Eeprom-Failure - HARTING Ha-VIS RFID RF-R400 System Manual

Rfid reader
Table of Contents

Advertisement

Ha-VIS RFID RF-R400 – System Manual
112
Hex-value
Transponder Status
0x05
Wrong transponder type:
• This command is not applicable at the transponder:
• A special command is not applicable to the transponder.
0x08
Authent error:
• If access password is wrong
Hex-value
Parameter Status
0x10

EEPROM-Failure:

• The EEPROM of the reader is not able to be written on.
• Before writing onto the EEPROM a faulty checksum of parameters has been detected.
0x11
Parameter-Range-Error:
• The value range of the parameters was exceeded.
0x13
Login-Request:
• Configuration access without having logged in to the reader before.
0x14
Login-Error:
• Login attempt with wrong password.
0x15
Read Protect:
• The configuration block is reserved for future use.
0x16
Write Protect:
• The configuration block is reserved for future use.
0x17
Firmware activation required:
The firmware must be activated first using Ha-VIS RFID Config demo program and the
command "Set Firmware Upgrade". The update code must be ordered by HARTING
Technology Group.
1. Read the Device-ID using the command [0x66] Firmware version (Mode 0x80)
2. Send the Device-ID and the serial number of the reader to HARTING Technology Group
3. Write the upgrade code into the reader using the command [0x5F] Set Firmware Update
0x18
Wrong Firmware:
• Mismatch between RFC Firmware and Hardware
Hex-value
Interface Status
0x80
Unknown Command:
• The reader does not support the selected function.
0x81
Length-Error:
• The selected function has the wrong number of parameters.
0x82
Command not available:
• A Host command was sent to the reader in the Buffered Read Mode.
• A Buffered Read Mode protocol was sent to the reader in the standard mode.
• The command with more bit does not correspond with the last command.
0x83
RF communication error:
• This error indicates that there is an error in communication between the transponder and
the reader. Reason for this can be:
• Timeout for transponder communication. "Transponder-Response-Time" in 7.2. CFG1:
Interface and Mode is too short.
• The collision handling algorithm was not continued until no collision is detected, reasons
for the break.
HARTING IT Software Development GmbH & Co. KG

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Ha-VIS RFID RF-R400 and is the answer not in the manual?

Questions and answers

HUGUETTE TOUSSAINT
March 14, 2025

to have ip address per defaul to connect to a harting ha-vis rfid rf-4àà

1 comments:
Mr. Anderson
March 14, 2025

The default IP address for the HARTING Ha-VIS RFID RF-R400 is 192.168.10.10.

This answer is automatically generated

Related Products for HARTING Ha-VIS RFID RF-R400

This manual is also suitable for:

20 91 107 1101