Advertisement

DO NOT RETURN
TO STORE!
CALL US FIRST
855-888-3598
FOR SUPPORT
Model:
Serial:
Date Purchased:
P/N: 32082-04705-03
PORTABLE GENERATOR
Owner's Manual
GXS7100iRD
Model# 3222003 REV01
SAVE THIS MANUAL FOR FUTURE REFERENCE

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GXS7100iRD and is the answer not in the manual?

Questions and answers

Summary of Contents for iPower GXS7100iRD

  • Page 1 PORTABLE GENERATOR Owner’s Manual GXS7100iRD DO NOT RETURN TO STORE! CALL US FIRST 855-888-3598 FOR SUPPORT Model# 3222003 REV01 Model: Serial: Date Purchased: SAVE THIS MANUAL FOR FUTURE REFERENCE P/N: 32082-04705-03...
  • Page 2: Table Of Contents

    Table of Contents Introduction..........1 Low Idle Switch........23 Stopping the Engine......23 Safety............1 Low Oil Shutdown........24 General Safety Precautions....2 Do Not Overload Generator....24 Unpacking the Generator.......8 Changing Fuels........25 Parts Included........8 Parallel Operation.........25 Controls and Features......9 Set up and Operation......25 Control Panel Features......10 Maintenance And Storage....27 Remote Control Programming....12 Maintenance Schedule......27...
  • Page 3: Introduction

    Service at 855-888-3598, or which are known to the State of California to cause www.a-ipower.com for starting, operating and cancer and birth defects orother reproductive harm. servicing procedures. The owner is responsible for To minimize exposure, avoid breathing exhaust, and proper maintenance and safe use of the unit.
  • Page 4: General Safety Precautions

    Asphyxiation Electric Shock Fire Hazard Hazard Hazard Hot Surface. Explosion Moving Parts Do Not Touch the Surface. Hazard Hazard Burn Hazard Kickback Operator’s Manual GENERAL SAFETY PRECAUTIONS • Operate this product ONLY outside far away from windows, doors and vents to reduce the risk of Using a generator indoors CAN KILL YOU IN MINUTES.
  • Page 5 CORRECT USAGE Example location to reduce risk of carbon monoxide poisoning • ONLY use outside and downwind, far away from windows, doors and vents. • Direct exhaust away from occupied spaces. INCORRECT USAGE Do not operate in any of the following locations: •...
  • Page 6 Propane/LPG (Liquid Petroleum Gas) WARNING • Propane/LPG is highly flammable and explosive. Starter cord kickback (rapid retraction) • LPG is heavier than air and can settle in low places will pull hand and arm toward engine while dissipating. faster than you can let go which could •...
  • Page 7 • Store Fuel in a container approved for gasoline. DANGER • Store any containers containing gasoline or propane/LPG outdoor in a well-ventilated area, away from any combustibles or source of ignition. DANGER Gasoline, gasoline vapor and propane/LPG are highly flammable and explosive. Generator voltage could cause electrical Never use a gasoline container, gasoline tank, shock or burn will result in death or...
  • Page 8 WARNING WARNING Starter and other rotating parts could entangle hands, hair, clothing, or accessories. Keep away from rotating parts, failure to do so could result in Exhaust heat/gases could ignite combustibles, death or serious injury. structures or damage fuel tank causing a fire, •...
  • Page 9 • Shut off generator if: -Electrical output is lost. -Equipment sparks, smokes, or emits flames. -Unit vibrates excessively. WARNING Medical and Life Support Uses. • In case of emergency, call 911 immediately. • NEVER use this product to power life support devices or life support appliances.
  • Page 10: Unpacking The Generator

    UNPACKING THE GENERATOR • Open carton completly. Remove and verify carton content prior to assembly. Your generator ships with following items. • Call our customer service at 855-888-3598 with the unit model and serial number for any missing item. • Record model, serial number, and date of purchase on front cover of this munual for your own record.
  • Page 11: Controls And Features

    CONTROLS AND FEATURES 1 - Control Panel 6 - Maintenance Cover 2 - Telescopic Handle 7 - Support Leg 3 - Romote Holder 8 - Engine Oil Access Cover 4 - Fuel Cap 9 - Muffler/Spark Arrester 5 - Recoil Starter 10 - Wheel 11 - Propane Inlet Page 09...
  • Page 12: Control Panel Features

    CONTROL PANEL FEATURES 1. LED Data Center: See LED DATA CENTER section. 10. Grounding Terminal: To ground the generator. 2. Push-Button START/STOP: Push once to automati- 11. 120V AC, 20A Duplex, Single Phase, 60Hz Outlets cally start the engine. Push again to stop the engine. (5-20R): Each outlet is capable of carrying a maximum of 20 amps on a single outlet or a ombination of both 3.
  • Page 13 CONTROL PANEL FEATURES LED Data Center 4. Overload Rest Button With Indicator Light: The 1. LED Multi-Meter: Displays voltage,power,fuel level, indicator light is green when theinverter is running under frequency, and running time. rated load. The indicator light will turn to blinkingred or 2.
  • Page 14: Remote Control Programming

    REMOTE CONTROL PROGRAMMING Before the generator can be started , an initial start-up Press and hold the START button of the remote procedure must be performed so the generator and the control fob, the engine push button red light will remote control recognize each other.
  • Page 15: Specifications

    SPECIFICATIONS GXS7100iRD Model Number 3222003 Starting Watts 7100W-GAS / 6400W-Propane/LPG Running Watts 5700W-GAS / 5100W-Propane/LPG Rated AC Voltage 120/240V Rated DC Voltage Rated Frequency 60HZ Phase Single Grounding System (AC) Neutral Floating Engine Type Single Cylinder, 4-Stroke OHV Air Cooled...
  • Page 16: Co Watch-Guard

    CO WATCH-GUARD Carbon Monoxide (CO) Detection and Auto Shutoff System Your Generator is equipped with Carbon Monoxide (CO) WATCH-GUARD detect system for your protection and safety. This detecting and shutoff system monitors for the accumulation of poisonous CO gas around the generator produced by engine exhaust when the generator is running.
  • Page 17 The generator is shutoff automatically and the yellow light will blink for at least five minutes after shutoff. Call A-iPower Customer Service 855-888-3598 for repair. Do not use the generator until the sensor is working properly. The CO WATCH-GUARD must only be serviced by qualified technician to restore it to original settings.
  • Page 18: Add Engine Oil

    Add Engine Oil NOTICE We recommend using SAE 10W-30 APISJ oil for We consider the first 5 hours of run time to be the best performance. Other high-quality detergent oils break-in period for the unit. During the break in (APISJ or higher) are acceptable. Do not use special period stay at or below 50% of the running watt additives.
  • Page 19: Add Fuel: Gasoline

    Add Fuel: Gasoline WHEN ADDING GASOLINE • Only fill the gasoline tank outdoors in a DANGER well-ventilated area. • DO NOT overfill gasoline tank. Allow space for fuel expansion. • If gasoline spills, wipe spilled gasoline from the unit or wait until it evaporates before starting engine. Gasoline and gasoline vapor are highly flammable •...
  • Page 20 • Use only an approved LPG cylinder equipped with Propane/LPG is highly flammable and explosive. an OPD (overfilling prevention device) valve. Fire or explosion can cause severe burns or death. • DO NOT check for leaks with a lighted match or •...
  • Page 21: Fuel Sense

    3.5% for every 1000 feet (305 m) of elevation above sea level. High altitude may cause hard starting, increased fuel consumption and spark plug fouling. To operate at high altitudes A-iPower can provide a high altitude carburetor main jet. The alternative main jet and installation instructions can be obtained by contacting Customer Support.
  • Page 22: Operation

    OPERATION Surge suppressors come in single- or multi-outlet Generator Location styles. They’re designed to protect against virtually WARNING all short-duration voltage fluctuations. Make sure you review each warning in order to prevent fire hazard. Before Starting the Generator • Make certain the generator is on a flat, level surface Using a generator indoors CAN KILL YOU IN MINUTES.
  • Page 23: Select The Fuel Source (Gasoline)

    5a. Remote start when the Voltage Selector Switch in in the “120V” Turn and hold the REMOTE START switch for 5 position. seconds until the engine start. WARNING Only change the Voltage Selector Switch with the generator OFF. DO NOT switch the voltage while the generator is running or powering appliances.
  • Page 24: Connecting Electrical Loads

    2. Fully open the Propane/LPG cylinder knob. WARNING Starter cord kickback (rapid retraction) will pull hand and arm toward engine faster than you can let go which could cause broken bones, fractures, bruises, or sprains resulting in serious injury. When starting engine, pull cord slowly until resistance is felt and then pull rapidly to avoid 3.
  • Page 25: Low Idle Switch

    Low Idle Switch Stopping the Engine 1. Turn off and remove entire electrical loads. NOTICE Never start or stop the generator with electrical Always start the generator with LOW IDLE SWITCH devices plugged in or turned on. on OFF position. Allow the engine speed to stabilize Let the generator run at no-load for two minutes to before switching LOW IDLE Switch to ON position stabilize internal temperatures of the engine and...
  • Page 26: Low Oil Shutdown

    4. Turn cylinder valve to the OFF position. Do Not Overload Generator Overloading a generator in excess of its rated wattage capacity can result in damage to the generator and to connected electrical devices. To prolong the life of your generator and attached devices, follow these steps to add electrical load: 1.
  • Page 27: Parallel Operation

    Propane Cylinder Valve OR having an insuffi- cient remaining level of propane in the cylinder will immediately replace propane intake with gasoline intake. Parallel Operation (2 x GXS7100iRD Models) 1.Disconnect all electrical loads from the generator. WARNING Fire and electrocution hazard. Never connect or disconnect the parallel cord leads when a generator is running.
  • Page 28 WARNING If not spaced apart, the exhaust heat from one generator discolors or melt the plastic shell on other generator. 20” 5. Start one of the generators and wait until the engine speed to stabilize. 6. Start the second generator and wait until the engine speed to stabilize before connecting a load.
  • Page 29: Maintenance And Storage

    MAINTENANCE AND STORAGE MAINTENANCE SCHEDULE NOTE: Maintenance should be performed more frequently Regular Maintenance will improve the performance when generator is used in dusty areas. and extend the life of your generator. Follow When generator has exceeded the maximum figures maintenance schedule intervals whichever occurs specified in the table, maintenance should still be first according to use.
  • Page 30: Change Engine Oil

    Recommended Engine Oil Type CAUTION 1 0W-3 0 1. With the help of another person, place the generator 5 W-3 0 1 0W-4 0 on an elevated platform, such as a table or work bench. 5 W-3 0 Full Synthetic 2.
  • Page 31: Battery Replacement

    5. Apply a layer of engine lubricant on the filter CAUTION element and squeeze it out. Battery posts, terminals contain lead and lead 6. Reinstall the filter element into the air cleaner compounds. Wash hands after handling. unit. 7. Reinstall the air filter cover plate (C). 1.
  • Page 32: Valve Clearance

    in. (0.7-0.8 mm). To widen gap, if necessary, 2. Loosen the bolt (A) to remove the flange pressing carefully bend the ground (top) electrode. To plate (B) and the spark arrester(C). lessen gap, gently tap ground electrode on a hard 3.
  • Page 33: Long Term Storage

    Short Term Storage DRAINING THE FLOAT BOWL Fill the tank with fresh gasoline and add gasoline 1. Turn the starting dial switch to the OFF position. stabilizer. Drain the carburetor float bowl. 2. Remote the maintenance cover. 1 - Add a properly formulated FUEL STABILIZER to 3.
  • Page 34: Trouble Shooting

    TROUBLE SHOOTING PROBLEM POSSIBLE CAUSE SOLUTION Engine is running, 1. AC Circuit breaker is open. 1. Check AC load and reset circuit breaker. but no AC output is 2. Fault in generator. 2. Contact customer service or authorized service center. available.
  • Page 35: Parts Diagram And Parts List

    PARTS DIAGRAM AND PARTS LIST PARTS DIAGRAM AND PARTS LIST GXS7100iRD GXS7100iRD PARTS DIAGRAM Page 33...
  • Page 36: Parts List

    Parts List Part Number Description Qty. Part Number Description Qty. 20260-06182-00 Engine assy. 34032-00298-00 Bushing 33089-00409-00 Engine mounting plate 20134-00330-00 Wheel assy. 33089-00410-00 Engine mounting plate 30136-00074-00 Fuel tank gasket 30101-00574-00 Hex flange bolt M10*25 30101-00398-00 Hex flange bolt M6*12 34024-00077-00 Metal wire clip 34040-00785-00...
  • Page 37 Parts List Part Number Description Qty. Part Number Description Qty. 34024-00062-00 Clamp 70006-00337-00 Battery charger 34038-00026-00 Carbon canister 30125-00023-00 Hex flange nut M8 30101-00398-00 Hex flange bolt M6*12 33624-00255-00 Support bracket 33624-00256-00 Support bracket 30101-00398-00 Hex flange bolt M6*12 30117-00011-00 Screw 34024-00077-00 Metal wire clip...
  • Page 38: Circuit Diagram

    Circuit Diagram Page 36...
  • Page 39: Warranty

    Warranty Term ups resulting from improper maintenance. A-iPower will provide warranty for any of its products Additional exclusions - this warranty does not cover purchased through any authorized AiPower dealer in wearable parts such as filers, spark plugs, o-rings, North America to the original purchaser and will be batteries etc.
  • Page 40 Warranty limits and Implications and Consequential Damages A-iPower is not obligated to cover any loss of time, use of product, freight cost, or any other incidental or consequential claim from the use of this product. This warranty is in Lieu of all other warranties, express or implied.
  • Page 41 Fontana, CA 92337 USA Phone: 855-888-3598 support@a-ipower.com www.a-ipower.com...
  • Page 42 A-iPOWER WARRANTY REGISTRATION FORM Register your product by emailing this form to support@a-ipower.com or register on-line at: www.a-ipower.com. Registering your product is important , it provides the following protections: 1. You have record of product purchased 2. Customer Service can Better serve you for Warranty related issues...
  • Page 43 Fontana, CA 92337 USA Phone: 855-888-3598 support@a-ipower.com www.a-ipower.com...

Table of Contents

Save PDF