2. WATER FLOW RATE ADJUSTMENT

(1) How to adjust to maximum water flow rate.
Step 1:
Push the Push On-Off Lever and select Wide Shower type on the Shower Head using the Shower Select Button
(refer Figure 1).
Step 2:
Turn "Off" the Main Water Valve.
Step 3:
Turn the Shower Head upward at waist height.
Step 4:
Turn the Water Volume Knob to maximum volume position (refer Figure 2).
Step 5:
Gradually "On" the Main Water Valve and adjust the splashing height (H) of the shower.
It is recomended to adjust the water splashing height (H) at 100 cm ~ 110 cm (approximately 3 L/min).
(If splashing height (H) is too high, hot water temperature will drop because of an excessive flow rate).
Note: 1. Pay attention to shower temperature when reducing the volume of water.
The shower temperature will become very hot if the water flow rate is too low.
2. Water Volume Knob is at maximum position at this stage (refer Step 4).
Please adjust it to suitable flow rate using the Water Volume Knob by turning it anticlockwise.
Spot Shower
Press
Normal Shower
Wide Shower
Shower Select Button

3. MAINTENANCE

Switch "OFF" the Miniature Circuit Breaker (MCB)
before service.
(1) Main Body cleaning.
Be sure to switch "OFF" the Miniature Circuit Breaker beforehand.
1) Clean it with moist cloth.
2) Never use benzene, thinner, detergent, bleach, etc.
3) Do not spray water to the unit, not put wet towels on it.
4) Make sure to use suitable cloth to clean the Front Plate surface
to avoid scratch.
(2) Shower Head cleaning.
1) Turn the Shower Plate anticlockwise and remove it from the Shower Head
with hand.
2) Clean the Shower Plate's holes by using a soft brush from time to time.
(Recommended once a week).
CAUTION
(3) Filter Unit Cleaning (Filter Unit is fixed to Filter Knob)
Clean the Filter of the Filter Unit with water once a week.
Clean the Filter Unit when hot water is not drawn normally.
Dismantle, cleaning and assemble of Filter Unit
Lo
Med
Close the Main Water Valve.
1
Off
Hi
Power Selector
ELB Test
Push On-Off
ELB Reset
Push Up
DH-4MS1
Water Volume Knob
Main Water Valve
Filter Knob
Water Volume Knob
FILTER
CLEANING
Figure 1
Figure 2
WARNING
Take care do not damage the holes of the Shower Plate during the cleaning.
The Rubber Packing shall be set on the Shower Head before fixing back the Shower Plate
to Shower Head. Do not remove other parts other than Shower Plate and Rubber Packing.
- 6 -
Push On-Off Lever
H = 100 cm ~ 110 cm
Waist Height
Rubber Packing
Shower Plate
Turn Water Volume Knob clockwise if it is blocking the Filter Knob.
2
Turn the Filter Knob anticlockwise and pull it out.
FILTER
CLEANING
Lo
Med
Water Volume Knob
Off
Hi
Power Selector
ELB
ELB Test
ELB Reset
Push On-Off
DH-4MS1
Push Up
Main Water
Valve
Floor
Shower
Head
Soft Brush