The following macro script operators are available.
Operator Character
&
|
!

Table 23: Macros Operator Characters

Outputs > Macros >

Scene

This menu allows you to program the scene for each macro.
A maximum of 8 different scenes can be configured. Macro
scenes can be up to 16 characters long.
Use the [] and [] keys to scroll cursor left and right.
Use the [0] – [9] keys or the [] and [] keys to scroll
characters, then press [OK] to save. Press [OFF] to clear
text from the current cursor position.
Only the following characters are supported when
constructing macro scenes.
Script Character
O
D
A
P
Q
Z
M
C

Table 24: Macros Scene Characters

The following macro scene operators are available.
Operator Character
&
|
!

Table 25: Macro Scene Operator Characters

Outputs > Output Testing >
External Siren Test
Internal Siren Test
Strobe Test
Fire Siren Test
Bosch Security Systems 10/22 BLCC615R
Operator Meaning
And
Or
Inverted Function
MENU 4-8-2
Character Represents
Output
Door
Area
Part 1
Part 2
Zone Bypass
Macro (TBA)
Countdown
Operator Meaning
And
Or
Inverted Function
MENU 4-9-0
MENU 4-9-1
MENU 4-9-2
MENU 4-9-3
Co mms Programm ing
Comms > Commands >
Reserved
Start Direct Link
Comms > Commands >

Register Customer

This menu is used to enter the customer registration
number into the control panel. This unique 11 digit
number is generated by the system owner when they
create an account on MyAlarm web site.
This is required for panels using the MyAlarm iFob Control
App. See the MyAlarm website for more information at
www.myalarm.com.au
Comms > Commands >

Register Installer

This menu is used to enter the installer registration
number into the control panel. This unique 11 digit
number is generated by the installer when they create an
installer account on the MyAlarm web site.
This number should be entered into all panels installed by
the installer allowing them to view all of their panels via
the MyAlarm web site.
Comms > Remote Access >

RAS Security PIN

Use keys [0] - [9] to program RAS Security PIN + [OK] to
save.
Comms > Remote Access >

Log Threshold

Enter 0 - 9 to program log threshold + [OK] to save.
Comms > Remote Access >

User RAS PIN