EIC Solutions AAC-145A-4XT-M34 Series Installation And Operation Manual

EIC Solutions AAC-145A-4XT-M34 Series Installation And Operation Manual

Thermoelectric air conditioner

Advertisement

Quick Links

EIC SOLUTIONS, INC
.
Thermoelectric Air conditioner installation and operation manual
FOR 1500 Btu MODEL #'S
AAC-145A-4XT-M34
AAC-145A-4XT-HC-M34
AAC-145A-4XT-M34-XXXXX
Cooling Solutions for
Mission-Critical Electronics
-800-497-4524
EIC SOLUTIONS, INC
215-443-5190
1
.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AAC-145A-4XT-M34 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for EIC Solutions AAC-145A-4XT-M34 Series

  • Page 1 EIC SOLUTIONS, INC Thermoelectric Air conditioner installation and operation manual FOR 1500 Btu MODEL #’S AAC-145A-4XT-M34 AAC-145A-4XT-HC-M34 AAC-145A-4XT-M34-XXXXX Cooling Solutions for Mission-Critical Electronics -800-497-4524 EIC SOLUTIONS, INC 215-443-5190...
  • Page 2: Table Of Contents

    3. OPERATION THERMOSTAT SET POINTS AND HEATING COOLING UNITS ............... MAINTENANCE ..................................4. SPECIFICATIONS STANDARD SPECIFICATIONS ............................................5. APPENDIX CUTOUT ........................................................EIC SOLUTIONS INC. 700 VETERANS WAY, SUITE 200 WARMINSTER, PA 18974 PHONE 1-215-443-5190 or 1-800-497-4524 FAX 215-443-9564 EMAIL info@eicsolutions.com VISIT US ON THE WEB AT www.eicsolutions.com.
  • Page 3: General Information

    Your EIC Solutions Thermoelectric Air Conditioner operates on this principle so there is no compressor and no expensive, ozone depleting CFC’s. EIC’s air conditioners use Thermoelectric “modules”...
  • Page 4: Installation

    If this orientation is the only possible configuration, contact the Engineering Dept. at EIC for a custom solution. Issues regarding access should be considered and minimum clearances must be maintained as outlined in Section 2.1 of this manual. -800-497-4524 EIC SOLUTIONS, INC 215-443-5190...
  • Page 5 FIGURE 2.1 -800-497-4524 EIC SOLUTIONS, INC 215-443-5190...
  • Page 6: Preparing The Enclosure

    5. Install the rest of the screws in the flange placing a nylon washer on each fastener and screw them into the tapped holes in the enclosure. Do not tighten them completely. 6. Remove the two starter screws and place a nylon washer on each and reinstall. 7. Tighten all screws. -800-497-4524 EIC SOLUTIONS, INC 215-443-5190...
  • Page 7: Apply Power

    The cold side fan always runs when the unit is powered on to circulate air within your enclosure thereby eliminating any “hot spots”. The hot side fan will only run when the air conditioner is cooling. -800-497-4524 EIC SOLUTIONS, INC 215-443-5190...
  • Page 8: Operation

    NEVER EXPOSE THE COLD SIDE OF THE AIR CONDITIONER (INSIDE THE ENCLOSURE) TO WATER. If you have any questions about any aspect of your EIC air conditioner, don’t hesitate to call us at the numbers listed below. -800-497-4524 EIC SOLUTIONS, INC 215-443-5190...
  • Page 9: Specifications

    Sound Level at 1 meter 62 dBA -4 to 140 °F Operating Temperature Range -20 to 60 °C -4 to 185 °F Storage Temperature Range -20 to 85 °C ±1.0 °F Cooling Thermostat Accuracy ±0.6 °C -800-497-4524 EIC SOLUTIONS, INC 215-443-5190...
  • Page 10 APPENDIX A Holes to be 8-32 Tap -800-497-4524 EIC SOLUTIONS, INC 215-443-5190...