urmet domus 1083/40 Addendum
Hide thumbs Also See for 1083/40:
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

DS 1083-053
PER LA CONFIGURAZIONE E IL FUNZIONAMENTO
DI DUE CENTRALINI 1083/40 IN MODALITÀ MUTUAMENTE ESCLUSIVA (X-OR)
FOR THE CONFIGURATION AND OPERATION OF TWO 1083/40
SWITCHBOARDS IN MUTUALLY EXCLUSIVE MODE (X-OR) IN 2 VOICE SYSTEM
(La documentazione in lingua francese, spagnola e tedesca è scaricabile dal sito www.urmet.com)
(Manuals in French, Spanish and German can be downloaded from www.urmet.com)
CENTRALINO DI PORTINERIA
CONCIERGE SWITCHBOARD
Sch./Ref. 1083/40
ADDENDUM
CON SISTEMA 2 VOICE
ADDENDUM
1
2
3
ABC
DEF
4
5
6
GHI
JKL
MNO
7
8
9
PQRS
TUV
WXYZ
0
SHIFT
F1
F2
F3
F4
F5
F6
Mod.
1083
LBT 20007

Advertisement

Chapters

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 1083/40 and is the answer not in the manual?

Questions and answers

Summary of Contents for urmet domus 1083/40

  • Page 1 WXYZ SHIFT ADDENDUM PER LA CONFIGURAZIONE E IL FUNZIONAMENTO DI DUE CENTRALINI 1083/40 IN MODALITÀ MUTUAMENTE ESCLUSIVA (X-OR) CON SISTEMA 2 VOICE ADDENDUM FOR THE CONFIGURATION AND OPERATION OF TWO 1083/40 SWITCHBOARDS IN MUTUALLY EXCLUSIVE MODE (X-OR) IN 2 VOICE SYSTEM (La documentazione in lingua francese, spagnola e tedesca è...
  • Page 2: Table Of Contents

    ITALIANO INDICE IntroDuzIone .............................  rIchIamI IStruzIonI operatIve .......................  .1 elenco dei particolari ........................3 . procedura per accedere al menu ....................3 .3 procedura per uscire dal menu ....................... 3 .4 Struttura del menu .......................... 4 .5 procedura di ripristino ai valori di default ..................4 .6 procedura di disattivazione funzione deviazione di chiamata su cordless ........
  • Page 3: Elenco Dei Particolari

    2.1 ELENCO DEI PARTICOLARI PQRS WXYZ SHIFT PQRS WXYZ SHIFT tasto di accensione e spegnimento con led verde tasto di commutazione servizio giorno/notte con led verde tasto per visualizzare l’elenco delle porte rimaste aperte con led rosso tasto attivazione fonia verso posto interno tasto per visualizzare la memoria chiamate dai posti interni con led rosso tasto attivazione comunicazione tra posto esterno e posto interno tasto per chiamate/conferme...
  • Page 4: Struttura Del Menu

    2.4 STRUTTURA DEL MENU Di seguito si riporta, per comodità, la struttura del menù. LINGUA TEMPO OCC. MONITOR ITALIANO (1,10,20,30,...,70S) (0=NO , 1=SI) IN COLONNA S+ S- INTERROMP. (0=NO,1=ES,2=IN,3=T) (0=NO , 1=SI) (0=NO , 1=SI) PASSWORD TIPO COD. F1 FUNZ. 000000 (0=FISICO, 1=LOGICO) (0=NO,1=SPEC,2=TEL)
  • Page 5: Configurazione Parametri Impianto

    CONFIGURAZIONE PARAMETRI IMPIANTO Al fine di utilizzare due centralini nello stesso impianto è necessario assegnare a ciascuno di essi un identificativo univoco. per il corretto funzionamento assicurarsi che entrambi i centralini abbiano il parametro In coLonna impostato a 0. In caso di errata impostazione su uno dei due centralini il trasferimento di competenza non sarà eseguito. IN COLONNA (0=NO , 1=SI) Nel menu di configurazione il parametro SWI ID #, selezionabile con i tasti...
  • Page 6: Installazione Dei Centralini

    Il centralino non attivo ha una sola modalità di funzionamento in cui non fa nulla tranne che ricevere la competenza (se richiesto dal centralino attivo). Il centralino non attivo può essere: • spento (il LeD verde del tasto [on/off 1] è lampeggiante lento) N.B.
  • Page 7: Primo Centralino

    5.1 PRIMO CENTRALINO • assicurarsi che il primo centralino sia connesso alla propria borchia. • Verificare che sul primo centralino il parametro IN COLONNA sia impostato a 0. • Verificare che sul primo centralino il parametro SWI ID # sia impostato a 00 ed uscire dalla configurazione.
  • Page 8: Configurazione Di Impianto Con 1 Sola Postazione Di Chiamata

    7.1 CONFIGURAZIONE DI IMPIANTO CON 1 SOLA POSTAZIONE DI ChIAMATA postazioni di postazioni di interfaccia chiamata interfaccia chiamata di colonna secondarie di colonna secondarie alimentatore alimentatore d = 50 m max distributore alimentatore centralino 00 distributore alimentatore centralino 01 alimentatore postazione di chiamata principale N.B.
  • Page 9: Configurazione Di Impianto Con Massimo 4 Postazioni Di Chiamata

    7.2 CONFIGURAZIONE DI IMPIANTO CON MASSIMO 4 POSTAZIONI DI ChIAMATA postazioni di postazioni di chiamata interfaccia interfaccia chiamata secondarie di colonna di colonna secondarie alimentatore alimentatore distributore centralino 01 alimentatore centralino 00 interfaccia alimentatore posti esterni alimentatore alimentatore postazioni di chiamata principali N.B.
  • Page 10: Introduction

    ENGLISh CONTENTS IntroDuctIon ........................... 10 referenceS to operatIve InStructIonS ................. 10 .1 List of details ..........................11 . how to access the menu ......................11 .3 how to exit the menu ........................11 .4 menu structure ..........................1 .5 how to restore default settings ..................... 1 .6 how to deactivate call diversion to cordless ................
  • Page 11: List Of Details

    2.1 LIST OF DETAILS PQRS WXYZ SHIFT PQRS WXYZ SHIFT 1 – on/off button with green led 2 – Day/night mode switching button with green led 3 – button used to display the list of the doors left open with red led 4 –...
  • Page 12: Menu Structure

    2.4 MENU STRUCTURE the menu structure is show for the sake of simplicity below. LANGUAGE BUSY TIME MONITOR ENGLISH (1,10,20,30,...,70S) (0=NO , 1=YES) IN RISER S+ S- INT. COMM. (0=NO,1=EX,2=IN,3=A) (0=NO , 1=YES) (0=NO , 1=YES) PASSWORD CODE TYPE F1 BUTTON 000000 (0=PHYSIC, 1=LOGIC) (0=NO,1=SPEC,2=TEL)
  • Page 13: System Parameter Configuration

    SySTEM PARAMETER CONFIGURATION a univocal ID must be assigned to each switchboard to be able to use them in the same system. for correct operation, make sure that the In rISer parameter is set to 0 for each switchboard. competences will not be transferred if either switchboard is not set correctly. IN RISER (0=NO , 1=YES) The SWI ID # parameter, which can be selected using the...
  • Page 14: Switchboard Installation

    the inactive switchboard has only one operating mode and can only receive competences (if required to do so by the active switchboard). the inactive switchboard may be: • off (green LeD of the [on/off 1] button blinks slowly) N.B.: Only the switchboard which is active and on can transfer competencies to the inactive switchboard. transfer of competences can be requested by the active switchboard when it is in stand-by mode, i.e.
  • Page 15: First Switchboard

    5.1 FIRST SWITChBOARD • Make sure that the first switchboard is plugged into its telephone socket. • Make sure that the IN RISER parameter of the first switchboard is set to 0. • Check that the SWI ID # parameter on the first switchboard is set to 00 and exit configuration. 5.2 SECOND SWITChBOARD •...
  • Page 16: System Configuration With One Calling Station

    7.1 SySTEM CONFIGURATION WITh ONE CALLING STATION secondary secondary column column call stations interface call stations interface power supply power supply d = 50 m max distributor power supply switchboard 00 distributor power supply switchboard 01 power supply main call station N.B.: The maximum extension of the system between calling station and the last riser interface must also include the connection segments (d) between distributor and switchboard.
  • Page 17: System Configuration With Up To Four Calling Stations

    7.2 SySTEM CONFIGURATION WITh UP TO FOUR CALLING STATIONS secondary secondary column column call call interface interface stations stations power supply power supply distributor switchboard 01 power supply switchboard 00 door units power supply interface power supply power supply main call stations N.B.: The maximum extension of the system between calling station interface and the last riser interfaces must also include the connection segments (d) between distributor and switchboard.
  • Page 18: Schemi Impianto

    NOTE LEGATE AGLI SChEMI VD.007 - Tasto chiamata al piano. VV.004 - Nota bene: sullʼultima interfaccia di colonna non rimuovere il ponticello tra i morsetti Z. VV.008 - Impostare il dip-switch “1” in posizione OFF. VV.010 - Configurazione Parametri Centralino: - Impianto in colonna: 0(NO).
  • Page 19 NOTES ON DIAGRAMS VD.007 - Floor call button. VV.004 - Note: on the last column interface do not remove the jumper between terminal pins Z. VV.008 - Set the dip-switch “1” to OFF position. VV.010 - Parameters configuration Switchboard: - System in column: 0(NO). - Associated monitor: 1(YES).
  • Page 20 LINE ~ LINEA ~ LINE OUT LINE ~ Sch./Ref.1083/20A (VX.008) LINE LINE BORCHIA A CORREDO CENTRALINO SECONDARIO/SECONDARY SECONDARIO/SECONDARY SWITCHBOARD WIRING Sch./Ref.1083/40 Sch./Ref.1732/41 (VV.010) JUNCTION BOX SUPPLIED (Nero) LINE ai moduli successivi LINE LINE to following modules (Rosso) POWER LINE IN Sch./Ref.1083/55...
  • Page 21 Connection of N risers of max. 4 backbones each, backbones with more video door phones and door phones, to 1 main video outdoor station and to 2 switchboards with video module. Each group is additionally connected to 1 or 2 secondary video outdoor stations. COLONNA/RISER 2 DORSALE DORSALE...
  • Page 22 "A" LINE 2 Sch./Ref.1083/20A (VX.008) LINE OUT LINEA ~ LINE LINE LINE ~ "I" "II" BORCHIA A CORREDO CENTRALINO SUPPLIED SWITCHBOARD Sch./Ref.1083/40 Sch./Ref.1732/41 WIRING JUNCTION BOX (Nero) LINE SECONDARIO/SECONDARY SECONDARIO/SECONDARY LINE LINE (Rosso) POWER LINE IN (VV.010) ai moduli successivi MAX.
  • Page 23 Name tag lighting (VX.014) SECONDARIO/SECONDARY SECONDARIO/SECONDARY (VX.008) LINEA ~ LINE ~ LINE OUT LINE LINE BORCHIA A CORREDO CENTRALINO SUPPLIED SWITCHBOARD Sch./Ref.1083/40 Sch./Ref.1732/41 WIRING JUNCTION BOX (Nero) LINE LINE LINE (Rosso) POWER LINE IN (VV.010) Sch./Ref. LINE 1 1083/55 LINE 2 Sch./Ref.1083/20A...
  • Page 24 DS 1083-053 LBT 20007 urmet S.p.a. area tecnica 10154 torIno (ItaLy) servizio clienti +39 011.3.39.810 vIa boLogna 188/c http://www.urmet.com telef. +39 011.4.00.000 (rIc. aut.) e-mail: info@urmet.com +39 011.4.00.300 - 33...