RX230 Group, RX231 Group
VCC/VBATT
State
(1)
(initial state)
Vcc = On (active)
Vbatt = On
(2)
Vcc = On Off,
Vbatt = On  On
(switch to battery)
(3)
Vcc = Off,
Vbatt = On
(battery active)
Vcc = Off  On,
(4)
(switch to VCC)
Vbatt = On
(5)
Vcc = On
(VCC active)
Vbatt = On
(6)
Vcc = On
Vbatt = On  Off
(battery depleted)
R01AN4831EJ0100 Rev.1.00
Aug.20.19
Initial Settings and Usage Procedure of RTC Battery Backup Function
Table 1.1 Operating Conditions
VBATT Pin
Voltage
Voltage Drop
Monitor 0
Detection
Reset
Interrupt
(Vdet0)
(Vdetvbt)
No
Enable
generated
Generated
No
On hold
No
Released
No
Not
Enable
generated
Not
Generated
generated
RTC
Data Saved
LCD
Count
(RAM, Time
Operation
Display
Information)
Operating
Yes
No
Operating
Turn off
Saved
Operating
No
Saved
(No if
VBATT
below
1.8V)
Operating
Turn on
Saved
Operating
Yes
Saved
Operating
Yes
Saved
RTC
Initialization
Input Capture
Yes
Enable
No
Enable
No
Enable
(inputted)
No
Enable
(Yes if VBATT
below 1.8V
detected)
No
Enable
No
Enable
Page 5 of 23