P300 Series - Triplex Ceramic Plunger Pump Operating Instructions/ 16 & 18 mm versions Repair and Service Manual For Models:P316, P317, P319, P322, P323, P325, P328, P329, P332 & P340 Contents: Installation Instructions: page 2 Pump Specifications: page 3 Exploded View:...
Page 2
1. Prior to initial operation, add oil to the crankcase so that oil level is between the two lines on the oil dip- stick. DO NOT OVERFILL. Use Giant oil - P/N 01153 (20W-50 non-detergent motor oil) Crankcase oil should be changed after the first 50 hours of operation, then at regular intervals of 500 hours or less depending on operating conditions.
Page 4
Exploded View - P300 Series - 16 and 18mm...
Page 5
P300 SERIES PARTS LIST A= P317 B= P323 C= P340 D= P316 E= P322 F= P319 G= P325 H= P328 I= P329 J=P332 ITEM PART # DESCRIPTION QTY. ITEM PART # DESCRIPTION QTY. 08326 Crankcase 06542 Wrist Pin 06773 Dipstick Assembly...
Page 6
P300 SERIES REPAIR KITS Plunger Packing Kits Optional Viton Seal Kits P316/P317/P319/P322/ P316/P317/P319/P322/P323/P325 - # 09456 P323/P325/P332 - # 09119 Item Part # Description Qty. Item Part # Description Qty. 07770-0001 O-Ring, Viton 08477 Grooved Seal, Black 07780-0001 O-Ring, Viton...
Page 7
Replace plungers Inlet pressure too high Reduce inlet pressure High Crankcase Wrong Grade of oil Giant oil is recommended Temperature Improper amount of oil in crankcase Adjust oil level to proper amount Preventative Maintenance Check List & Recommended Spare Parts List...
Page 8
REPAIR INSTRUCTIONS - P300 SERIES - 16 & 18 MM VERSIONS NOTE: Always take time to lubricate all metal and nonmetal parts with a light film of oil before reassembly. This step will ensure proper fit, at the same time protecting the pump nonmetal parts (i.e., the elastomers) from cutting and scoring.
Page 9
REPAIR INSTRUCTIONS - P300 SERIES - 16 & 18 MM VERSIONS Remove the pressure 10. Remove the weep grooved 11. Inspect o-rings (#21 rings (#24) and grooved seals (23A) from the seal and 22) and replace as seals (#23) from the valve case (#20).
Page 10
REPAIR INSTRUCTIONS - P300 SERIES - 16 & 18 MM VERSIONS Reassembly sequence of the P300 Series pump 14. If the oil seals (#19) were 15. Place each seal case 16. With the grooved side removed, replace them (#20) with o-rings (#21, 22)
Page 12
1. Five (5) years from the date of shipment for all pumps used in portable pressure washers with NON-SALINE, clean water applications. 2. Two (2) years from the date of shipment for Giant pumps used in car wash applications. 3. One (1) year from the date of shipment for all other Giant industrial and consumer pumps.