Page 1
ENGLISH ® Ewon Cosy+ INSTALLATION GUIDE IG-0031-00 1.2 Publication date 16/01/2023...
Page 2
The information in this document shall therefore not be construed as a commitment on the part of HMS Networks and is subject to change without notice. HMS Networks makes no commitment to update or keep current the information in this document.
® Ewon Cosy+ Table of Contents 1. Preface ..........................1 1.1. About This Document ......................1 1.2. Document History ......................1 1.3. Related Documents ......................1 1.4. Trademark Information ...................... 1 2. Product Summary ........................2 2.1. Type & Part Numbers ......................2 2.2.
Page 4
® Ewon Cosy+ 6.3. Connecting to the LAN IP Address ..................25 ® 6.4. Ewon Cosy+ Web Interface ....................25 7. Troubleshooting ........................27 7.1. Standard Boot Process ...................... 27 ® 7.2. Reset of the Ewon Cosy+ ....................27 7.2.1. First Reset Level: User Reset ..................27 7.2.2.
® General Reference Guide for Ewon Cosy+ RG-0011-00 1.4. Trademark Information Ewon® is a registered trademark of HMS Networks SA. All other trademarks mentioned in this document are the property of their respective holders. IG-0031-00 1.2 Page 1 of 32...
® Product Summary Ewon Cosy+ 2. Product Summary 2.1. Type & Part Numbers ® There are 5 models of the Ewon Cosy+ each proposing different communication media. They include the following part numbers: Part number Model Model name Description ® EC71330_00MA 01702 Ewon...
® Safety, Environmental & Regulatory Information Ewon Cosy+ 3. Safety, Environmental & Regulatory Information 3.1. Scope ® This chapter addresses safety, environmental and regulatory information for the Ewon Cosy+. 3.2. Power Supply The external power supply is a third-party device that is not part of this certification. The equipment should be supplied from external, separately provided power supply 12-24Vdc, 30W min., certified for 60°C and for altitudes up to 2000m.
® Field Implementation & Environmental Conditions Ewon Cosy+ ® Figure 1. Mechanical dimensions of the Ewon Cosy+ 3.4.4. Mounting Recommendations The product is intended to be mounted vertically with the main connector on the top. ® The normal mounting position of the Ewon Cosy+ is to be mounted on a horizontal Omega type DIN rail.
Page 9
® Field Implementation & Environmental Conditions Ewon Cosy+ Figure 2. DIN Rail Mounting Position Description SIM card slot DIN rail mounting bracket • Mounting the unit on a wall ® If there is no DIN rail available for the mounting, you can also fix your Ewon Cosy+ directly on the wall.
® Field Implementation & Environmental Conditions Ewon Cosy+ Figure 3. Wall Mounting Position Description SIM card slot • Wall Mounting Bracket (suggested screw dimensions 4,2 x 32 mm) • DIN Rail Clip with a hole for a second screw CAUTION Set the screws in both wall mounting brackets to prevent accidents.
® Field Implementation & Environmental Conditions Ewon Cosy+ ® Figure 4. Free gap surrounding the Ewon Cosy+ for heat dissipation. 3.4.6. Cabling Rules ® Shielded cables must be used for Ethernet and USB connectivity of the Ewon Cosy+ to comply with the EMC requirements.
® Internal Battery Ewon Cosy+ Table 1. Environmental conditions Operating temperature -25°C to +60°C Operating relative humidity 10 to 95% non-condensing Operating altitude Up to maximum 2000m Storage temperature -30°C to +70°C Storage altitude Up to maximum 3000m Storage humidity 10 to 95% non-condensing IMPORTANT If the mounting situation mentioned is not applied, the specified operating temperature has to be...
® Hardware Description Ewon Cosy+ 4. Hardware Description 4.1. Label ® The identification label of the Ewon Cosy+ is placed on the right hand side of the housing. The different parts of the label are described as follows: ® Figure 5. Ewon Cosy+ Label Example ®...
Page 14
® Label Ewon Cosy+ Marks Description Conformité Européenne or European Conformity (EC) UL Listed — Underwriters Laboratories FCC — Federal Communications Commission UKCA – UK Conformity Assessed JAPAN MIC – GITEKI CERTIFICATION The following tables explain the Part Number syntax: Table 3.
® Overall Description Ewon Cosy+ 4.2. Overall Description 4.2.1. Front Panel ® Figure 6. Front panel of the Ewon Cosy+ Table 4. Description of the front panel Description Reset button Status LEDs LAN/WAN Ethernet ports and corresponding status LEDs: • Orange: WAN port •...
® Overall Description Ewon Cosy+ 4.2.2. Upper Side ® Figure 7. Main connector and plug of the Ewon Cosy+ For more information about the connector, refer to Main Connector (page 30) section. 4.2.3. LED Indicators Figure 8. Status LEDs overview - All versions IG-0031-00 1.2 Page 12 of 32...
Page 17
® Overall Description Ewon Cosy+ Table 5. On all versions Label Description Reset Button Steady green = reset button is being pressed Power Steady green = unit is powered on User • Blinking green slowly = Unit is ok • Orange pattern = special attention required Digital IN 1 Green = ON : Signal on Input 1 detected Digital Output &...
® LAN Switch Specifications Ewon Cosy+ 4.3. LAN Switch Specifications 4.3.1. Boot Process ® After powering on or requesting a reboot of the Ewon Cosy+, a delay (approximately 2 to 4 sec) is required before the LAN switch feature is fully operational. IMPORTANT ®...
® ® Ewon Cosy+ models Ewon Cosy+ ® 5. Ewon Cosy+ models NOTE ® The Ewon Cosy+ exists in different models in order to adapt to any local internet connection type. ® 5.1. Ewon Cosy+ Ethernet - EC71330 • Order code: EC71330_00MA •...
® IP Address and Access to the Web Configuration Ewon Cosy+ 6. IP Address and Access to the Web Configuration 6.1. Factory Default IP Settings Table 7. Default IP address Characteristics Values LAN IP address 10.0.0.53 LAN subnet mask 255.255.255.0 Gateway 0.0.0.0 NOTICE...
Page 30
® ® Ewon Cosy+ Web Interface Ewon Cosy+ IMPORTANT ® Default login and password are both adm. For security reasons, the Ewon Cosy+ will ask you to change the adm password. ® Methods to configure your Ewon Cosy+: 1. The eCatcher Easy Setup (recommended) This method benefits from the use of a USB stick or SD card that holds a configuration file created inside eCatcher.
® Troubleshooting Ewon Cosy+ 7. Troubleshooting 7.1. Standard Boot Process ® The standard boot of an Ewon Cosy+ takes approximately 2 minutes to complete. During this process, all LEDs are first shortly on ( except BI1 ), then only the PWR LED stays steady green. As soon as the boot process is completed and the unit is ready to be used, the USR LED blinks green slowly to ®...
® ® Reset of the Ewon Cosy+ Ewon Cosy+ Release the reset button. IMPORTANT If you don't release the reset button when the BI1 LED blinks red, you will trigger a reset level 2 ® which will format entirely your Ewon Cosy+.
® ® Reset of the Ewon Cosy+ Ewon Cosy+ 7.2.3. Reset Matrix Table 8. Impact matrix of a reset Reset Level Erased or Reset Preserved ® Impact of a reset level 1: User reset Ewon Cosy+ identification LAN IP address + mask Custom user web site Internet access User Password...
® Appendix Ewon Cosy+ Appendix A. Appendix 1. Main Connector As shown in the image below, the female mating connector is labelled with the appropriate symbols. ® Figure A.1. The Ewon Cosy+ Female connector Table A.1. Labels on main connector Icon Description DO_COM...
® Digital Output & Digital Inputs Ewon Cosy+ Power supply should be separately certified according to UL/IEC 62368-1 with ES1, PS2 output or separately certified to IEC/UL60950-1 with LPS output or Class2 per NEC. Table A.3. Characteristics of the power supply Characteristic Value Power supply voltage...
® Digital Output & Digital Inputs Ewon Cosy+ NOTICE This is a sink output to ground. The transistor acts as a switch ground. Figure A.3. External wiring of the Digital Output 3.1. Possible Features of the DI & DO Wiring the Digital Input and Digital Output allows you to externalize some features (as connectivity condition), as described below: Table A.5.
Need help?
Do you have a question about the Ewon Cosy+ and is the answer not in the manual?
Questions and answers