Page 2
STANLEY Healthcare. Trademark Acknowledgements AeroScout is a trademark of Stanley Black & Decker. Other brand products and service names are trademarks or registered trademarks of their respective holders. Below is a partial listing of other trademarks or registered trademarks referenced herein: Cisco™...
The EX5200 Exciter extends the suite to provide robust and sophisticated RFID detection capabilities. The EX5200 Exciter triggers Tags as they pass through a chokepoint or as they approach the Exciter. Tags in turn transmit a message to either the AeroScout Location Receivers or to compatible Access Points within range.
EX5200 Exciter Deployment Guide Exciter Applications and Industry Examples Theft Prevention Healthcare organizations or enterprises with expensive and mission-critical equipment can tag valuable assets that are intended to remain within a specified area. The AeroScout System can track the location of such items and trigger an alert when they pass through an exit point or enter a restricted area.
EX5200 Exciter Deployment Guide Exciter Features RFID Detection of STANLEY Healthcare Tags The Exciter triggers Tags to transmit as they pass through a defined area, within a range of up to 6.5 meters (21.3 feet). This is typically enough to cover door or gate areas.
EX5200 Exciter Deployment Guide The Exciter can store messages on the Tag for subsequent transmission. The stored messages can subsequently be triggered by other Exciters, enabling sophisticated process control functions. The Exciter can trigger a Tag to: Transmit up to 15 bytes of data sent to it by the Exciter •...
EX5200 Exciter Deployment Guide LED Status Indicators The EX5200 has a single LED that changes color based on the Exciter's status as follows: Green (continuous): The Exciter is transmitting and functioning correctly • Green (Blinking) During Firmware upgrade the Exciter blinks green until the •...
EX5200 Exciter Deployment Guide Exciter Connector Panel The EX5200 Exciter has four connectors and two switches inside the back panel. Figure 4: EX5200R Connector Wiring (#1) Ethernet LAN Connection: RJ-45 connector. In a configuration with a physical Ethernet cable connection to the LAN, the network cable is attached here.
Page 11
EX5200 Exciter Deployment Guide (#3) Chain IN: RJ-45 connector. This connector is used for receiving data from chained Exciters. The Chain IN port is also used to set the Exciter IP via the Exciter Manager Application using a special 10-pin RJ45 to DB9 serial cable (AeroScout SKU EXM-1000, or part of the Hardware Management kit).
The following is a brief summary of available powering and networking options: Usage Option Description Single EX5200– not EX5200 can be used as standalone devices that function connected to a independently without any network connection. In this network case, you only need to connect the Exciter to the power supply.
CAT-5/6 Ethernet cable from the PoE switch to the Exciter’s LAN connector. This supplies both the power and the network connection. PoE standard 802.3af class 0 allows power for a single EX5200 Exciter. Note When using PoE with the other chained Exciters, a PoE connection must be made to every second Exciter in the chain.
EX5200 Exciter Deployment Guide 110/220 VAC to 48 VDC PoE Single-Port Injector The PoE Single Port Injector converts 110/220 VAC to 48 VDC. In addition, it can receive a network connection and you can run a single cable to the Exciter’s LAN connector, thus supplying both power and network connectivity.
EX5200 Exciter Deployment Guide Power Connection Summary The following table summarizes the power connection options: Power Supply Input Output Maximum Available Maximum # Current of Exciters Power with One Source PoE single port 100-240 48 VDC 0.32 A(1) 15.4 W...
The first Exciter in the chain, directly connected to the LAN, is designated the “Master”. Other Exciters are designated “Slave”. EX5200 Exciters can act as either Master or Slave Exciters. The Master Exciter is connected to the first Slave Exciter as follows: Master Chain OUT to Slave Chain IN.
Page 17
EX5200 Exciter Deployment Guide The Termination Switch of the Master Exciter and the last Slave Exciter in the chain must be set to On (o-o). On the other Slave Exciters, it must be set to Off (-o o-). The Master/Slave configuration is set via System Manager.
EX5200 Exciter Deployment Guide Resetting the Exciter IP Address You can reset the Exciter’s IP address to the factory default value. The default IP address is 192.168.1.178. To do so, press the IP Reset button with a ballpoint pen for 5 seconds.
EX5200 Exciter Deployment Guide Connecting an External LF Antenna The External LF Antenna device is designed to extend the Exciter's LF coverage. The two devices communicate via a standard CAT5 cable connection. Connect the Exciter's Chaining OUT connector to the external LF device's IN connector.
EX5200 Exciter Deployment Guide Mounting the Exciter Position and mount each EX5500 Controller in the site according to the site survey recommendations. Fixing the Controller to a Floating Ceiling: Attach the device to the false ceiling using the ceiling mounts located on the bottom casing of the device.
Page 21
Anchor the screws into the wall, leaving 10mm of each of the screws exposed. Use appropriate screws and or anchoring plugs. Mount the Controller with the STANLEY Healthcare logo facing up, onto the 4 screws. The Controller's back panel has 4 mounting brackets for this...
EX5200 Exciter Deployment Guide Mounting the Controller using the Exciter Mounting Clip To mount the Controller in the center of a ceiling tile using the Exciter Mounting Clip, Figure 12, you must order an EX5500 Mounting Clip Kit, sold separately (SKU: EXAC-141). The Kit can be used to mount the Controller in deployments where mounting on the ceiling grid is not possible.
Page 23
EX5200 Exciter Deployment Guide Figure 14: Mountng Clip with Screws and Spacers Measure and mark the required positions of the mounting screws on the ceiling tile. Drill holes in the ceiling tile at the marked positions and refit the ceiling tile.
Page 24
EX5200 Exciter Deployment Guide Figure 16: Screwing the Mounting Adapter to the Spacers of the Mounting Clip Attach the Controller to the Mounting Adapter by aligning the clips on the back of the Controller casing with the four brackets on the adapter.
Page 25
EX5200 Exciter Deployment Guide Figure 18: Releasing the Controller from the Mounting Adapter...
Page 26
EX5200 Exciter Deployment Guide Appendix A: Exciter and Accessories Product Description EX5200 EX-5200 EX5200 Exciter includes 48 VDC input, Exciter Ethernet and PoE interface. Wall mounting plate included. Power supply not included. Exciter APD-047-U (US) AC/DC adaptor 45W 48 V/1.0A 90-264VAC for...
Page 27
EX5200 Exciter Deployment Guide Appendix B: Exciter Specifications Physical and Mechanical Dimensions: 245mm X 200mm X 60mm (9.6in x 7.9in x 2.4in) • Weight: 865g (31oz) • Housing: Polycarbonate and ABS • Coverage Adjustable coverage range between 1.5m (4.9 ft.) and 6.5m (21.3 ft.) by •...
Page 28
FCC Compliance Statement This device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in residential installations. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio and television reception.
Page 29
Security & Protection, Safety, Environmental Monitoring, Clinical Operations & Workflow, and Supply Chain & Asset Management. These solutions are complemented by consulting, training, implementation and integration services. STANLEY Healthcare is proud to be part of Stanley Black & Decker, Inc. For more information, visit: www.stanleyhealthcare.com...
Need help?
Do you have a question about the EX5200 and is the answer not in the manual?
Questions and answers