6/21
Ratings and dimensions
Description
Field wiring material (material;
conductor temperature; class)
Output voltage
Output current
Output frequency range
12)
Power dissipation at continuous
current and continuous DC bus
power respectively
13)
Bosch Rexroth AG R911319657_Edition 09
HCS02.1E-
Symbol
Unit
W0012-_-03
U
V
out
I
A
4.5
out
f
Hz
out
P
W
80.00
Diss_cont
1) 2) 3)
Housing dimension; see also related dimensional drawing
4) 5) 6)
See fig. "Air intake and air outlet at device"
7)
Observe supply voltage for motor holding brake
8)
See information on "Rated power consumption control voltage
input at U
N3
9)
Mains input L1, L2, L3 (for HMV and HCS only); For use on a
solidly grounded wye source only.
10)
Use listed AC input line fuses (class J; 600 V AC). Suitable for
use on a circuit capable of delivering not more than 42000 A
symmetrical amperes, 500 Volts maximum (HMV, HCS02,
HCS04.2 480 Volts maximum). If using inverse-time circuit
breakers or type E combination motor controllers instead of
recommended fuses, see UL 508C section 45.8.2.
11)
Copper wire; PVC-insulation (conductor temperature 90 °C;
T
≤ 40 °C) in accordance with NFPA 79 chapter 12 and
a
UL 508A chapter 28
12)
Depending on switching frequency which was set in parameter
P‑0‑0001
13)
Plus dissipation of braking resistor and control section
Tab. 2-1:
HCS - UL ratings and dimensions
Rated power consumption control voltage input at U
Plus motor holding brake and control section, plus safety option
IndraDrive Drive Controllers Power Sections HCS02
HCS02.1E-
HCS02.1E-
W0028-_-03
W0054-_-03
Cu; 60/75 °C; 1
3 x AC 0...530
12.0
0...1600
130.00
270.00
Latest amendment: 2019-02-20
"
HCS02.1E-
W0070-_-03
20.6
28.0
300.00
eff
N3