Should he end up in a dead end please contact Lillnord on + 45 8780 3130 In order to obtain a PG-100 unit that daily work efficiently with high quality of the finished fermented dough, follow Lillnord recommendations for daily, monthly and annual maintenance, see page 12—Maintenance in Detailed Troubleshooting /...
Table of contents Page POWER SUPPLY In general control error occurring in the power supply MOISTURE General occurring error in connection with the drying of products, uneven proofing and too little humidity STEAM UNIT Steam unit running over, will not stop filling in water HEAT The system does not heat or heats insufficiently GENERAL...
ERROR - POWER SUPPLY: 1 System does not start in pos. 1 Dead End? and 2. Lamp does not light. Fuse blown CONTACT LILLNORD Replace the fuse Tlf +45 8780 3130 2 Flap for the drain valve not closed Close flap...
ERROR - MOISTURE: 1 Not enough moisture 5 Relay does not pull Operating Lamp OFF Relay defective Hygrostat set incorrectly Replace relay Normal setting about 80-90% RH 2 Hygrostat defective 6 Check the power supply Replace hygrostat Page 4, para. 1-6 3 Operation Lamp ON 7 Too many water refills Steam unit does not steam sufficient.
Page 6
Flusch the steam tank through Draining minimum 1 to 2 liters OK or 9a Clean the steam tank inside Dead End? CONTACT LILLNORD Tlf +45 8780 3130 10 Kalk coating on the electrodes Clean the electrodes 11 Electrodes worn (New 200 mm)
Check para. 9, 10, 11 and 12 on Must be 3 to 4 amps on each phase page 6 OK or 4 Special ciúrrent relay 959 set too Dead End? high or defective Normal setting 4-5 amp. CONTACT LILLNORD If defective, replace relay Tlf +45 8780 3130...
ERROR - HEAT: 1 Heat does not work, operation 5 Check power supply lamp ON. See para. page 4 Check thermostat for errors. Recommended setting 30-40° C Fuse blown. Replace fuse 2 Thermostat defictive 6 Heat disconnected on overheating Replace thermostat fuse Contactor K1 defective Fan defective...
Page 9
9 Switch position: Pos. 1 - Moisture has top priority Pos. 2 - Moisture and heat have sa- me priority 10 Check power supply See page 5, para. 1 to 6 OK or Dead End? CONTACT LILLNORD Tlf +45 8780 3130...
ERROR - GENERAL: 1 Door is open and has been open Dead End? for a while Keep the door closed CONTACT LILLNORD Tlf +45 8780 3130 2 Door gasket defective Replace door gasket 3 a side facing a oven to hot...
MAINTENANCE TO ACHIEVE A SMOTH OPERATION —————————— LILLNORD RECOMMEND THE FOLLOWING DAILY: Draining the steam unit MONTHLY: Switch off the power supply voltage and flush the steam tank through. Use a water hose - flush through the drain valve ANNUAL - OR AS NEEDED: Cleaning the steam tank inside (See page 6 para.