1. SAFETY WARNINGS Warning: 1. Caution! Exhaust gases are toxic. Do not operate the generator in a room without a ventilation system! 2. Children must be protected by keeping them at a safe distance from the generator! 3. Generator filling is not permitted during operation! 4.
Page 4
authorized service center. The accessible surfaces may be hot when operation. Avoid coming in contact with them. Always use gloves when handle the tool. Protect children by keeping them at a safe distance from the generating set. Fuel is combustible and easily ignited. Do not refuel during operation. Do not refuel while smoking or near naked flames.
Page 5
When using or transporting the generator, be sure to hold the generator upright, otherwise the fuel may leak from the carburetor or fuel tank. Electrical Safety Check before each use that the load to be connected does not exceed the power output of the generator. To avoid electric shock, follow the instructions below: Do not touch the generator with wet hands.
Carbon monoxide (CO) danger Exhaust emissions are harmful to health of body. Do not connect with an electrical supply Disposal symbol Guarantee noise emission 2. YOUR PRODUCT DESCRIPTION 1. Handle 8. Air filter 2. Tank cap 9. AC socket outlet 3.
Technical data MODEL G800-A Generator Rated outer power (PRP) 0,65 kW Max power 0,7 kW, S2 : 5min Voltage 230 V~ Rated current 2.8 A Frequency 50 Hz Phase Single Capacity CosΦ = 1.0 Degree of protection IP23M Length x Width x Height...
Page 8
The diagram of the position of the center of gravity of the generator, the location indicated by the arrow is adapted to the position to transport the machine, and put it in another way is prohibited. STARTING Put the gas lever on the ON position. Put the choke lever on the position 1.
SECURITY Push the switch to restart Reduce the charge if the security has been triggered 1= RESET 2 = OFF 4. MAINTENANCE Candle: o Every 50 hours or at least once a month. o Remove it. o Remove carbon dioxide. o Check the color (normal color = light brown).
To dispose of residual fluids, proceed as follows: Open the fuel tank Drain the fuel from the fuel tank Empty carburetor fuel The disposal of the residual fluid must be made in a safe place. 5. STORAGE Empty the tank and carburetor.
ZI, 32 RUE ARISTIDE BERGES – 312070 CUGNAUX – FRANCE Declare that this machine: POTABLE PETROL GENERATOR Model: G800-A Serial number: 20220528472-20220529227 Is in conformity with the directive « machine » 2006/42/CE and to regulations transposing it Also in conformity with the following directives:...
8. WA R R A N T Y WARRANTY The manufacturer guarantees the product against defects in material and workmanship for a period of 2 years from the date of the original purchase. The warranty only applies if the product is for household use. The warranty does not cover breakdowns due to normal wear and tear.
9. P R O D U C T FA I L U R E WHAT TO DO IF MY MACHINE BREAKS DOWN? If you bought your product in a store: a) Empty the fuel tank if your product has one. b) Make sure that your machine is complete with all accessories supplied, and clean! If this is not the case, the repairer will refuse the machine.
10. WA R R A N T Y E X C L U S I O N S THE WARRANTY DOES NOT COVER: • Start-up and setting up of the product. • Damage resulting from normal wear and tear of the product. •...
Page 15
BUILDER SAS 32, rue Aristide Bergès - ZI 31270 Cugnaux – France Made in PRC 2022...
Need help?
Do you have a question about the G800-A and is the answer not in the manual?
Questions and answers