flying the vario will beep with the volume that you have set. Remember though, that you can change
the volume during flight with a short press of the red button.
dampingFactor=0.00
Here you can set a damping factor fron 0 up to max 10. As soon as you set a damping factor then
the vario will react slower to changes in altitude.
ClimbToneOnThreshold=0.2
With this setting the vario will begin to beep when the climb rate is higher than 0.2m/s. When you
ClimbToneOnThreshold=-0.5
want to use a thermal sniffer then you can set
for example. In this
case the vario will begin to beep when the sink rate is less than -0.5m/s. In this way you can adjust
the beeping tone so that you know when you're flying in lifting air, despite the fact that you're
actually sinking gently. This can be helpful to find and core thermals in weak conditions.
ClimbToneOffThreshold=0.1
With this setting the vario will stop beeping when the climb rate is below 0.1m/s. You can also use
negative values here, for example -0.51m/s when you use a thermal sniffer.
SinkToneOnThreshold=-3.0
The sink tone will be activated when the sink rate is below -3m/s.
SinkToneOffThreshold=-3.0
The sink tone will be deactivated when the sink rate is less than -3m/s.
tone=-10.00,200,100,100
tone=-3.00,280,100,100
tone=-0.51,300,500,100
tone=-0.50,200,800,5
tone=0.09,400,600,10
tone=0.10,400,600,50
tone=1.16,550,552,52
tone=2.67,763,483,55
tone=4.24,985,412,58
tone=6.00,1234,332,62
tone=8.00,1517,241,66
tone=10.00,1800,150,70
You must define exactly 12 tones. Additional tones will be deleted from the configuration file, and
missing tones will be complemented with values stored in the Eeprom. The tones must be defined
ascending from tone 1 of -10m/s to tone 10m/s of tone 12.