WHERE TO RUN CABLE .............. 5 WHAT CABLE TO USE ? .............. 5 MAXIMUM LENGTH FOR CABLE RUNS ........6 INSTALLATION OF SYSTEM ONE MINI ......... 8-11 INSTALLATION OF DOOR/GATE STATIONS ......12 INSTALLATION OF AUXILIARY INPUT JACK ......12 POWER SUPPLY ................
CABLE FUNCTIONS GENERAL INFORMATION CAUTION: Failure to use The following general procedures specified cable may cause must be observed in relation to the POS - 15 VDC (RED) problems with the performance of location and installation of System May measure from 13.8V to 15.5 VDC with respect to 0V depending on voltage the system and will void warranty on One Home Communication drop due to cable length.
Procedure LOCATION OF EQUIPMENT 4) Repeatedly press the Select 1) Press the Program button button until the desired voltage (PROG) – The red LED illuminates output option is displayed. ROOM STATIONS installed prior to lining/tiling of the and the current chime is played. walls and the tiles will need to be Careful consideration must be given 5) Press the Program button again...
Suggested locations are kitchen The Input Jack should be installed CHANGING THE CHIMES cupboards, pantry, bedroom in a wall near the location where the wardrobes etc. The chime melody can be changed to any one of nine options by means of the external music source is to be two programming switches (SEL &...
Note: This pot should be adjusted so the Digit formats. it is recommended that ‘Valet Cable’ Intercom cables should be run as chime volume comes through at an be used on all new installations. far away from AC wiring as...
PROGRAMMING FM Aerial Run the 300 ohm FM Ribbon antenna supplied with the master For the purpose of Select Calling DOUBLE DIGIT CODING from the master to the highest point (Calling individual or grouped in the roof. If using coaxial cable to stations), each station must be Double Digit Format is a connect to an alternative 75 ohm...
ROOM STATION STATION and orange wires back to white POWER SUPPLY SUPPLY outer sheath of valet cable. VALET INTERCOM CABLE Do not connect green and orange NOTE: For 6 Wire Systems INPUT JACK INPUT JACK FIGURE 8 CABLE wires of door station cable at room - Connect Green &...
PC Board. A composite 3-gang box can be used The Terminal Block must be to house the System One MINI. connected exactly as shown in Fig. 4. If using Valet cable, the Attach the 3-gang electrical box Red wire should be on the to a wall stud at desired location.
Page 10
Fig. 1b Install the terminal block. See Fig. 1 for how to wire the terminal block. Wiring configurations for Valet Cable and Cat5 Cable have both been provided. (Fig. 1b) Also shown in the figure 1 is the proper location to install the 220K resistor.