PC with a free USB 2.0 / 3.0 port (IN 5V DC 110mA)
Windows® 10 / 8 / 8.1 / 7
Android device (It needs through a OTG adapter and device supports the OTG function) (With your own OTG adapter)
DEVICE LAYOUT
Left Analog Stick / L3 Button
Back Button
Indicator Light for Channel
Home Button
Detachable Cable Port
Start Button
Action Buttons: A, B, X, Y
Right Analog Stick / R3 Button
SET Button, Sensitivity Setting for Right Stick
OLED Display
PROG Button, Sensitivity Setting for Left Stick
Directional Pad
Multiti-function Buttons: K1, K2
Bumper Button (LB)
Trigger Button (LT)
Multiti-function Buttons: K3, K4, K5, K6
Switch: X-input / Direct-input
Switch: Real Switch ON / OFF
Trigger Button (RT)
Bumper Button (RB)
CONNECTING TO YOUR COMPUTER
CAT 7 Gaming Controller comes with a Detachable USB connection cable. Please connect the Micro USB solid to the controller before connect to the USB A connection.
Plug your CAT 7 gaming controller into the USB port of your device.
The OLED will display "GAMEPAD", whenever CAT 7 connected successfully.
You can switch the mode between the X-input and Direct input via the switch at the back of the controller
The LED indicator channel for the CAT 7 gaming controller.
USING THE LEGENDARY JOYPAD
CAT 7 Gaming Controller supports full time hot plug connection.
You also can access various features through the OLED screen, such as configuring the Multitifunction Triggers and extended Buttons, Back lighting, and more.
SELECTING THE PROFILE OF MODE
CAT 7 gaming controller has 5 profiles which you can store your customized Settings.
Normal
Profile 1
Profile 2
Macro 1
Macro 2
Press the PROG Button to enter the program mode.
Press the up or down button on the D-pad to choose the profile you wish to reset.
Press the PROG Button again to finish the selection.
THE BASIC BUTTONS FOR PROGRAMMABLE SETTING
There are 14 basic Buttons (A, B, X, Y, LB, RB, LT, RT, D-pad, L3, R3) can set into the 6 extended (K1, K2, K3, K4, K5, K6) Buttons for the remappable or macro programmable function.
CONFIGURING THE REMAPPABLE BUTTONS
The 6 extended programmable Buttons (K1, K2, K3, K4, K5, K6) can set the remappable function. It can store up to 2 memory profiles on board at the same time.
Press PROG Button to enter program mode, use the up and down Button on the D-PAD to select Profile 1 or Profile 2 for edit.
Press SET Button to enter Setting mode, the screen shows "program mode"3. While press and hold the extended Button, you can configure:
Press any of the basic Buttons to assign its function to the extended Buttons, then set up will be completed after you release the Buttons.
Press the SET Button to disable the Setting of this extended Buttons; the display shows and back to "Program mode".
Press the SET Button to end configuration and back to the normal "GAMEPAD" state.
CONFIGURING THE MACRO BUTTONS
The 6 extended programmable Buttons (K1, K2, K3, K4, K5, K6) can set for Multi functions. Each defined Buttons can set Max. 14 different actions; the complex number keys count by one action. It can store 2 of memory groups on board and the each group can save 6 macro Settings.
Press PROG Button to enter program mode, use the up and down Button on the D-PAD to select Macro 1 or Macro 2 for edit.
Press SET Button to enter Setting mode, the screen shows "program mode"
While press and hold the extended Button, you can configure:
Press the basic Buttons to assign the macro function to the extended Buttons, then set up will be completed after you release the Buttons.
Press the SET Button and hold the extended Button to disable the Setting; the screen shows back to "Program mode".
Press the SET Button to end configuration and back to the normal "GAMEPAD" state.
CUSTOMISING THE ANALOG TRIGGER SENSITIVITY
There are 4 trigger levels can select. The initial Setting is 100 (lowest Sensitivity 75, 50 or 25 (fully trigger rangeactive, maximum sensitivity)
Press PROG Button to enter program mode, use the up or down Button on the D-pad to select Profile 1 or Profile 2.
Press SET Button to enter Setting mode, the display shows "program mode"
While press and hold the trigger LT (or RT), you can enter the Setting menu
Press the up or down Button on the D-pad to select Sensitivity.
Press the trigger LT (or RT) Button again to exit customization mode. Press the "SET" again to exit the program mode.
CUSTOMISING THE ANALOG STICK SENSITIVITY
When the display shows "GAMEPAD", turn the potentiometer dial to the left or right to adjust the analog Stick Sensitivity.
The display appears the current Sensitivity Setting of both le and right analog Sticks. Turn to the le or right to increase/decrease Sensitivity (-10 minimum Sensitivity / +10 maximum Sensitivity).
ACTIVATING / DEACTIVATING LED ILLUMINATION
The backlight designs on the 4 action Buttons A, B, X, Y.
Press "SET" in "GAMEPAD" mode, the display shows "LightLed On" or "LightLed Off", use the up or down Button on the D-pad to choose the On or Off.
Confirm the change by pressing the "SET" again.
REAR BUTTON (K3-K6) ON/OFF
Switch ON / OFF function to enable / disable 4 rear Buttons.
RESETTING TO DEFAULT
Reset deletes all your Settings and returns to default status.
Press and hold "START" and "BACK" buttons for 5 seconds, until you see the screen displays "Reset?"
Press the "A" button to reset or "SET" to cancel.
To confirm, press the "A" button. The display shows "Resetting..." and all settings will then be deleted.
To cancel, press "SET" button. The display shows "GAMEPAD" and returns to normal state.
SAFETY AND MAINTENANCE
In order to achieve maximum safety while using your device, we suggest you adopt the following guideline.
DO NOT pull out the K3 ~ K6 Buttons, or flip them to the opposite direction.
If you have trouble operating the device properly, try to unplug the device and reset again. Do not attempt to fix the device yourself at anytime.
Do not take apart the device and do not attempt to service it yourself or operate it under abnormal current loads.
Keep your device away from liquid, humidity or moisture. Operate your device only within the specified temperature range.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
This device may not cause harmful interference, and
this device must accept any interference received, including interference that may cause undesired operation.
Need help?
Do you have a question about the C.A.T. 7 and is the answer not in the manual?
Questions and answers