Possible
Problem/Report
Cause
No Water
Water
Dispensing
Pressure
Regulator
Check Tap
HMI Control
No Sparkling
No CO2
Water
pressure
Carbonator
Tank Not
Filling
Water
isolated
from
machine
Poor Quality
Incorrect
Carbonation
CO2
Pressure
Air in
Carbonator
Tank
Residue in
Carbonator
Tank
Warm Drinks
Insufficient
cooling air
flow through
the
fridge.
Compressor
not running
Fridge
failure (See
fault codes)
Suggested Action
Check water flow through the regulator.
Replace if necessary.
Check fault codes.
Check CO2 bottle, regulator and non-return valve. Supply pressure
should be 58 psi (4bar), replace as necessary.
Check carbonator probe for possible short circuit to ground.
Check for pump timeout, cycle power off & on then purge
carbonator.
Check water inlet supply.
Check CO2 bottle, regulator and non-return valve. Supply pressure
should be 58 psi (4bar), replace as necessary.
Visit to view steps for purging tank.
After prolonged use, a surface film can develop within the
carbonator tank. Refer to cleaning and sanitising instructions.
Check that the condenser is not blocked.
Check supply to cooling fans (230V AC).
If supply present replace fans.
If supply not present move on to the compressor. The supply to the
fans and the compressor are linked.
Check supply to compressor (230V AC).
Check NTC probe is not faulty
Check for system over heat. Allow the unit to cool and check for
airflow obstructions. Once the unit has cooled the fridge system will
restart. If the problem persists contact technical support.
If compressor & fan are running and there is no cooling contact
technical support.