Summary of Contents for Automatic Technology TEMPO ATS-2V3
Page 1
Tempo & Syncro Sectional Door Opener Installation Manual TEMPO ATS-2V3 SYNCRO ATS-3V3 SECTIONAL DOOR OPENER SMART SECTIONAL DOOR OPENER Doc # 160487_01 Released 15/12/22...
Disconnect the power cord from mains power before making any repairs or removing covers. Only experienced service personnel should remove covers from the opener. • If the power supply cord is damaged, it must be replaced by an Automatic Technology service agent or suitably qualified person. •...
Page 4
ATS Series Installation Manual 1. Safety Warnings! (for operation) This automatic garage door opener is designed and tested to offer safe service provided it is installed and operated in strict accordance with the following safety warnings. Failure to comply with the following instructions may result in death, serious personal injury or property damage.
ATS Series Installation Manual 2. Before you Begin 2.1 Examine the conditions in the garage: a. Look at the ceiling: i. Is it plastered? The opener is mounted to a perforated angle which MUST be securely fastened to a structural support. You will need to locate the structural beams in the ceiling which are generally 400mm apart.
ATS Series Installation Manual 4. Kit Contents 1 x ATS drive unit Safety Beam Kit (Syncro only) PLUS 1 x Bent arm door attachment 5. Wireless Safety Beams 1 x Track Hardware Kit 1 x Wall Transmitter 1 x Pre-Assembled track 2 x Transmitters 6.
ATS Series Installation Manual 6. Fit the Opener 6.1 Secure C-Rail to Opener: a. Remove the Opener from the box. b. Remove the track and hardware kit from the rail box. c. Locate and insert the shaft of drive unit into the C-Rail’s sprocket.
ATS Series Installation Manual 8. Perforated Angle (Not supplied) 8.1 Attach Perforated Angle or equivalent a. Measure across the ceiling from the centre point 3175mm (+/- 150mm) to find a supporting beam. b. Create a perforated angle which best suits your site. Use a hack saw to cut the L shape metal strips. Secure the perforated angle to a supporting beam using diagrams shown below.
ATS Series Installation Manual 10. Safety Beam Kit (ATS-3 Only) WARNING! The Opener must be fitted with Safety Beams if: • the closing force at the bottom edge of the door exceeds 400N (40kg) and/or; • the opener has a smart device fitted to operate the door, when not in line-of-sight. CAUTION! The Safety Beam must be installed and connected before the travel limits are set.
ATS Series Installation Manual 11. Specifications Technical Specifications SYNCRO TEMPO ATS-3V3 ATS-2V3 Rated voltage range: 230V - 240V 230V - 240V Rated frequency: 50Hz 50Hz Rated power input: 225W 225W Door opening: Maximum Door Area: Maximum Door Weight: 235kg* 200kg* Door must be well balanced and able to be operated by hand, as per warranty conditions and AS/NZS 4505:2012 Minimum headroom 57mm...
ATS Series Installation Manual 12. Setting Limits 12.1 Set the Limit Positions and adjust drive speed: S E T T I N G L I M I T S CAUTION! Limit setup is not available when When setting the Close limit, ensure the position running on battery backup is when the door makes rst contact with the ground.
ATS Series Installation Manual 12. Setting Limits NOTE: If unhappy with the speed or travel limit setting, restart this procedure by resetting the door limit positions as per below first. 12.2 Clearing the Door Limit Positions C L E A R I N G T H E D O O R L I M I T P O S I T I O N S S T E P O N E S T E P T W O Remove controls cover...
ATS Series Installation Manual 13. Safety Testing 13.1 Test the Close Cycle CAUTION: Take care when completing a a. Press the OPEN button or transmitter button to open the door safety test. Failure to follow this warning (If the door starts closing, press the transmitter button to stop the can result in serious personal injury and/or door, then press transmitter again to open).
ATS Series Installation Manual 14. Auto-Close & Accessories 14.1 Auto-Close Auto-Close mode is a function that automatically closes the door after a pre-set time. Safety beams must be installed in order to run the Auto-Close function. There are two types of Auto-Close available: i.
ATS Series Installation Manual 14.2 Terminal Block Wired accessory items can be connected to the terminal block J4. Terminal connections from top down are as follows: a. +35V (Auxillary) b. AUX (Auxillary) c. SB (Safety Beam input, mandatory); d. GND (Common ground for accessories and Safety Beam); e.
ATS Series Installation Manual 15. Coding a Transmitter 3 . 0 C O D I N G A R E M O T E C O N T R O L NOTE: To code other transmitter functions, at STEP THREE 15.1 Storing the Transmitter Code C O D I N G R E M O T E F R O M T H E O P E N E R refer to below table of buttons to press.
ATS Series Installation Manual 15.3 Erasing All Transmitter Codes E R A S I N G A L L T R A N S M I T T E R C O D E S S T E P O N E S T E P T W O Remove controls cover Press...
ATS Series Installation Manual 16. Smart Phone Control The opener must be fitted with SAFETY BEAMS if: * the closing force at the bottom edge of the door exceeds 400N (40kg) and / or, * the opener has a smart device fitted to operate the door, when not in line-of-sight. Safety Beams detect any obstructions in the door/gate’s path and override automatic operation if one presents.
It is recommended to disengsgre the door with the door in the closed position. ATS Series Installation Manual DOOR 17. Opener Safety & Security 17.1 Your Door CAN NOT be used by the opener when: WARNING! When operating a. There is a locking device installed. manual release (while the door is open) b.
ATS Series Installation Manual 19. User Operating Controls Button Function 1. DOWN ARROW (Blue) Closes the door 2. DOWN ARROW LED (Blue) Illuminates when the door is closed and flashes when the door is obstructed on close or stopped. 3. STOP (Red) Stops the door 4.
ATS Series Installation Manual 20. Troubleshooting Symptom Possible cause Remedy The opener does not Garage door in poor condition e.g. Check the door’s operation work from the transmitter springs may be broken The opener does not have power Plug a device of similar voltage (e.g. a hairdryer) into the power point and check that it is OK The battery in the transmitter is flat Replace the battery...
Page 22
ATS Series Installation Manual 20. Troubleshooting Main Light = Service / Warning Indicator: Requirements for a service and user warnings are indicated after operation by the main light repeatably flashing OFF a number of times followed by a pause. When the alert is first triggered the beeper will also sound The below table identifys the issues and remedies.
ATS Series Installation Manual 21. After Installation Care 21.1 Service Checklist Preventative servicing of your garage door and opener, is WARNING! Failure to maintain your just as important as servicing your car. Much like the engine garage door voids the warranty on your of your car, your garage door is made up of numerous garage door opener.
When batteries reach the end of their usual life in accordance with Australian Battery Recycling Initiative please follow the next simple steps for protecting the environment. Refer to the Automatic Technology website for information on where to recycle batteries in Australia.
ATS Series Installation Manual 22. Appendix A - Status Indication during Operating Mode. LEDs Light Status Indicates BLUE GREEN YELLOW PURPLE DOOR OPEN AND CLOSED LEDS solid Open rapid Open with Autoclose timer running flashing flashing Opening / Obstructed on Open solid Closed flashing...
ATS Series Installation Manual B - Adjustment Mode Instructions A D J U S T M E N T M O D E I N S T R U C T I O N S S T E P O N E Remove controls cover Press till gear LED...
ATS Series Installation Manual A D J U S T I N G F O R C E M A R G I N S C - Adjusting Force Margins S T E P O N E The Safety Obstruction Force is calculated automatically during setup.
ATS Series Installation Manual F - Setting Limits via Transmitter S E T T I N G L I M I T S V I A T R A N S M I T T E R The SPEED setting on the opener CAN NOT be adjusted when setting limits via the transmitter.
Need help?
Do you have a question about the TEMPO ATS-2V3 and is the answer not in the manual?
Questions and answers