(e.g. texts, images, photos) including extracts in any type of media (such as print, CD-ROM, internet) is only permitted with Schrack Seconet explicit written consent. For printing errors and obvious errors no liability is accepted. For enquiries and orders, please indicate article numbers.
Page 5
(e.g. communal collection points or in shops). Proper disposal of the devices will relieve the burden on the environment. For more detailed information please contact your waste disposal center. B-HB-0133EN Operating panel Integral MAP | User manual ...
The product-specific training of staff members must be carried out by Schrack Seconet or by skilled personnel who have been specifically authorised to carry out this duty by Schrack Seconet.
Overview Overview The Integral MAP indication and operating panel is used for operating and indication of the Schrack Seconet Integral fire alarm control panels. From this panel, it is possible to send commands to the system, as well as to display the system status of all devices.
Overview | Acoustic signals Acoustic signals | Acoustic signals Every Integral MAP uses five different acoustic modes: Alarm signal 100 ms, 3 kHz – 100 ms, silence Fault signal 800 Hz continuous tone Signal of acknowledgement 140 ms, 800 Hz – 140 ms, silence time Signal of intervention period 4 ×...
Page 9
LED remain lit up. Any additional alarm or fault message will trigger the alarm and fault signal tones again. Acknowledgement and intervention signal tones cannot be reset. B-HB-0133EN Operating panel Integral MAP | User manual ...
Display in idle mode Schrack Seconet 29.01.2020 INTEGRAL 0000 0000 0000 0000 0000 In an idle mode (standard indication), the display shows product and customer informa- tion. The list counters are set to 0. Operating panel Integral MAP | User manual B-HB-0133EN...
Page 11
Display with site information Pressing the button Site Info displays site information. Site information for a detector SITE INFO ZONE 103/1 CUSTOMER TEXT FOR DETECTOR 103/1 E.G. BUILDING, ROOM 0000 0000 0001 0000 0001 B-HB-0133EN Operating panel Integral MAP | User manual ...
Page 12
1 is entered. Further Information: Chapter Operation release (authorisation levels), Page 22 3.3.3.4 Menu Pressing the button Menu opens the menu for additional options. Available functions depend on programming and the authorisation level. Further Information: Chapter Menu functions, Page 26 Operating panel Integral MAP | User manual B-HB-0133EN...
(power failure) or a battery fault (battery defective) is detected. Further Information: Chapter Fault messages, Page 20 The Disablements LED lights up, if at least one system element is disabled. B-HB-0133EN Operating panel Integral MAP | User manual ...
(no transmission system is activated, or the system is faulty or dis- abled). Pressing the button Disable/Enable turns the transmission equipment’s controller on/ off alternately. The Disable/Enable LED next to the button lights up, if the transmis- sion equipment is disabled. Operating panel Integral MAP | User manual B-HB-0133EN...
The LED next to the button and the LED lights up, if the alarm sys- tems are disabled. The sirens are not activated, even not in case of an occurring alarm. B-HB-0133EN Operating panel Integral MAP | User manual ...
(night/absence programme), the LED is off. Various functions can be programmed for delay layers, such as automatic or time-de- pendent activation/deactivation or function switching. The delay layer must be activated for the intervention/intervention mode. Operating panel Integral MAP | User manual B-HB-0133EN...
LED remain lit up. Any additional alarm or fault message will trigger the alarm and fault signal tones again. Acknowledgement and intervention signal tones cannot be reset. B-HB-0133EN Operating panel Integral MAP | User manual ...
The intervention function is only permissible for detector zones with smoke detectors. Alarm messages generated by the heat and flame detector as well as the manual call point trigger the transmission system without delay and are immediately forwarded to the emergency services. Operating panel Integral MAP | User manual B-HB-0133EN...
In list view or element view, additional information can be called up for each element, e.g. detector zone, detector number, date and time or in case of an event, e.g. alarm, fault, disablement or actuation. B-HB-0133EN Operating panel Integral MAP | User manual ...
If the reason for failure is known (e.g. power failure, reconstruction work), disable the faulty device if necessary. Call the service department/customer service (necessary in- formation: equipment type and number, customer number, messages, error codes). Operating panel Integral MAP | User manual B-HB-0133EN...
Additional external signalling systems by pressing the Input button. All other types of element, which could not be selected by using one of the other buttons listed above (e.g. Printer, Battery etc.) by pressing the Other Elements button. B-HB-0133EN Operating panel Integral MAP | User manual ...
Note or save the authorisation code at a safe place and protected it from unauthorised access. Pressing the button Access Code Enter the access code of a higher authorisation level using the numerical buttons of the keypad Operating panel Integral MAP | User manual B-HB-0133EN...
Using the scroll buttons E/F to scroll through all the entries in the list. Con- firm with the enter button D. NOTE Using other commands it is possible to disable detectors with time limits. B-HB-0133EN Operating panel Integral MAP | User manual ...
Enter the the last (highest) number of the range using the numerical buttons of the keypad Confirm with the enter button D. The selected detector zones can be operated together with the desired command ( – Operating panel Integral MAP | User manual B-HB-0133EN...
Pressing the button Menu opens the menu for additional options. Using the scroll buttons E/F to select the entry ALARMCOUNTER. Pressing the Enter key D shows the number of alarms that have occurred so far. B-HB-0133EN Operating panel Integral MAP | User manual ...
E/F to scroll through all the entries in the list. NOTE In some countries (e.g. Austria) automatic switching from night time to day- time operating mode is not allowed. Only the switchover time from daytime to night time operation is displayed. Operating panel Integral MAP | User manual B-HB-0133EN...
Using the scroll buttons E/F to select the log printer for repeating a print from the list. Confirm with the enter button D. Using the scroll buttons E/F to scroll through the list of available lists EVENTLOG,TRACELOG, FAULTS, DISABLEMENTS. Confirm with the enter button D. B-HB-0133EN Operating panel Integral MAP | User manual ...
Need help?
Do you have a question about the Integral MAP and is the answer not in the manual?
Questions and answers