Installation Requirements
This shower valve must be installed in
compliance with currentwaterregulations.
If you have any doubts about the water
regulation requirements contact yourlocal
water services provider or usethe services
of a professionalplumber.
This shower valveis suitable for use with
the following water supplysystems.
•Gravity Fed Hot and Cold
(pressureBalanced)
•Gravity Fed Hot and Mains Cold
(differential pressure –seeSpecification
section on page5.
•Instantaneous Water Heater
(combination boiler)
• Unvented System
• Pumped System
Gravity Fed Hot and Cold
Cold mainssupply
08
valve with a gravity fed system, there must
be a minimum head (vertical distance)
from the underside of the cold water
storage tank to the showerhead positionof
at least 2metres.
Note: Pumped system (with Essex flange)
If you install this shower valve to a pumped
gravity fed system where the minimum
head (vertical distance) fromthe underside
of the cold water storagetankto the top of
the hot water cylinder is less than 1 metre
we recommend an Essex flange is used as
shown on page10.
Flushing Pipework
shower valve (see Installation on pages13-
20), supply pipework must be flushed to
clear debris before connecting the shower
valve. Debris will reduce the performance
and life of theshower.
Gravity Fed Hot and MainsCold
2m
min
Important: If you install this shower
Important: Before connecting the
Cold mainssupply
2mmin