Fired Up Corporation BEF0001 Safety Manual

Bio-ethanol fire, inset fires, free standing, stoves, fireboxes
Hide thumbs Also See for BEF0001:

Advertisement

Quick Links

B I O - E T H A N O L F I R E
S A F E T Y M A N U A L F O R :
INSET FIRES
FREE STANDING
STOVES
FIREBOXES

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BEF0001 and is the answer not in the manual?

Questions and answers

Summary of Contents for Fired Up Corporation BEF0001

  • Page 1 B I O - E T H A N O L F I R E S A F E T Y M A N U A L F O R : INSET FIRES FREE STANDING STOVES FIREBOXES...
  • Page 2: Table Of Contents

    Read ALL the instructions before use. These instructions are for your safety. Please read through them thoroughly before use and retain for future reference. Failure to follow them could cause injury and/or property damage. Note: This manual applies for a number of different products.
  • Page 3: Introduction

    INTRODUCTION WARNING: FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN FIRE, PROPERTY DAMAGE, SERIOUS INJURY OR DEATH. The contents of this manual are intended to provide simple and informative instructions on how to safely install and use your bio-ethanol fire. Before assembling the product, please take the time to read this manual thoroughly.
  • Page 4: Important Safety Information

    BIO ETHANOL FIRES Burner Min Room Approx. Model No. * Weight (kg) Size (L) Vol.(m3) Burn time (hrs BEF0001 BEF0007 BEF0008 BEF0010 BEF0011 BEF0012 21.6 BEF0013 BEF0014 BEF0015 *Model numbers can be located on the label attached to the product...
  • Page 5: Section 02 - Important Safety Information

    IMPORTANT SAFETY INFORMATION Please take the time to familarise yourself with ALL the information contained within this section of the manual. Keep suitable Adhere to ALL instructions about extinguishing agent bio-ethanol fuel. ready. Fire danger / oxidising / Do not smoke when Harmful.
  • Page 6: Installation And Location

    • If anyone in the vicinity of the fire experiences sickness or headaches, extinguish the fire immediately and open all doors and windows. • Once lit, DO NOT pour bio-ethanol liquid into the fire. • DO NOT leave a lit fire unattended at any time. •...
  • Page 7: Adding Fuel

    cookware retailers. • DO NOT locate the fire in a location where it could be knocked or tipped over. • DO NOT use this bio-ethanol fire on anything other than a suitably strong, stable, flat, level, permanent, heat and scratch resistant, low surface in a well ventilated area.
  • Page 8: During Use

    • DO NOT light the fire in a room which already contains a burning fire. • To light the bio-ethanol liquid fuel use a long stem lighter at arms length at a minimum distance of 140mm from the handle of the lighter to the opening of the bio-ethanol burner.
  • Page 9: Caring For Your Product

    • The fuel tray MUST be completely covered by the extinguishing plate. • DO NOT handle or return to the product until the flame has been completely extinguished. • Once the fire is completely cool you may return to the product. IN AN EMERGENCY: •...
  • Page 10 MINIMUM DISTANCES TO COMBUSTIBLE MATERIALS 69mm Inset Fires 32mm 32mm 800mm Free Standing 200mm 200mm 200mm 300mm 100mm Stoves 200mm 200mm 200mm 100mm 100mm Fireboxes 200mm...
  • Page 11 TOOLS REQUIRED FOR INSTALLATION A crosshead screwdriver An electric drill A 6mm diameter masonry bit A 2mm diameter drill bit A pencil PARTS SUPPLIED Inset Fire 1 x Cable 1 x Hook 1 x Trim 1 x Fire Body 1 x Bio-Ethanol 1 x Flame 1 x Filler Burner...
  • Page 12: Installation

    IMPORTANT: ON ALL MODELS PLEASE ENSURE THE BURNER RESERVIOR IS FACING THE FRONT OF THE FIREPLACE REAR ......
  • Page 13 FITTING AN INSET FIRE Installing the fire where a stone or marble back panel is used 1. For solid walls, drill 2. Insert wall plug the 2 holes approxi- into wall, then mately 35mm deep tighten the hook using a 6mm screwthread into diameter drill bit.
  • Page 14 FITTING A FIREBOX This fire is suitable to fit into surrounds with a minimum opening (A & B) 420mm 570mm Fit the neoprene strips behind the trim to adhere to the back panel CONFORMITY WITH DIRECTIVES Conforms with relevant European Directives...
  • Page 16: Guarantee

    You are strongly advised to read this manual carefully in its entirety and to retain it for future reference. This product guarantee does not affect your statutory rights. CUSTOMER HELPLINE +44 (0) 3300 882 069 customer.support@firedupcorporation.com Fired Up Corporation Ltd Fired Up Buildings HD1 3LF, UK www.firedupcorporation.com Fired Up Corporation (Ireland) Ltd...

Table of Contents