yellow & Green
Earth wire
brown
live
blue
wire
Neutral
wire
cable
restraint
sA4025/3.V3
issue: 2 - 21/10/09

Advertisement

loading

Summary of Contents for Sealey SA4025/3.V3

  • Page 1 IMPORTANT: pLeAse reAD tHese instructions cAreFuLLY. note tHe sAFe operAtionAL requirements, WArnings AnD cAutions.
  • Page 2 (rpm) (cfm) (ltr) (psi/bar) (dB.A) max. (hp/kW) 2.5 Bar* 6.0 Bar* sA4025/3.v3 3/2.2 230/1 1000 14.9 12.0 11.1 145/10 All performance figures are ± 5% * note: 2.5 bar is recommended pressure setting for spraying. 2.2. Weights & Dimensions 6.0 bar is recommended pressure setting for air tools.
  • Page 3 3-monthly. operation to be carried out a) check tank for internal corrosion. 5.5. every 500 hours. operations to be carried out : a) change air filter element. b) check the automatic cut-out at max. pressure and the automatic cut-in at 2 bar below. Original Language Version sA4025/3.V3 issue: 2 - 21/10/09...
  • Page 4 5.8.2 temperatures ranging from +5°c to +25°c. • check tank for internal corrosion • 5.8.3 sEALEY cPo, or equivalent, sAE 40 compressor oil. replace air filter • check auto. cut-out 5.8.4 room temperature below +5°c: sAE 20 compressor switch settings oil.