Panasonic AQ-G Manual
Panasonic AQ-G Manual

Panasonic AQ-G Manual

Solid state relays

Advertisement

Quick Links

Solid State Relays
AQ-G
RELAYS
Slim type SSR for 1 A and 2 A control
ORDERING INFORMATION (PART NO.)
TYPES
Method
Zero-cross
Random
2019.07
industrial.panasonic.com/ac/e/
AQG
AQG
2 2
Load current
Load voltage
1: 1 A
2: 75 to 264 Vrms
2: 2 A
Load current
Load voltage
1 A
75 to 264 Vrms
2 A
75 to 264 Vrms
1 A
75 to 264 Vrms
2 A
75 to 264 Vrms
Automation Controls Catalog
FEATURES
Vertical size with a maximum thickness of 4.5 mm
Built-in snubber circuit prevents malfunction due to
noise.
Zero-cross method and Random method available
High dielectric strength: 3,000 Vrms (between input
and output)
Safety standards
• C-UL (UL508) certified
• VDE (EN60950-1) reinforced insulation certified
TYPICAL APPLICATIONS
Household appliances such as air conditioners and
dehumidifiers
Healthcare and medical equipment
Industrial machinery such as NC machines,
mounters, injection molders, and robots
Microcomputer boards
Amusement and amenity related equipment
Type
Control voltage
1: Zero-cross (3,000 V)
05: 4 to 6 V DC
2: Random (3,000 V)
12: 9.6 to 14.4 V DC
24: 19.2 to 28.8 V DC
Control voltage
4 to 6 V DC
9.6 to 14.4 V DC
19.2 to 28.8 V DC
4 to 6 V DC
9.6 to 14.4 V DC
19.2 to 28.8 V DC
4 to 6 V DC
9.6 to 14.4 V DC
19.2 to 28.8 V DC
4 to 6 V DC
9.6 to 14.4 V DC
19.2 to 28.8 V DC
ー 1 ー
c
Panasonic Corporation 2019
Part No.
Standard Packing
AQG12105
AQG12112
AQG12124
AQG22105
AQG22112
AQG22124
Carton: 20 pcs.
Case: 500 pcs.
AQG12205
AQG12212
AQG12224
AQG22205
AQG22212
AQG22224
ASCTB23E 201907

Advertisement

Table of Contents
loading

Summary of Contents for Panasonic AQ-G

  • Page 1 AQG12212 19.2 to 28.8 V DC AQG12224 Random 4 to 6 V DC AQG22205 75 to 264 Vrms 9.6 to 14.4 V DC AQG22212 19.2 to 28.8 V DC AQG22224 2019.07 industrial.panasonic.com/ac/e/ ASCTB23E 201907 ー 1 ー Panasonic Corporation 2019...
  • Page 2 Solid State Relays AQ-G RELAYS RATING Ratings (Ambient temperature: 20°C, Input voltage ripple: 1% or less) Zero-cross Part No. AQG12105 AQG12112 AQG12124 AQG22105 AQG22112 AQG22124 Remarks Item Rated voltage 5 V DC 12 V DC 24 V DC 5 V DC...
  • Page 3 Solid State Relays AQ-G RELAYS REFERENCE DATA 1. Load current vs. ambient temperature 2-1. Non-repetitive surge current vs. 2-2. Non-repetitive surge current vs. carrying characteristics carrying time* (1A Type) time* (2A Type) Ambient temperature: 20°C Ambient temperature: 20°C 2 A type...
  • Page 4 Solid State Relays AQ-G RELAYS SCHEMATIC AND WIRING DIAGRAMS Output Schematic Load Wiring diagram configuration Input circuit INPUT LOAD − Zero-cross circuit 1 Form A Load Operation Load power power supply Input circuit − Recommended Temperature Controllers Space saving requiring only a depth of 56 mm KT4H Temperature Controller •...
  • Page 5: Safety Warnings

    Derating is a significant factor for reliable design and product life. Type Load current Even if the conditions of use (temperature, current, voltage, etc.) AQ-G All models 20 mA of the product are within the absolute maximum ratings, AQ1 All models...
  • Page 6 50 mA. Load Load 2) Voltage-sensitive type (AQ-G, AQ1, AQ8, AQ-J, AQ-A) (1) The Emin. should exceed the minimum rated control voltage (2) The Emax. should not exceed the maximum rated control 3) Clamp diode and snubber circuit can limit spike voltages at voltage the load side.
  • Page 7: Transportation And Storage

    248°F Condensation causes the failures such as insulation = Max. 260°C 500°F deterioration. Panasonic Corporation does not guarantee the = within 60 s = within 5 s failures caused by water condensation. The heat conduction by the equipment the SSR is mounted may accelerate the water condensation.
  • Page 8 Cautions for Use of Solid State Relays 18. The following shows the packaging format 1) Tape and reel (Phototriac coupler) Type Tape dimensions (Unit: mm inch) Dimensions of paper tape reel (Unit: mm inch) ±0.8 ±.031 .827 ±1 dia. Direction of picking ±.039 3.150 dia.
  • Page 9: Snubber Circuit

    Cautions for Use of Solid State Relays 2) Tape and reel (AQ-H) Type Tape dimensions (Unit: mm inch) Dimensions of paper tape reel (Unit: mm inch) ±0.8 ±.031 .827 Direction of picking ±1 dia. Tractor feed holes ±0.1 1.75 ±0.1 ±0.1 ±.039 +0.1...
  • Page 10: Protection Circuit

    7.5±1 (1) × (2) × (3) × (4) = (100 × M2) × 1.1 × 1.1 × 1.1 = 188 (V) .298±.039 (Unit: mm inch) Example of ZNR (Panasonic) Withstanding energy Withstanding surge current Electrostatic Max. average Max. allowable circuit Max.
  • Page 11 Cautions for Use of Solid State Relays 2. Over-Current Protection An SSR circuit operated without overcurrent protection may Example of executing fuse selection of over-current protection result in damage to the device. Design the circuit so the device’s cooperation rated junction temperature is not exceeded for a continuous 1,000 overload current.
  • Page 12: Relay Driver

    Cautions for Use of Solid State Relays Load Inrush Current Wave and Time (1) Incandescent Lamp Load (2) Mercury Lamp Load (3) Fluorescent Lamp Load ]3 times ]5 to 10 times Contacts (for high power factor type) Incandescent lamp 3 to 10 seconds 5 minutes or less...
  • Page 13 Cautions for Use of Solid State Relays 6. Self Sustaining Circuit Using SSR 7. Driving with a Shared Supply Load Load Load power supply Load power supply Terminal A: ON input pulse Terminal B: OFF input pulse Phototriac Coupler, AQ-H Solid State Relay Driving Circuits *Phototriac coupler and AQ-H is current driving type 1.
  • Page 14 Please contact ..Electromechanical Control Business Division 1006, Oaza Kadoma, Kadoma-shi, Osaka 571-8506, Japan industral.panasonic.com/ac/e/ ©Panasonic Corporation 2019 ASCTB23E 201907 Specifications are subject to change without notice.

This manual is also suitable for:

Aqg22212

Table of Contents