Dimensions
The CAD data of the products with a
Low pressure type M Package (Terminal direction : DIP terminal, Pressure inlet hole length : 5 mm
Pressure
inlet hole
14.0
0.551
P/N,Lot
1B61
70124
JAPAN
Atmospheric
pressure inlet hole
Low pressure type L Package (Terminal direction : DIP terminal, Pressure inlet hole length : 13.5 mm
Pressure
inlet hole
14.0
0.551
P/N,Lot
1B61
70124
JAPAN
Atmospheric
pressure inlet hole
Low pressure type P Package (Terminal direction : DIP terminal, Pressure inlet hole length : 15.6 mm
Pressure
inlet hole
Atmospheric
pressure inlet hole
14.0
0.551
P/N , Lot
1B63
120215
JAPAN
0.25
0.010
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
mark can be downloaded from: http://industrial.panasonic.com/
P2.54×3=7.62
P0.100×3=0.300
Recommended PC board pattern
2.54
0.100
10.4
0.409
f 3.0
f 0.118
0.76
0.030
NU
V
Gnd
V
cc
out
NU
NU
NU
NU
P2.54×3=7.62
P0.100×3=0.300
Recommended PC board pattern
2.54
0.100
10.4
0.409
f5.45
f0.215
0.76
0.030
NU
V
Gnd
V
cc
out
NU
NU
NU
NU
P2.54 × 3=7.62
Recommended PC board pattern
×
P0.100
3=0.300
2.54
0.100
10.4
0.409
f5.45
f0.215
f3.00
f0.118
0.76
0.030
NU
V
Gnd
V
cc
out
NU
NU
NU
NU
Pressure Sensor/PS-A (ADP5)
(BOTTOM VIEW)
P2.54×3=7.62
P0.100×3=0.300
2.54
0.100
Terminal No.
Name
1
NU (Not usable)
2
Vcc (Power supply [+])
3
GND (Ground)
4
Vout (Output)
(BOTTOM VIEW)
P2.54×3=7.62
P0.100×3=0.300
2.54
0.100
Terminal No.
Name
1
NU (Not usable)
2
Vcc (Power supply [+])
3
GND (Ground)
4
Vout (Output)
(BOTTOM VIEW)
P2.54 × 3=7.62
×
P0.100
3=0.300
2.54
0.100
Terminal No.
Name
1
NU (Not usable)
2
Vcc (Power supply [+])
3
GND (Ground)
4
Vout (Output)
0.197
inch) ADP51B61
Terminal connection
diagram
8
7 6
5
1
2 3
4
0.01 μF
1.0 μF
unit : mm
inch
General tolerance : ±0.3
±0.012
Terminal No.
Name
5
NU (Not usable)
6
NU (Not usable)
7
NU (Not usable)
8
NU (Not usable)
0.531
inch) ADP51B62
Terminal connection
diagram
8
7 6
5
1
2 3
4
0.01 μF
1.0 μF
unit : mm
inch
General tolerance : ±0.3
±0.012
Terminal No.
Name
5
NU (Not usable)
6
NU (Not usable)
7
NU (Not usable)
8
NU (Not usable)
0.614
inch) ADP51B63
Terminal connection
diagram
8 7 6 5
1 2 3 4
0.01 μF
1.0 μF
unit : mm
inch
General tolerance : ±0.3
±0.012
Terminal No.
Name
5
NU (Not usable)
6
NU (Not usable)
7
NU (Not usable)
8
NU (Not usable)
01
Feb. 2019

Advertisement

Table of Contents
loading

Table of Contents