- Do not touch the spur of the drum unit.
F-1-11
12) Secure the new drum unit in place using a screw
[1].
F-1-12
13) Shift the locking lever [1] of the developing
assembly to the right to lock it in place.
F-1-13
14) Secure the locking lever in place using a screw [1].
F-1-14
15) Close the right door.
16) Fit the waste toner box.
F-1-15
17) Using 2 screws [2], mount the front cover unit [3];
then, fit the face rubber member [1].
At this time, be sure to slide the front cover to the right
so that its claws will match the host machine.