FOR 115 V., TIE LUGS AND 11 TOGETHER. YELLOW LEAD ON LUG 12. PUT HEAVY YELLOW LEAD ON LUG VARISTOR. BALLY PART NO. E·713-1, VARISTOR, BALLY PART NO. E·713, LOCATED IN CABINET, MUST BE USED LOCATED IN CABINET, MUST BE USED FOR OPERATION AT 220 V.
II. G E N ERAL GAM E O P ERATION Place ball into playfield by outhole. Coin game. Coin should be rejected . Plug in line cord . Move power ON-O FF master switch at bottom right front corner of cabinet to 'ON' position . The game wi" play a power-up tune to announce game-readiness .
III. BOOKKEEPING FUNCTIONS The game is designed to help the operator perform certain accounting functions. The game can display the number of total plays and replays (free games). It can display the number of coins dropped down each coin chute. T he bookkeeping functions are displayed on all player score displays simultaneously.
Page 8
IV. FEATURE OPERATION SCORING & BONUS SCORE FEATU RE: A bonus score of 1000 to 29,000 points may be scored. The game starts with a bonus score of 1000 points. The bonus score advances one step at a time each time the ball rolls over the top rollover button, rolls over lit right or lit left alley rollover buttons (see F below), hits the center target (see below), rolls over the midfield rollover button or goes through either right or left...
Page 9
D. SPECIAL: REPLAY IX-BALL/NOVELT Y MODES: Switch #31 & #32 g ive the operator flexibility to award a Replay, Extra Bal l or score (Novelty) when a Special is scored , (outlanes and Drop Targets) . The fol l owing chart explains the se tting s.
V. GAME ADJUSTMENTS A. ,Playfield Panel Post Adjustments: Easier entry will decrease playing time and scoring (conservative). Harder entry will increase playing time and scoring (liberal). Credits/Coin Same as Coin Chute #1 Settings 1/1 Coin 211 Coin 3/1 Coin 4/1 Coin 5/1 Coin 6/1 Coin 7/1 Coin...
C. Front Door Game Adjustments: High Score Feature Adjustments: The game is designed to award an extra ball (option) or a free game at each of three score levels. The recommended levels are on the score card in the game. Any level from 10,000 to 990,000 can be set, as desired.
Page 17
#1120-E POWER PLAY RECOMMENDED SETTINGS 3-B ALL 5-BALL SW.230FF T humper Bumpers SW.230N SW.150FF Rollover Buttons Sw.150N SW.220FF Drop Target Reset SW.220FF SW.140FF Drop Target X-Ball SW.140FF SW.290FF Outlane SW.290FF Sw.300N Sw.300N T he following chart gives recommendations for three typical types of operation. 3-BALL 5-BALL REPL AY...
VIII. ROUTINE MAINTENANCE ON LOCATION: Self-Test routines are written into the game design. They are particularly useful for routine maintenance. The tests are described below. The first test is automatic and occurs on power-up. This test causes the MPU module A4 to examine itself for failures. Seven flashes of an LED indicates proper operation: The second series of self-diagnostic tests causes the MPU to 'exercise' each of the other modules in such a way as to make their faults, if any, obvious.
Page 19
SELF DIAGNOSTIC TEST FIGURE IV RO()TINE MAINTENANCE CHECK REFER TO 'TROUBLE SHOOTING ON L OCATION' CORRECT FAULT POWER-UP: TURN OFF POWER TURN ON POWER SEE SYMPTOM PAGE 15 LED ON MODULE A 4 FLASHES PRESS SELF-TEST BUTTON ON INSIDE OF FRONT DOOR TO ENTER LAMP DRIVER MODULE TEST SEE SYMPTOM PAGE 15...
Page 20
Gam e does not p l ay power-u p t u n e w h e n p ower is turne d on. G e ne ral 1 A) SYMPTOM: I l l u m i nation is p resent. Tu rn power O FF.
Page 21
If g a m e is correct, it is now read y to p l ay.* If g ame is not co rrect , refer to M od ul e Repl acem ent p roced ure. (See Parts li st. ) SYMPTOM: One or several d ispl a ys a l ways off.
Page 22
GAM E #1120-E P OWER PLAY SOLENOID IDENTIFICATION TABLE S E LF- S E LF- T EST SOL ENOID ID ENTIFI C ATI ON T EST SO LENOID IDENTIFI C AT I ON RIGHT THU MPER B U MPER OU THOL E KIC K ER BonOM T HU MPER B U MPER KNO C K ER L E FT DROP TARG E T...
1333 W. Seminary Drive , Ft . Worth, Texas 76115). Wildcat #125 is a combination c leaner and polish . Bally has tried and tested this product and found it to be very effective . If Wildcat # 125 is not available , Bally suggests you ask your Distributor to order it . Inspect and hand polish the bal l i n a clean cloth .
Page 27
A4 : M P U M O D U L E COM PONENT PARTS LIST R E F E R E N C E B A L LY I T E M D E S I G N AT I O N PA R T D E SC R I PT I O N M P U Module Complete.
Page 28
Q5D QSI QSZ. QS3 J"l. TYPICf'.-L 2.4 PLKE'� AS : LAM P DRIVER MODULE COMPONENT PA RTS LIST REFERENCE BALLY PA RT ITEM DESIGNATION DESCRIPTION AS- 25 1 8- 1 4 Lamp D river M od u l e , Com p l ete...
Page 29
AS-2S 1 8-21 D I S P LAY D R I V E R M O D U LE A1 : 1> I SPLAY DRIVER M O DULE COMPONENT PARTS LIST REFERENCE BALLY DESIG NATI O N PART # ITEM QTY.
Page 31
A3: SOL ENOID DRIV ER / VOLTA G E R E GULATOR MODUL E COMPONENT PARTS LIST REFERENCE BALLY ITEM DESI GNATION PART DESCRIPTION Solenoid D river/ Voltage AS-251 8-22 Reg u l ator M od u l e , Complete...