INSTALLER 1
INSTALLER 2
INSTALLER 3
INSTALLER 4
INSTALLER 5

INSTALLER SETUP SCREENS

Accessed by pressing NEXT and DOWN simultaneously for >3 seconds then select
INSTALLER SETUP from the Main Menu.
INSTALLER 1 – Set hardness
Set the inlet water hardness, in grains.
• This screen is only available if set to US units of measurements.
• This screen is not available if System Setup 7 is set to OFF.
Set current day and regen days when set
as a 7 day time clock in System Setup 8.
See next page.
INSTALLER 2 – Set Days Between Regenerations (Day override)
Set day override. 1-28 days between regenerations, or if set to 7 day time clock, see 7 day
setup on next page. OFF will only be displayed if "OFF" is selected in System Setup 8.
• Settings will be based on the type of day override control set in system setup.
• Off will be displayed for units with day override turned off
1 – 28: When set as a 28 day override
• Set the days between regens
1 – 7: When set as a 7 day timeclock
• Turn regen on or off for each specifi c day of the week, Sunday - Saturday
INSTALLER 3 – Set Delayed Regeneration Open Time Hour
• A maximum of 4 regeneration windows can be setup. Setup the open time (hour:miunute)
and close time (hour:minute) for each window.
• Set the delayed time of regeneration, hour (AM / PM toggles at midnight)
INSTALLER 4 – Set Delayed Regeneration Open Time Minute
• Set delayed time of regeneration, minute
INSTALLER 5 – Set Delayed Regeneration Close Time Hour
• Set the delayed time of regeneration, hour (AM / PM toggles at midnight)