Transition Networks CPSMP-210 User Manual

48vdc power supply, 24vdc power supply

Advertisement

Quick Links

CPSMP-210
48VDC Power Supply
&
CPSMP-220
24VDC Power Supply
PointSystem™ Chassis:
CPSMC18xx-xxx accessory
CPSMC19xx-100 accessory
User's Manual
33187.C

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CPSMP-210 and is the answer not in the manual?

Questions and answers

Summary of Contents for Transition Networks CPSMP-210

  • Page 1 CPSMP-210 48VDC Power Supply & CPSMP-220 24VDC Power Supply PointSystem™ Chassis: CPSMC18xx-xxx accessory CPSMC19xx-100 accessory User’s Manual 33187.C...
  • Page 2: Table Of Contents

    CPSMP-210 48VDC and CPSMP-220 24VDC Power Supplies Table of Contents Cautions and Warnings Definitions ..........3 Cautions and warnings in this manual .
  • Page 3: Description

    MPORTANT • • The CPSMP-210 and CPSMP-220 power supply can replace an existing DC power supply. Either can be installed as the redundant power supply in an AC- or DC- powered PointSystem chassis. CAUTION: While installing or servicing the power supply, wear a grounding device and observe all electrostatic discharge precautions.
  • Page 4: Configuring Two Power Supplies In One Chassis

    CPSMP-210 48VDC and CPSMP-220 24VDC Power Supplies Installation—continued Configuring two power supplies in one chassis To set up power supply redundancy, set one power supply to master, (which supplies power to the entire chassis) and the other to slave. In this mode, the slave power supply is in stand-by mode and takes over in the event of a master power-supply failure.
  • Page 5: Power Source Circuit Requirements

    CPSMP-210 48VDC and CPSMP-220 24VDC Power Supplies Installation—continued Power source circuit requirements The CPSMP 210 and 220 power supplies must be connected to a Safety Extra Low Voltage (SELV) circuit. The installer must first determine circuit characteristics; for example, limited current, and hazardous energy levels, etc., and then install the power supply in accordance with local and national electrical codes.
  • Page 6: Maintenance

    CPSMP-210 48VDC and CPSMP-220 24VDC Power Supplies Maintenance WARNING: Do not connect the power supply module to the external power source before installing it into the chassis. Failure to observe this warning could result an electrical shock, even death. Replacing the power supply Note: The power supply module can be hot swapped (i.e., swapped while the chassis...
  • Page 7: Technical Specification

    CPSMP-210 48VDC and CPSMP-220 24VDC Power Supplies Technical Specification For use with Transition Networks Model CPSMP-210, CPSMP-220, or equivalent. Standards: FCC & CISPR Class A & B; CE Mark Dimensions: 8.3" x 8.4" x 2.7" (211 mm x 211 mm x 69 mm) Weight: 1 lb.
  • Page 8: Contact Us

    Regulation: EMC Directive 89/336/EEC Purpose: To declare that the CPSMP-210 and CPSMP-220 to which this declaration refers is in conformity with the following standards: CISPR 22: (1997) w/A1: 2000 Class A & B; EN 55022: (1998) w/A1: 2000 & A2: 2003 Class A & B; EN 55024:1998 w/A1: 2001 I, the undersigned, hereby declare that the equipment specified above conforms to the above Directive(s) and Standard(s).
  • Page 9 CPSMP-210 48VDC and CPSMP-220 24VDC Power Supplies Trademark notice All trademarks and registered trademarks are the property of their respective owners. Copyright restrictions © 2000, 2004-2005 Transition Networks. All rights reserved. No part of this work may be reproduced or used in any form or by any means—...