Page 4
Part 1 | Before You Begin Part 2 | Product Overview Part 3 | Name of Each Part Part 4 | How to Use Part 5 | Error Table Part 6 | Simple Troubleshooting Tips Part 7 | Product Specifications...
Thank you for purchasing the H2-BP(model name of Automated Electronic Sphygmomanometer made by Charmcare Co., Ltd. ("Charmcare")} ). For the safe operation of this product, it is recommended that you read this user manual thoroughly before using. Purpose This sphygmomanometer is a "Medical Device" suitable for IEC80601-2-30 and is an electronic device that measures blood pressure indirectly (non-invasive).
Tel: +82-70-4756-8355 Fax: +82-2-862-5065 Website http://www.charmcare.com E-mail: cs@charmcare.com Definition of Terms The user must follow all warnings and precautions. ● Warning: “Warning” is used to refer to factors, which, when ignored, may result in severe and/or fatal injuries and property damage .
Page 7
Store below an altitude of of dust and debris, the product by yourself. 3,000 m and a temperature particularly metallic objects. Charmcare is not liable for any problems below 70 ℃ . that may occur should you attempt to do so.
Safety Precautions Do not shock or drop this product. ● Do not measure without wearing this product on your wrist. ● Dispose of body, parts and accessories of this product according to local regulations. ● For specific information about your own blood pressure, consult with your physician.
Page 9
· Please do not adjust dosage on your discretion according to the measurement results. · Please take your medicine according to your physician's prescription. · Diagnosis and treatment of hypertension is only possible with your physician. · Please consult with your physician before using, if you have any of the symptoms below.
Page 10
· Please do not use in a location where there is moisture or a risk of splashing water over this product which may damage the product. · Please keep this product clean. If this product is causing skin irritation due to sweat or contamination, stop using it and consult with your dermatologist.
Page 11
· Please consult with your physician for specific information about your own blood pressure. · Self-diagnosis or self-treatment according to measurement results is dangerous. · Please consult with your physician if you have the symptoms following below. - In case of wire ablation - In cases of severe blood disorders or internal bleeding due to compression.
Page 12
· Use this product to measure your blood pressure regularly, record your results and consult with your physician. · When measuring blood pressure, the position of the cuff should be accurately set at the radial artery, and the cuff should be at the same level as your heart.
Page 13
Product Symbol Description The serial number that identifies the object. Date of manufacture Manufacturer Warning Caution Instruction for User Manual Type of applied part WEEE Mark...
Maintenance and Cleaning Wearable blood pressure monitor device can be kept clean using various methods. Avoid any damage or contamina- tion of this product using the methods recommended below. This product is not covered under the guarantee period free of charge in cases of using unauthorized substances ●...
Data Transmission This product emits radio frequencies (RF) in the 2.4 GHz band. Do not use this product in areas where RF is ● restricted, such as on an aircraft or in hospitals. Turn off the Bluetooth® feature of this product when in RF restricted areas .
Page 16
A tool that measures the girth size of the wrist Adjusting Pin Pin to adjust height User Manual A guide for user Quick Start Guide Quick manual for user · Do not swallow accessories. This may result in choking. · Please purchase accessories via Charmcare or it's distributors.
Page 17
Name of each part of wearable blood pressure monitor DESCRIPTION Display Switch 1 Switch 2 Cuff Height-adjusting Hole Band Strap Hook Band Strap Charging Terminal Charging Cable Adjusting Pin Tape Measure · For electrical safety, this product should not be disassembled.
● Be careful because this product is easily damaged by impact. ● Use this product within the range of the ambient temperature and the humidity guided by Charmcare, and store ● it away from dust and flammable materials. Check whether if the external appearance of this product is changed or not.
Page 19
Preparation before wearing Tape Measure for ● measuring wrist circumference (1) Measurement | With the enclosed ‘Tape Measure’, measure the wrist circumference. And check the number and letter (alphabet) that fits the user. Adjusting Pin ● (2) Adjustment | ①...
Page 20
1 to 5 you measured. 6.7 inch~8.7 inch (17 cm ~ 22 cm) * Note: The H2-BP device fits adult wrists from 6.7 inch to 8.7 inch (17 cm to 22 cm) in circumference. Make sure the hard part ●...
· Do not measure on a wrist where the radial artery is blocked. Measurement errors may occur. · Blood pressure can differ between the right and left wrists, and readings can be different. Charmcare recommends always using the same wrist when measuring blood pressure. Consult with your physician to determine which wrist for taking your measurements.
Page 22
Accurate measurement posture If the position of the wrist is different from the height of the heart, the blood pressure results change due to the weight of the blood itself. The results show that when the wrist position is higher than the heart, the blood pressure value is lowered and vice versa.
Power Press switch 1 for more than 2 seconds. ● Blood pressure measurement ① While wearing the product, press switch 1. ② As pressure is applied to the wrist, the current pressure is displayed on the screen.
Page 24
③ When the measurement is completed, the measured blood pressure result is displayed. Repeated measuring at intervals of about 10 minutes. · If the band strap is loose, blood pressure measurement may not be possible. · If the cuff is not positioned over the radial artery, a blood pressure measurement error may occur.
Display clock ① Press switch 2. ② The current time is displayed. Display of stored blood pressure measurements ① Press switch 2 twice. ② The blood pressure measurement ③ The blood pressure date, time and index values are measurement result is displayed.
Page 26
Setting switch description ◀ Switch 1: To complete the change ◀ Switch 2: To change a menu or value...
Page 27
How to set up ② Selected menu:Press switch 2 to move to selected menu and press switch 1 to complete menu selection. ③ Settings change:Press switch 2 to change the selected setting, then press switch 1 to complete the setting change.
Page 28
Automatic clock display mode by operation ① Select the AUTO menu. ② When ON is selected, the screen auto-on by motion is activated. ③ When OFF is selected, the screen auto-off by motion is activated. If the screen auto-on is set, the battery may run out quickly.
Date and Time Setting ① Select from the TIME menu. ② Set the year. ③ Set the month, day ④ Set the hour, minute This function is a menu to set the date and time if you cannot synchronize with the app. When you synchronize with the app, the time is automatically set to the date and time on your mobile phone, so you do not need to set it manually.
Delete Data ① Select from the DEL menu. ② If you select YES, the data will be deleted. If you delete the data, it will not be possible to recover it, so please be careful before deleting data. Count ①...
How to use the charger Lightly place the charging cable on the charging terminal as shown in the figure. Charging terminal Charging cable · Do not pull the charging cable. When handling the charging cable: - Do not damage it.
· This application allows you to correctly transfer data from your H2-BP to your smartphone. · Be aware that Charmcare will not be held responsible for any loss of data or information in the app. · If you change your smart device that was paired with your monitor, delete the pairing information from your old...
Page 33
Do not move while taking the measurement. Wear the cuff correctly and refer to the instructions. Poor cuff condition Check the cuff is inflating properly by pressing the switch 1. Please contact Charmcare or it's distributor.
Page 34
Refer to measurement Part 10 Q&A. measurement. Press the measurement switch again to newly begin from scratch. Charge the battery. Other situations If the treatments above do not solve the problem, please contact Charmcare or it's distributor.
Page 35
160 mAh 1 h 30 min 3 days; decreasing with the increase of measurements. 1 year Measurable Girth Size of Wrist 6.7 ~ 8.7 inch (17 ~ 22 cm) Measurement Range: 30 mmHg ~ 60 mmHg / Accuracy: ±5 mmHg Measurement Method: Oscillometric/ Measurement Time: 30 ~ 80 seconds Range: 40 bpm ~ 180 bpm/ Accuracy: ±5%...
Page 36
Micro pump 10 ℃ ~ 40 ℃ 0% ~ 85% -20 ℃ ~ 70 ℃ 10% ~ 85% How to store and manage this product after use ① Do not store it near water. ② Do not store it under the influence of air pressure, temperature, humidity, wind or the like.
Classification of BP(Blood Pressure) Categories for BP in Adults* * Individuals with Systolic BP and Diastolic BP in 2 categories should be classified into the higher BP category. BP stands for blood pressure. Blood Pressure should be measured on 2 or more occasions to be classified in a category.
Page 38
There is approximately ±10 mmHg difference between the measured values of the wrist and upper arm blood pressure when you are in a good condition. However, the blood pressure of the upper arm and wrist value may vary significantly immediately after excersing or bathing.
Page 39
In relation with meals generally there is no significant difference between the preprandial upper arm and wrist blood pressure as well as the postprandial one. However, in case of entering a bath with a high water temerpature, the blood pressure goes high due to the contraction of the blood vessels of the skin.
Page 40
Differences in blood pressure according by posture There is a distinct blood pressure difference between lying down, sitting and standing. The blood pressure of the standing posture is about 5 mmHg higher than that of the lying down posture on diastole while the blood pressure of the lying down posture is 8 mmHg higher than that of the sitting posture.
Page 41
Measured results at home vs. at the hospital In some cases, the results of the blood pressure measured at home may be to the maximum extent of 20 ~ 30 mmHg lower than those of the blood pressure measured at the hospital because you feel nervous there.
Page 42
The measured results for each intraday measurement Are you always measuring under th same conditions? Nonstop measuring of the blood pressure in one day is likely to give you different results, therefore it must be done under the same conditions. Ensure you are in the correct guided posture.
Page 43
Pain and numbness by tightening the cuff This product needs to be tightened until the arterial blood flow is temporarily stopped. In such a case, you may feel pain or numbness. However, you will be ok when you take it off for a while.
Page 44
Automated Electronic Sphygmomanometer Oct. 26, 2017 Charmcare Co., Ltd. www.charmcare.com Charmcare is not responsible for loss of use or any indirect or incidental damages or any other losses.
Page 45
Manufacturing license number: 2130 Product License number: 17-4808 FDA Registered Establishment Number : 3006056594 Product Name: Automated Electronic Sphygmomanometer, Model Name: H2-BP Packing unit: ea, Weight: 46 g Internal battery: LI-ION POLYMER, 3.7 V, 160 mAh Production from electrical shock: Internal power type product/BF type...
Page 46
FCC ID: 2AUYU-4A01 FCC Information to User This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.