E09
00009
Over charge error
E10
0000A
Level 1 over discharge error
E11
0000B
Level 2 over discharge error
Level 1 over discharge current
E12
0000C
error
Level 2 over discharge current
E13
0000D
error
E14
0000E
Over charge current error
E15
0000F
Software start failure error
E16
00010
Pre-charge time-out error
MOS temperature sensor failure
E17
00020
error
Battery cell temperature sensor
E18
00030
failure error
Battery discharge overheated
E19
00040
error
E20
00050
Battery charge overheated error
Battery discharge low
E21
00060
temperature error
Battery charge low temperature
E22
00070
error
Battery discharge, MOS
E23
00080
overheated error
Battery charge, MOS overheated
E24
00090
error
E25
000A0
Soft-start circuit overheated error
E26
000B0
Storage error
E27
000C0
Discharge fuse failure error
E28
000D0
Charge fuse failure error
E29
000E0
Level 3 over current error
E30
000F0
Level 4 over current error
E31
00100
Setting error
Controller phase wire over
E33
00300
current error
LLEXETER LTD - UNITS 15-18 GREENDALE BUSINESS PARK - WOODBURY SALTERTON - DEVON - EX5 1EW - UNITED KINGDOM
COMPANY NO: 4940600 / VAT REGISTRATION NO: GB825156925 TEL: 01395 233128
5.2 Diagnostic Codes
1. Charging voltage is higher than single battery cell's
over charge protection voltage 4250mV.
2. Misinformation of BMS
Battery charge too low
Battery discharge current too high
Battery discharge current too high
Charging current is too high
Electrical overload when connecting the battery
1. Failure of the charger or incorrect battery charger
2. BMS failure.
MOS Temperature sensor failure
Battery cell temperature sensor failure
Battery overheating while being discharged
Internal battery temperature too high while charging
Internal battery temperature too low while riding
Internal battery temperature too low while charging
It's caused by the overheated MOS when the battery pack
is discharging.
It's caused by the overheated MOS when the battery pack
is charging.
Soft start system overheating
Internal fault in the motor control unit
Not applicable
Not applicable
Short circuit in the electrical wiring
Short circuit in the electrical wiring
Production fault in the motor controller
Controller phase wire current is equal or greater than the
protection value.
LLEXETER.CO.UK
Discharge and recharge the battery
Re-start the bike
Charge the battery immediately.
Reduce power usage for 1 mile
Reduce power usage for 1 mile
Check wiring and systems for short circuit
Check the charger for faults
Replace the charger and try again
Please follow the owner's manual to turn on
the powertrain and start riding.
1. Replace the charger and try again
2. If 1. does not work, replace the battery
Re-start the bike
Re-start the bike
Stop riding and allow the battery to cool
before continuing to ride the machine
Stop charging and allow the battery to cool
before attempting to charge the battery
Stop riding and return the machine to a warm
area and wait for the internal temperature to
rise before continuing to use the machine
Stop charging and return the battery to a warm
area and allow the internal temperature to rise
before charging
Stop riding the machine until the temperature
has lowered
Stop charging the battery until the temperature
has lowered
Do not ride the machine until the overheat
protection has reset
Send the bike to the nearest dealer to repair.
/
/
Inspect and eliminate the short circuit.
Inspect and eliminate the short circuit.
Replace the motor controller assy.
1. Turn off the bike, and switch off the circuit
breaker. Then, check the whether the motor
phase wire terminal are loose, or broken.
Check whether the motor outlet phase
sequence corresponds to the U / V / W on the
controller. Finally, check whether the
magnetic encoder output wire corresponds to
the yellow, green and blue wires on the
harness assembly.
2. Check the rear wheel and brake for
obstruction or seizure
Error does not prevent riding but prevents
charging. After the re-start, if the error code
persists, replace the battery
Charge the battery immediately.
Check condition of drivetrain including rear
brake, wheel and gearbox for seizure.
Check condition of drivetrain including rear
brake, wheel and gearbox for seizure. Check
wiring and systems for short circuit or failure
Ensure battery is being charged from an
official Talaria charger for the model. Check
wiring and connections. If necessary, replace
the charger.
Ensure the ignition and circuit breaker are in
the "Off" position before connecting the
battery
Ensure the correct battery charger is being used
and test with a replacement if necessary,
otherwise replace the battery.
If the fault persists, replace the battery
If the fault persists, replace the battery
Check condition of drivetrain including rear
brake, wheel and gearbox for seizure. Check
wiring and systems for short circuit or failure
and ensure machine is not overloaded
Ensure the battery is being charged in a well
ventilated area at room temperature. Allow the
battery to cool before attempting to charge
Stop riding and return the machine to a warm
area and wait for the internal temperature to
rise before continuing to use the machine. If
the fault persists when at the correct
temperature, replace the battery
Stop charging and return the battery to a warm
area and allow the internal temperature to rise
before charging. If the fault persists when at
the correct temperature, replace the battery
Check condition of drivetrain including rear
brake, wheel and gearbox for seizure. Check
wiring and systems for short circuit or failure
and ensure machine is not overloaded
Ensure the battery is being charged in a well
ventilated area at room temperature. Allow the
battery to cool before attempting to charge
Do not ride the machine until the overheat
protection has reset
Check all wiring connections, battery
connections and wiring for faults and repair if
necessary. If fault persists, replace the
controller
Test all wiring and connections for failure or
short circuit. Check motor phase coils for fault
or short circuit.
Test all wiring and connections for failure or
short circuit. Check motor phase coils for fault
or short circuit.
Check motor phase wires and Hall sensors for
correct operation. If fault persists, replace the
motor

Advertisement

loading

This manual is also suitable for:

Sting tl45