Page 1
AQG12212 19.2 to 28.8 V DC AQG12224 Random 4 to 6 V DC AQG22205 75 to 264 Vrms 9.6 to 14.4 V DC AQG22212 19.2 to 28.8 V DC AQG22224 2019.07 industrial.panasonic.com/ac/e/ ASCTB23E 201907 ー 1 ー Panasonic Corporation 2019...
Page 2
Solid State Relays AQ-G RELAYS RATING Ratings (Ambient temperature: 20°C, Input voltage ripple: 1% or less) Zero-cross Part No. AQG12105 AQG12112 AQG12124 AQG22105 AQG22112 AQG22124 Remarks Item Rated voltage 5 V DC 12 V DC 24 V DC 5 V DC...
Page 3
Solid State Relays AQ-G RELAYS REFERENCE DATA 1. Load current vs. ambient temperature 2-1. Non-repetitive surge current vs. 2-2. Non-repetitive surge current vs. carrying characteristics carrying time* (1A Type) time* (2A Type) Ambient temperature: 20°C Ambient temperature: 20°C 2 A type...
Page 4
Solid State Relays AQ-G RELAYS SCHEMATIC AND WIRING DIAGRAMS Output Schematic Load Wiring diagram configuration Input circuit INPUT LOAD − Zero-cross circuit 1 Form A Load Operation Load power power supply Input circuit − Recommended Temperature Controllers Space saving requiring only a depth of 56 mm KT4H Temperature Controller •...
Derating is a significant factor for reliable design and product life. Type Load current Even if the conditions of use (temperature, current, voltage, etc.) AQ-G All models 20 mA of the product are within the absolute maximum ratings, AQ1 All models...
Page 6
50 mA. Load Load 2) Voltage-sensitive type (AQ-G, AQ1, AQ8, AQ-J, AQ-A) (1) The Emin. should exceed the minimum rated control voltage (2) The Emax. should not exceed the maximum rated control 3) Clamp diode and snubber circuit can limit spike voltages at voltage the load side.
248°F Condensation causes the failures such as insulation = Max. 260°C 500°F deterioration. Panasonic Corporation does not guarantee the = within 60 s = within 5 s failures caused by water condensation. The heat conduction by the equipment the SSR is mounted may accelerate the water condensation.
Page 8
Cautions for Use of Solid State Relays 18. The following shows the packaging format 1) Tape and reel (Phototriac coupler) Type Tape dimensions (Unit: mm inch) Dimensions of paper tape reel (Unit: mm inch) ±0.8 ±.031 .827 ±1 dia. Direction of picking ±.039 3.150 dia.
Cautions for Use of Solid State Relays 2) Tape and reel (AQ-H) Type Tape dimensions (Unit: mm inch) Dimensions of paper tape reel (Unit: mm inch) ±0.8 ±.031 .827 Direction of picking ±1 dia. Tractor feed holes ±0.1 1.75 ±0.1 ±0.1 ±.039 +0.1...
7.5±1 (1) × (2) × (3) × (4) = (100 × M2) × 1.1 × 1.1 × 1.1 = 188 (V) .298±.039 (Unit: mm inch) Example of ZNR (Panasonic) Withstanding energy Withstanding surge current Electrostatic Max. average Max. allowable circuit Max.
Page 11
Cautions for Use of Solid State Relays 2. Over-Current Protection An SSR circuit operated without overcurrent protection may Example of executing fuse selection of over-current protection result in damage to the device. Design the circuit so the device’s cooperation rated junction temperature is not exceeded for a continuous 1,000 overload current.
Cautions for Use of Solid State Relays Load Inrush Current Wave and Time (1) Incandescent Lamp Load (2) Mercury Lamp Load (3) Fluorescent Lamp Load ]3 times ]5 to 10 times Contacts (for high power factor type) Incandescent lamp 3 to 10 seconds 5 minutes or less...
Page 13
Cautions for Use of Solid State Relays 6. Self Sustaining Circuit Using SSR 7. Driving with a Shared Supply Load Load Load power supply Load power supply Terminal A: ON input pulse Terminal B: OFF input pulse Phototriac Coupler, AQ-H Solid State Relay Driving Circuits *Phototriac coupler and AQ-H is current driving type 1.