Technical Specifications For Five Port Outdoor Unit - Seabreeze MZ18H424ZMO Installation Manual

Mini-split dual / triple / quad zone / five port
Table of Contents

Advertisement

Technical Specifications for FIVE PORT Outdoor Unit

Model Number
Rated Voltage & Frequency and Phase
Min. - Max. Operating Voltage
Rated Input Current of the Power Conversion Equipment
Min. Circuit Ampacity (A)
Circuit Breaker Size (A)
Working Temperature Range (° F)
Low Ambient Cooling Function
Sound Power Level dB(A)
Resistance Class
Cooling
Heating @
47 ° F
Heating @
5 ° F
Fan Motor
Outdoor Fan
Max. Air Flow Volume of Outdoor Unit (CFM)
Compressor
Condenser
Chassis Electrical Heater Power Input (W)
Unit Dimensions (W x D x H) (in)
Dimensions &
Packing Dimensions (W x D x H) (in)
Weight
Connection
(between outdoor and indoor unit) (ft)
(between indoor and indoor unit) (ft)
Charge over Design Length on 1/4" liquid pipe [*4]
Wiring (Outdoor unit to Power Disconnect)
*1. 24,000 / 30,000 / 36,000 BTU indoor units use a 3/8" to 1/4" adapter joint that is included with the unit.
*2. 12,000 / 18,000 BTU indoor units use a 1/2" to 3/8" adapter joint that are included with the unit.
*3. 6,000 / 9,000 indoor units use a 3/8" to 1/2" adapter joint that is included with the unit.
24,000 / 30,000 / 36,000 BTU indoor units use a 5/8" to 1/2" adapter joint that is included with the unit.
*4. When the total length of liquid line is over 123 ft, the additional refrigerant charge is required.
NOTE: Outdoor unit must connect to a minimum of TWO indoor units.
950-0289revB
Capacity Invert Range (Btu/h)
Cooling Power Input (W)
Cooling Current Input (A)
EER (Btu/h/W)
SEER
Capacity Invert Range (Btu/h)
Heating Power Input (W)
Heating Current Input (A)
COP (W/W)
HSPF4
HSPF5
Rated Capacity (Btu/h)
COP (W/W)
Fan Type
Fan Motor Type / Model
Motor Insulation Class
Input (W)
Fan Speed (RPM)
Fan Blade Diameter / Height (in)
Model
TYPE
Brand
Capacity (Btu/h)
Input (W)
Crankcase Heater Input (W)
Oil Type / Charge Volume (oz.)
Overload Protector
Number of Rows
Fin Pitch (in)
Fin Type
Coil Length x Height x Width (in)
Number of circuits
Defrosting Method
Net / Gross Weight (lb)
Flare Liquid line
Flare Suction line
Service Port Fitting
Max. drive IDU Number
High Pressure (psi)
Low Pressure (psi)
Design Length (ft)
Max Line Set Vertical Height
Max Line Set Vertical Height
Max Line Set Length (ft)
Max Line Set Length (ft)
(oz. / ft)
Refrigerant / Charge
Wiring (Indoor to Outdoor)
Cooling: -13 to 122; Heating: -13 to 86
38.58 x 24.8 x 1.73 + 38.58 x 24.8 x 1.73
Five of 1/4"- 6K, 9K, 12K, 18K [*1]
115 (for the farthest indoor unit)
- 27 -
246-0603 MZ48H424ZMO
208-230V / 60Hz / 1PH
187 - 253 VAC
26
40
60
Yes
64
IPX4
48000 (19000~50000)
3,840
16.8
12.5
21
48000 (12500~52000)
3,910
17.1
3.6
11.5
8.8
27000
1.65
Axial-flow
DC Motor / ZKFN-85-8-22-5
E
126
900/850/800/750
21.81 / 5.83 x 2
4,500
ATQ360D1UMU
Rotary
GMCC
38216
3,040
27
ESTER OIL VG74 / 47.34
/
2
0.047
Hydrophilic Aluminum
10
Automatic Defrosting
150
37.48 x 16.34 x 52.48
43.11 x 19.49 x 57.48
225.53 / 256.62
Three of 3/8" - 6K, 9K Btu [*2]
Two of 1/2" - 12K, 18K Btu [*3]
1/2" - 20 UNF
5
550
340
123 (total) [*4]
49.2
32.8
262 (total)
0.161
R410A / 162 oz.
4C- 16 AWG
3C- 6 AWG
July 22, 2022