6. Electrical Wiring Diagram
6. Electrical Wiring Diagram
Wall Mounted Type
SPI
S-Plasma ion
M-BLDC
BLDC Motor
NOTE
This wiring diagram applies only to the Indoor unit.
Symbols show as follow : blk: black, red: red, blu: blue, wht: white, yel: yellow, brn: brown, sky: skyblue: grn: green
For connection wiring indoor-outdoor transmission F1-F2, indoor-wired remotecontroller transmission F3-F4.
Protective earth(screw)
Electronic Expansion Valve
Thermistor EVA IN(10K)
ROOM
Thermistor ROOM in (10K)
Thermistor EVA OUT(10K)