Download Print this page

Atp Tools And Materials - Motorola SC 300 Manual

Bts hardware installation, atp and fru procedure
Hide thumbs Also See for SC 300:

Advertisement

ATP Tools and Materials

1
Policy
Test equipment calibration
Test cable calibration
Equipment Warm–up
1-16
To ensure consistent, reliable and repeatable test results, test equipment
meeting the following technical criteria should be used to perform the
ATP on the BTS equipment.
It is the responsibility of the customer to account for any measurement
variances and /or additional losses / inaccuracies that can be introduced
as a result of these substitutions. Before beginning the ATP or
troubleshooting, make sure that the test equipment needed is on hand
and operating properly.
Optimum system performance and capacity depend on regular test
equipment service, calibration, and characterization. Follow the original
equipment manufacture (OEM) recommended maintenance and
calibration schedules closely.
Equipment test cables are very important in the ATP. It is recommended
that the cable calibration be run at every BTS with the test cables
attached. This method compensates for test cable insertion loss within
the test equipment itself. No other allowance for test cable insertion loss
needs to be made during the performance of tests.
Another method is to account for the loss by entering it into the Local
Maintenance Facility (LMF) during the optimization procedure. This
method requires accurate test cable characterization in a lab
environment. The cable should be tagged with the characterization
information prior to field optimization.
After arriving at the a site, the test equipment should be plugged in and
turned on to allow warm up and stabilization to occur for as long as
possible. The following pieces of test equipment must be warmed–up for
a minimum of 60 minutes prior to the ATP.
Communications Test Set
Power Meter
SC 300 BTS Hardware Installation, ATP and FRU Procedures
NOTE
During manual testing, you can substitute supported test
equipment with other test equipment models not supported
by the LMF. However, they must meet the same technical
specifications.
PRELIMINARY
DEC 2000

Advertisement

loading
Need help?

Need help?

Do you have a question about the SC 300 and is the answer not in the manual?

Questions and answers